# FHWA-HIF-17-004, Example 10.2.1 · Geosynthetic MSE wall

Geosynthetic MSE wall, Example 10.2.1 of Leshchinsky et al. (2016), solved in Rischio and compared with the source's answers.

SourceManual

Leshchinsky, D., Leshchinsky, O., Zelenko, B., & Horne, J. (2016). Limit Equilibrium Design Framework for MSE Structures with Extensible Reinforcement (FHWA-HIF-17-004). Federal Highway Administration. Example 10.2.1, p. 67–69.

ID `fhwa-hif-17-004-10-2-1`

[Open in the studio](https://studio.rischio.io/examples/fhwa-hif-17-004-10-2-1?utm_source=rischio.io&utm_medium=website&utm_content=docs-example) A copy, in your account [Open the PDF](https://www.fhwa.dot.gov/engineering/geotech/pubs/hif17004.pdf)

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to [hello@rischio.io](mailto:hello@rischio.io).

## The problem

What the source calculates: largest tension in the reinforcement, Tmax and allowable strength of the geosynthetic, Tal (the report's LTDS). Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure 10-1, p. 67.

## Source vs Rischio

|  | Source | Rischio | Difference |
| --- | --- | --- | --- |
| Largest tension in the reinforcement, Tmax | 1 343 lb/ft | 1 343 lb/ft | 0.0 % |
| Allowable strength of the geosynthetic, Tal (the report's LTDS) | 2 016 lb/ft | 2 016 lb/ft | 0.0 % |

Opened in the studio under AASHTO LRFD 10th (2024), the model fails at least one check.

The example sets the embedment to zero for simplicity, so Rischio's minimum embedment check doesn't pass. Its face leans 8° and the model's is vertical, which doesn't change the reinforcement loads: the example computes them for a vertical face.

## How it's calculated

-   [MSE walls → How Rischio checks an MSE wall: each layer's load by AASHTO's method for its reinforcement, its rupture and pullout, and the block outside.](https://rischio.io/docs/retaining-wall/theory/mse/)
-   [Equations → Every step of the calculation, in order.](https://rischio.io/docs/retaining-wall/equations/)
-   [Retaining walls in Rischio → The tool: what it checks, and its calculation report.](https://rischio.io/retaining-wall/)

## Nearest examples

-   [FHWA-NHI-00-043, Example 4.6 · Steel strip wall, ASD Elias et al. (2001): eccentricity, e](https://rischio.io/docs/examples/fhwa-nhi-00-043-4-6/)
-   [FHWA-NHI-00-043, Example 4.7 · Modular block geogrid wall Elias et al. (2001): factor of safety for bearing capacity](https://rischio.io/docs/examples/fhwa-nhi-00-043-4-7/)
-   [FHWA-NHI-07-071, Example 7.9 · Precast panel MSE wall Tanyu et al. (2008): factored rupture resistance, φ Tal Rc](https://rischio.io/docs/examples/fhwa-nhi-07-071-7-9/)

---

Source: https://rischio.io/docs/examples/fhwa-hif-17-004-10-2-1/
