MSE wall with geogrids, Example C1 of Federal Highway Administration (2023), solved in Rischio. Largest reinforcement strain, εrein: 0.017 (source: 0.017).

SourceManual

Taylor, Collin, Boyle, Fishman & Han (2023). Design and Construction of Mechanically Stabilized Earth (MSE) Walls (FHWA-HIF-24-002). Federal Highway Administration. Example C1, p. C-37.

ID `fhwa-hif-24-002-c1-geogrid`

[Open in the studio](https://studio.rischio.io/examples/fhwa-hif-24-002-c1-geogrid?utm_source=rischio.io&utm_medium=website&utm_content=docs-example) A copy, in your account [Open the PDF](https://www.fhwa.dot.gov/engineering/geotech/pubs/hif24002.pdf)

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to [hello@rischio.io](mailto:hello@rischio.io).

## The problem

What the source calculates: rupture capacity/demand ratio at layers 9 to 12, CDR and largest reinforcement strain, εrein. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure C1-1, p. C-2.

## Source vs Rischio

|  | Source | Rischio | Difference |
| --- | --- | --- | --- |
| Rupture capacity/demand ratio at layers 9 to 12, CDR | 2.18 | 2.18 | +0.2 % |
| Largest reinforcement strain, εrein | 0.017 | 0.017 | +0.6 % |

Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.

## How it's calculated

-   [MSE walls → How Rischio checks an MSE wall: each layer's load by AASHTO's method for its reinforcement, its rupture and pullout, and the block outside.](https://rischio.io/docs/retaining-wall/theory/mse/)
-   [Equations → Every step of the calculation, in order.](https://rischio.io/docs/retaining-wall/equations/)
-   [Retaining walls in Rischio → The tool: what it checks, and its calculation report.](https://rischio.io/retaining-wall/)

## Nearest examples

-   [FHWA GEC 11 (2023), Example C1 · MSE wall with steel strips Federal Highway Administration (2023): pullout capacity/demand ratio at layer 8 (z = 18.75 ft) by the Simplified Method, CDR](https://rischio.io/docs/examples/fhwa-hif-24-002-c1/)
-   [FHWA-HIF-17-004, Example 10.2.1 · Geosynthetic MSE wall Leshchinsky et al. (2016): allowable strength of the geosynthetic, Tal (the report's LTDS)](https://rischio.io/docs/examples/fhwa-hif-17-004-10-2-1/)
-   [FHWA-NHI-00-043, Example 4.6 · Steel strip wall, ASD Elias et al. (2001): eccentricity, e](https://rischio.io/docs/examples/fhwa-nhi-00-043-4-6/)

---

Source: https://rischio.io/docs/examples/fhwa-hif-24-002-c1-geogrid/