# FHWA-NHI-16-064, Example D.21 · H-pile column after scour

H-pile column after scour, Example D.21 of Federal Highway Administration (2016), solved in Rischio and compared with the source's answers.

SourceManual

Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.21, p. 93–94.

ID `fhwa-nhi-16-064-d21`

[Open in the studio](https://studio.rischio.io/examples/fhwa-nhi-16-064-d21?utm_source=rischio.io&utm_medium=website&utm_content=docs-example) A copy, in your account [Open the PDF](https://www.fhwa.dot.gov/engineering/geotech/pubs/gec12/nhi16009_v3.pdf)

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to [hello@rischio.io](mailto:hello@rischio.io).

## The problem

What the source calculates: nominal axial resistance at the design flood (Strength V), Pn, nominal axial resistance at the check flood (Extreme Event II), Pn and factored axial resistance at the design flood (Strength V), Pr. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure D-39, p. 98.

## Source vs Rischio

|  | Source | Rischio | Difference |
| --- | --- | --- | --- |
| Nominal axial resistance at the design flood (Strength V), Pn | 1 043 kips | 1 045 kips | +0.2 % |
| Nominal axial resistance at the check flood (Extreme Event II), Pn | 999 kips | 1 001 kips | +0.3 % |
| Factored axial resistance at the design flood (Strength V), Pr | 521 kips | 523 kips | +0.3 % |

Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.

The model carries the load on the most loaded pile (Tables D-58 to D-61): its permanent part as dead load, and the rest of its Service I load, the traffic and the cap's moments, which the manual doesn't separate, as live load. Rischio factors it at Strength I to 305 kips, on the safe side of the manual's Strength V, 257 kips, which takes the traffic at 1.35 and adds the wind.

## How it's calculated

-   [Structural resistance → How Rischio checks a pile as a structural member: steel by AASHTO Section 6, a drilled shaft with its cage by Section 5, in axial load, bending and shear.](https://rischio.io/docs/deep-foundation/theory/structural/)
-   [Equations → Every step of the calculation, in order.](https://rischio.io/docs/deep-foundation/equations/)
-   [Piles in Rischio → The tool: what it checks, and its calculation report.](https://rischio.io/deep-foundation/)

## Nearest examples

-   [FHWA-NHI-16-064, Example D.14 · H-pile group, lateral load Federal Highway Administration (2016): largest moment in the pile, Muy](https://rischio.io/docs/examples/fhwa-nhi-16-064-d14/)
-   [FHWA-NHI-16-064, Example D.22.1 · H-pile, toe in clay Federal Highway Administration (2016): nominal resistance, Rn](https://rischio.io/docs/examples/fhwa-nhi-16-064-d22-1-clay-toe/)