# FHWA-NHI-16-064, Example D.22.1 · H-pile, toe in clay

H-pile, toe in clay, Example D.22.1 of Federal Highway Administration (2016), solved in Rischio. Nominal resistance, Rn: 47.6 kips (source: 47.2 kips).

SourceManual

Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.22.1, p. 99–100.

ID `fhwa-nhi-16-064-d22-1-clay-toe`

[Open in the studio](https://studio.rischio.io/examples/fhwa-nhi-16-064-d22-1-clay-toe?utm_source=rischio.io&utm_medium=website&utm_content=docs-example) A copy, in your account [Open the PDF](https://www.fhwa.dot.gov/engineering/geotech/pubs/gec12/nhi16009_v3.pdf)

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to [hello@rischio.io](mailto:hello@rischio.io).

## The problem

What the source calculates: toe resistance in the clay, Rp, shaft resistance, Rs and nominal resistance, Rn. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure D-39, p. 98.

## Source vs Rischio

|  | Source | Rischio | Difference |
| --- | --- | --- | --- |
| Toe resistance in the clay, Rp | 28.6 kips | 28.7 kips | +0.3 % |
| Shaft resistance, Rs | 18.6 kips | 18.9 kips | +1.5 % |
| Nominal resistance, Rn | 47.2 kips | 47.6 kips | +0.8 % |

Opened in the studio under AASHTO LRFD 10th (2024), the model fails at least one check.

The manual's values come from the DrivenPiles program. Rischio reads Nordlund's coefficients for the gravel off AASHTO's charts, so its shaft resistance can differ from the program's by up to 2 %. The model carries the load on the most loaded pile (Tables D-58 to D-61): its permanent part as dead load, and the rest of its Service I load, the traffic and the cap's moments, which the manual doesn't separate, as live load. Rischio factors it at Strength I to 305 kips, on the safe side of the manual's Strength V, 257 kips, which takes the traffic at 1.35 and adds the wind. At 10 ft the pile carries neither, as in the manual, which drives it to 40 ft (Table D-63).

## How it's calculated

-   [Shaft resistance → How Rischio adds up a pile's shaft, stratum by stratum: a driven pile by Tomlinson's α in clay and Nordlund's method in sand, a drilled shaft by FHWA GEC 10.](https://rischio.io/docs/deep-foundation/theory/shaft/)
-   [Toe resistance → How Rischio calculates a pile's toe: a driven pile's by Nordlund's method in sand, 9 cu in clay, and a drilled shaft's by FHWA GEC 10.](https://rischio.io/docs/deep-foundation/theory/toe/)
-   [Equations → Every step of the calculation, in order.](https://rischio.io/docs/deep-foundation/equations/)
-   [Piles in Rischio → The tool: what it checks, and its calculation report.](https://rischio.io/deep-foundation/)

## Nearest examples

-   [FHWA-NHI-16-064, Example D.21 · H-pile column after scour Federal Highway Administration (2016): factored axial resistance at the design flood (Strength V), Pr](https://rischio.io/docs/examples/fhwa-nhi-16-064-d21/)
-   [FHWA-NHI-16-064, Example D.22.1 · H-pile through clay Federal Highway Administration (2016): toe resistance, Rp](https://rischio.io/docs/examples/fhwa-nhi-16-064-d22-1/)
-   [FHWA-NHI-06-089, Example 9-2 · Precast pile in silty sand Samtani & Nowatzki (2006): ultimate capacity, Qu](https://rischio.io/docs/examples/fhwa-nhi-06-089-9-2/)

---

Source: https://rischio.io/docs/examples/fhwa-nhi-16-064-d22-1-clay-toe/