# FHWA-NHI-16-064, Example D.9 · H-pile structural resistance

H-pile structural resistance, Example D.9 of FHWA-NHI-16-064, solved in Rischio. Factored axial resistance, Pr: 546 kips (source: 544 kips).

SourceManual

Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.9, p. 21–22.

ID `fhwa-nhi-16-064-d9`

[Open in the studio](https://studio.rischio.io/examples/fhwa-nhi-16-064-d9?utm_source=rischio.io&utm_medium=website&utm_content=docs-example) A copy, in your account [Open the PDF](https://www.fhwa.dot.gov/engineering/geotech/pubs/gec12/nhi16009_v3.pdf)

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to [hello@rischio.io](mailto:hello@rischio.io).

## The problem

What the source calculates: nominal axial resistance, Pn and factored axial resistance, Pr. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure D-7, p. 26.

## Source vs Rischio

|  | Source | Rischio | Difference |
| --- | --- | --- | --- |
| Nominal axial resistance, Pn | 1 088 kips | 1 093 kips | +0.4 % |
| Factored axial resistance, Pr | 544 kips | 546 kips | +0.4 % |

Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.

## How it's calculated

-   [Structural resistance → How Rischio checks a pile as a structural member: steel by AASHTO Section 6, a drilled shaft with its cage by Section 5, in axial load, bending and shear.](https://rischio.io/docs/deep-foundation/theory/structural/)
-   [Equations → Every step of the calculation, in order.](https://rischio.io/docs/deep-foundation/equations/)
-   [Piles in Rischio → The tool: what it checks, and its calculation report.](https://rischio.io/deep-foundation/)

## Nearest examples

-   [FHWA-NHI-16-064, Example D.10.1, 30 ft · H-pile in sand Federal Highway Administration (2016): nominal resistance, Rn](https://rischio.io/docs/examples/fhwa-nhi-16-064-north-abutment-30ft/)
-   [FHWA-NHI-16-064, Example D.10.1, 45 ft · H-pile to gravel Federal Highway Administration (2016): shaft resistance, Rs](https://rischio.io/docs/examples/fhwa-nhi-16-064-north-abutment-45ft/)
-   [FHWA-NHI-06-089, Example 9-2 · Precast pile in silty sand Samtani & Nowatzki (2006): ultimate capacity, Qu](https://rischio.io/docs/examples/fhwa-nhi-06-089-9-2/)

---

Source: https://rischio.io/docs/examples/fhwa-nhi-16-064-d9/