# FHWA GEC 10 (2018), Example 9.3.3.3.4 · Service deflection

Service deflection, Example 9.3.3.3.4 of Federal Highway Administration (2018), solved in Rischio. Deflection at the head, x0: 0.07 in (source: 0.07 in).

SourceManual

Brown, Turner, Castelli & Loehr (2018). Drilled Shafts: Construction Procedures and Design Methods (FHWA-NHI-18-024). Federal Highway Administration. Example 9.3.3.3.4, p. 9-27.

ID `fhwa-nhi-18-024-9-3-3-3-4-service`

[Open in the studio](https://studio.rischio.io/examples/fhwa-nhi-18-024-9-3-3-3-4-service?utm_source=rischio.io&utm_medium=website&utm_content=docs-example) A copy, in your account [Open the PDF](https://www.fhwa.dot.gov/engineering/geotech/nhi18024.pdf)

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to [hello@rischio.io](mailto:hello@rischio.io).

## The problem

What the source calculates: deflection at the head, x0. Its problem, as Rischio's editor opens it in free mode:

The model, as the editor draws it. In the source: Figure 9-21, p. 9-24.

## Source vs Rischio

|  | Source | Rischio | Difference |
| --- | --- | --- | --- |
| Deflection at the head, x0 | 0.07 in | 0.07 in | +0.6 % |

Opened in the studio in free mode, the model meets the limits it carries.

The manual's final service deflection, 0.13 in, takes the cracked section's stiffness, which Rischio doesn't model; 0.07 in is its run with the linear elastic shaft, the one Rischio solves. Both are within the 1/2 in the problem allows.

## How it's calculated

-   [Lateral load → How Rischio calculates a pile or a pile group under a lateral load: a beam-column on each stratum's p–y curves, a group's rows by their p-multipliers.](https://rischio.io/docs/deep-foundation/theory/lateral/)
-   [Equations → Every step of the calculation, in order.](https://rischio.io/docs/deep-foundation/equations/)
-   [Piles in Rischio → The tool: what it checks, and its calculation report.](https://rischio.io/deep-foundation/)

## Nearest examples

-   [FHWA GEC 10 (2018), Example 9.3.3.3.4 · Longer shaft Federal Highway Administration (2018): largest bending moment, Mmax](https://rischio.io/docs/examples/fhwa-nhi-18-024-9-3-3-3-4-25-ft/)
-   [FHWA GEC 10 (2018), Example 9.3.3.3.4 · Shaft, lateral load Federal Highway Administration (2018): largest bending moment, Mmax](https://rischio.io/docs/examples/fhwa-nhi-18-024-9-3-3-3-4/)
-   [FHWA-NHI-16-064, Example D.14 · H-pile group, lateral load Federal Highway Administration (2016): largest moment in the pile, Muy](https://rischio.io/docs/examples/fhwa-nhi-16-064-d14/)

---

Source: https://rischio.io/docs/examples/fhwa-nhi-18-024-9-3-3-3-4-service/