# Design criteria and limits

How Rischio judges each check: free mode, where your limits give the verdict and the manuals' limits sit beside it, or a design code, AASHTO LRFD.

Every check gives a value: a factor of safety, an eccentricity, a settlement. Whether it passes depends on the model’s mode, which is free mode unless a design code is chosen. With nothing selected, the editor shows it under **Design code**.

## Free mode

Free mode has no design code. The methods are the designer’s, each left at its default or chosen, and each check gives its factor of safety, unfactored, or its quantity. A load’s dead and live parts are added; a footing’s and a pile’s live parts are each in or out, whichever governs each check, as a wall’s live line loads are ([Bearing capacity](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/#loads-that-come-and-go), [piles](https://rischio.io/docs/deep-foundation/theory/#loads-that-come-and-go)). Partial factors belong to a code, so free mode has none.

A check has a verdict only where the designer set a limit for it. Without one it shows its value and no verdict, and the results read **No limits set**. With some limits set, the verdict counts the checks that have one and says how many have none. The check that governs is the one with the smallest margin among those with a limit.

Beside each check, the limit the US manuals ask (FHWA, USACE, and Das & Sivakugan where the manuals are silent) is shown as a reference, with its source and section. A reference never gives the verdict, and the calculation report leaves it out: the report prints the designer’s limits only, under “No design code: methods chosen by the designer”.

### Limits the model sets itself

Two limits come from the model, not from anyone’s choice, and judge in every mode: an open channel’s [bank-full capacity](https://rischio.io/docs/open-channel/theory/capacity/), and a retaining wall’s resultant within its base under an earthquake, $e \le B/2$. Past it the wall tips over whatever the code says. They read **The model’s own limit** and can’t be edited.

## Set a limit

In **Results**, open a check: its **Limit** field reads **None** until a value is typed. The references under it each have **Use**, which takes that value as the limit. A limit of the designer’s reads **yours** on the check without opening it, and **Remove** takes it away. With nothing selected, **Properties** lists the model’s limits under **Your limits**.

A factor of safety, a settlement, a deflection, an eccentricity and a channel’s freeboard can take a limit. An eccentricity’s limit is a length in metres; the manuals’ $B/6$ ($L/6$ for an MSE wall) stays beside it as a reference.

A model written by an agent or through the [MCP server](https://rischio.io/docs/ai/mcp/) sets them in `design.limits`, by the check’s id:

```
"design": { "code": "free_mode", "limits": { "sliding": 1.5, "bearing": 3, "settlement": 0.025 } }
```

## Design codes

A design code brings its own methods, factors and limits, and gives every check a verdict. Rischio has [AASHTO LRFD, 10th edition (2024)](https://rischio.io/docs/reference/aashto-lrfd/), for footings, concrete and MSE retaining walls, piles and drilled shafts. Each check is then $\phi R_n / \Sigma\gamma_i Q_i \ge 1$, with the factor of safety without load or resistance factors beside it as a reference (**Unfactored**). The designer can edit a check’s $\phi$, and the limits AASHTO leaves open (a footing’s settlement, a pile head’s deflection, FHWA’s 25 mm under the code); an edited one reads **edited**, with the code’s value beside it, and **Reset** brings that back. The check that governs is again the one with the smallest margin, with one exception: a cover to a cantilever’s bars, a rule of detailing whose default sits at AASHTO’s least, governs only when it fails.

A code leaves out what it has no factor for: those methods don’t appear in their row’s menu under it, and a model that already had one keeps it, with an error in its field that says why. The open channel, which the code doesn’t cover, has no **Design code**: the limits you give it judge it, as free mode’s do.

Every new model starts in the mode chosen in **Settings**, under **New models start in**, however it’s made: by hand, from a template, by the AI or by an agent. Each model can change it in the editor.

## Methods by the data

A method field the data decide starts at **By the data**: the engine takes the method the data call for, and the section says which one, why and how close the data are to switching it, without opening anything (for instance, *Short heel: the heel measures 2.50 m; Rankine asks 3.19 m*). Results says it too, with the checks it moves ([Read the results](https://rischio.io/docs/studio/results/#the-methods)). What the designer chooses instead is computed as chosen, or refused at its field with the reason; it never switches in silence. Under AASHTO the same rules are the code’s own.

| Tool | Field | By the data | Or the designer’s |
| --- | --- | --- | --- |
| Retaining wall | Earth pressure | Rankine on the vertical through the heel over a long heel; Coulomb on the wall’s back over a short heel or none (AASHTO C3.11.5.3) | Rankine or Coulomb; in free mode, Rankine with cohesion over a level backfill, never by the data and not under AASHTO ([Earth pressure](https://rischio.io/docs/retaining-wall/theory/earth-pressure/#rankine-with-cohesion)) |
| MSE wall | Reinforcement load | The Coherent Gravity Method for steel strips; the Stiffness Method for a geosynthetic with its stiffness $J$; the Simplified Method for one without it (AASHTO 11.10.6.2.1) | The Simplified Method for any; the Coherent Gravity Method for steel; the Stiffness Method for a geogrid or a geotextile with its $J$ |

A footing’s methods each have a default instead: its bearing equation is the design code’s, Meyerhof’s general equation in free mode and Vesic’s general equation under AASHTO, its Eq. 10.6.3.1.2a-1 ([Bearing capacity](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/#ultimate-bearing-capacity)), and its immediate settlement is the elastic one, with Schmertmann’s as the designer’s choice ([Settlement](https://rischio.io/docs/shallow-foundation/theory/settlement/)).

## Retaining walls

| Check | Rule | Usual limit |
| --- | --- | --- |
| 
Sliding

The wall pushed along its base

$FS = \frac{R}{\Sigma H}$

 | $FS = \frac{R}{\Sigma H}$ | $\ge 1.5$ |
| 

Eccentricity

The resultant inside the middle third of the base

$e$

 | $e$ | $\le \frac{B}{6}$ |
| 

Bearing capacity

The ground under the base giving way

$FS = \frac{q_n}{q_{eq}}$

 | $FS = \frac{q_n}{q_{eq}}$ | $\ge 3.0$ |
| 

Bearing pressure

The pressure under the base against your soil study's allowable one: the edge pressure (an MSE block's uniform one), or under AASHTO the uniform one at the service limit state

$q_{max},\; \sigma_v$

 | $q_{max},\; \sigma_v$ | $\le q_a$ |
| 

Gabion levels

Each level sliding on the one below, with its resultant inside the middle third

$e,\; FS = \frac{R}{\Sigma H}$

 | $e,\; FS = \frac{R}{\Sigma H}$ | $\le \frac{B}{6},\; \ge 1.5$ |
| 

Stem, toe and heel

A cantilever's bars by AASHTO LRFD, after the geotechnics: bending, least steel and shear, with the bars' spacing and cover as detailing rules

$\frac{M_r}{M_u},\; \frac{V_r}{V_u}$

 | $\frac{M_r}{M_u},\; \frac{V_r}{V_u}$ | $\ge 1.0$ |

The limits the manuals ask, shown beside each check in free mode:

| Check | Reference | Source |
| --- | --- | --- |
| 
Sliding

FHWA GEC-6 §5.4

 | $\ge 1.5$ | FHWA GEC-6 §5.4 |
| 

Bearing capacity

FHWA GEC-6 §5.2.6

 | $\ge 3.0$ | FHWA GEC-6 §5.2.6 |
| 

Settlement

FHWA GEC-6 §8.3.1

 | $\le 0.025\,\mathrm{m}$ | FHWA GEC-6 §8.3.1 |
| 

Sliding under the earthquake

Under an earthquake

FHWA GEC 3, §11.5.1, p. 11-29: C/D ≥ 1.0 on unfactored forces

 | $\ge 1.0$ | FHWA GEC 3, §11.5.1, p. 11-29: C/D ≥ 1.0 on unfactored forces |
| 

Bearing capacity under the earthquake

Under an earthquake

None beside it: FHWA GEC 3, §11.5.1 asks 0.67 qn > σv,max, the linear peak at the toe (Eq. 11-27, p. 11-30), where this ratio is qn over the uniform pressure on B′

 |  | None beside it: FHWA GEC 3, §11.5.1 asks 0.67 qn > σv,max, the linear peak at the toe (Eq. 11-27, p. 11-30), where this ratio is qn over the uniform pressure on B′ |
| 

Reinforcement rupture under the earthquake

MSE, under an earthquake, steel strips

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.82

 | $\ge 1.364$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.82 |
| 

Reinforcement pullout under the earthquake

MSE, under an earthquake, steel strips

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5

 | $\ge 1.125$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5 |
| 

Connection under the earthquake

MSE, under an earthquake, steel strips

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.82

 | $\ge 1.364$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.82 |
| 

Reinforcement rupture under the earthquake

MSE, under an earthquake, steel grids

FHWA-NHI-00-043, §2.7.c: 75 % of the static 2.08

 | $\ge 1.563$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 2.08 |
| 

Reinforcement pullout under the earthquake

MSE, under an earthquake, steel grids

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5

 | $\ge 1.125$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5 |
| 

Connection under the earthquake

MSE, under an earthquake, steel grids

FHWA-NHI-00-043, §2.7.c: 75 % of the static 2.08

 | $\ge 1.563$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 2.08 |
| 

Reinforcement rupture under the earthquake

MSE, under an earthquake, geosynthetics

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5

 | $\ge 1.125$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5 |
| 

Reinforcement pullout under the earthquake

MSE, under an earthquake, geosynthetics

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5

 | $\ge 1.125$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5 |
| 

Connection under the earthquake

MSE, under an earthquake, geosynthetics

FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5

 | $\ge 1.125$ | FHWA-NHI-00-043, §2.7.c: 75 % of the static 1.5 |
| 

Sliding under the earthquake

MSE, under an earthquake

FHWA-HIF-24-002, §6.1.1, Step 8, p. 227: CDR ≥ 1.0 on the nominal weight

 | $\ge 1.0$ | FHWA-HIF-24-002, §6.1.1, Step 8, p. 227: CDR ≥ 1.0 on the nominal weight |
| 

Bearing capacity under the earthquake

MSE, under an earthquake

None beside it: FHWA-HIF-24-002 checks it on Extreme Event I's factored loads (Step 11, p. 229), and free mode's is unfactored

 |  | None beside it: FHWA-HIF-24-002 checks it on Extreme Event I's factored loads (Step 11, p. 229), and free mode's is unfactored |
| 

Rupture of the reinforcement

MSE, Simplified Method, steel strips

FHWA-NHI-00-043, §2.7.c: 0.55 Fy

 | $\ge 1.818$ | FHWA-NHI-00-043, §2.7.c: 0.55 Fy |
| 

Reinforcement connection to the facing

MSE, Simplified Method, steel strips

FHWA-NHI-00-043, §2.7.c: 0.55 Fy

 | $\ge 1.818$ | FHWA-NHI-00-043, §2.7.c: 0.55 Fy |
| 

Pullout of the reinforcement

MSE, Simplified Method, steel strips

FHWA-NHI-00-043, §2.7.c

 | $\ge 1.5$ | FHWA-NHI-00-043, §2.7.c |
| 

Sliding

MSE, FHWA's Simplified Method

FHWA-NHI-00-043, §2.7.c

 | $\ge 1.5$ | FHWA-NHI-00-043, §2.7.c |
| 

Bearing capacity

MSE, FHWA's Simplified Method

FHWA-NHI-00-043, §2.7.c

 | $\ge 2.5$ | FHWA-NHI-00-043, §2.7.c |
| 

Rupture of the reinforcement

MSE, Simplified Method, steel grids

FHWA-NHI-00-043, §2.7.c: 0.48 Fy

 | $\ge 2.083$ | FHWA-NHI-00-043, §2.7.c: 0.48 Fy |
| 

Reinforcement connection to the facing

MSE, Simplified Method, steel grids

FHWA-NHI-00-043, §2.7.c: 0.48 Fy

 | $\ge 2.083$ | FHWA-NHI-00-043, §2.7.c: 0.48 Fy |
| 

Pullout of the reinforcement

MSE, Simplified Method, steel grids

FHWA-NHI-00-043, §2.7.c

 | $\ge 1.5$ | FHWA-NHI-00-043, §2.7.c |
| 

Rupture of the reinforcement

MSE, Simplified Method, geosynthetics

FHWA-NHI-00-043, §2.7.c: Tal/1.5

 | $\ge 1.5$ | FHWA-NHI-00-043, §2.7.c: Tal/1.5 |
| 

Reinforcement connection to the facing

MSE, Simplified Method, geosynthetics

FHWA-NHI-00-043, §2.7.c: Tal/1.5

 | $\ge 1.5$ | FHWA-NHI-00-043, §2.7.c: Tal/1.5 |
| 

Pullout of the reinforcement

MSE, Simplified Method, geosynthetics

FHWA-NHI-00-043, §2.7.c

 | $\ge 1.5$ | FHWA-NHI-00-043, §2.7.c |
| 

Soil failure (reinforcement strain)

MSE, Stiffness Method

None beside it: the manuals' εmxmx limits a factored strain (FHWA-HIF-24-002, Eq. 106), and free mode's is unfactored

 |  | None beside it: the manuals' εmxmx limits a factored strain (FHWA-HIF-24-002, Eq. 106), and free mode's is unfactored |

The eccentricity comes with FHWA GEC 6’s $e \le B/6$ (§6.4.1); an MSE wall’s, with FHWA-NHI-00-043’s $e \le L/6$ on soil (§2.7.c).

### Under an earthquake

When the wall has an earthquake among its loads, it’s also checked under it, sliding, eccentricity and bearing, nothing in front counted ([Stability](https://rischio.io/docs/retaining-wall/theory/stability/#under-an-earthquake)), with beside each check the criteria of the manual whose combination free mode takes, where they compare with Rischio’s value: a gravity, cantilever or gabion wall’s from FHWA GEC 3 (§11.5.1), sliding 1.0 and the resultant within $B/4$ on soil, and nothing beside its bearing, which GEC 3 judges on the toe’s linear peak; an MSE wall’s from FHWA-HIF-24-002 (Step 8), sliding 1.0, and nothing beside its bearing and eccentricity, which that manual judges on factored loads. Inside an MSE wall, FHWA-NHI-00-043’s 75 % of the static ones (§2.7.c).

### A cantilever’s structure

A cantilever’s stem, toe and heel are checked with their bars under AASHTO LRFD alone, whose Section 5 gives the resistance factors and the limits: bending, least steel and shear, the rules of the bars’ spacing and cover, and under an earthquake bending and shear at $\phi$ = 1.0. In free mode, which designs no structure, Results gives their forces unfactored, with no verdict ([Structural design](https://rischio.io/docs/retaining-wall/theory/structural/)).

## Footings

| Check | Rule | Usual limit |
| --- | --- | --- |
| 
Bearing capacity

The ground under the footing giving way

$FS = \frac{q_n}{q_{max}}$

 | $FS = \frac{q_n}{q_{max}}$ | $\ge 3.0$ |
| 

Eccentricity along the width

The load inside the middle third, across the width

$e_B$

 | $e_B$ | $\le \frac{B}{6}$ |
| 

Eccentricity along the length

The load inside the middle third, along the length

$e_L$

 | $e_L$ | $\le \frac{L}{6}$ |
| 

Settlement

The footing's settlement: elastic, and the consolidation of a clay

$S$

 | $S$ | $\le 25\,\text{mm}$ |
| 

Bearing pressure

The pressure under the footing against your soil study's allowable one: the edge pressure, or under AASHTO the uniform one at the service limit state

$q_{max},\; \sigma_v$

 | $q_{max},\; \sigma_v$ | $\le q_a$ |

| Check | Reference | Source |
| --- | --- | --- |
| 
Bearing capacity

FHWA GEC-6 §5.2.6

 | $\ge 3.0$ | FHWA GEC-6 §5.2.6 |
| 

Sliding

FHWA GEC-6 §5.4

 | $\ge 1.5$ | FHWA GEC-6 §5.4 |
| 

Settlement

FHWA GEC-6 §8.3.1

 | $\le 0.025\,\mathrm{m}$ | FHWA GEC-6 §8.3.1 |

Each eccentricity comes with FHWA GEC 6’s $e \le B/6$ (§6.4.1), along each side.

## Piles

| Check | Rule | Usual limit |
| --- | --- | --- |
| 
Pile group

The group's axial capacity, as its piles or, with the toe in clay, as one block

$FS = \frac{Q_g}{Q}, \quad Q_g = \min(\eta, 1) \, n \, Q_u$

 | $FS = \frac{Q_g}{Q}, \quad Q_g = \min(\eta, 1) \, n \, Q_u$ | $\ge 3.0$ |
| 

Settlement of the group

The group's settlement on its equivalent footing, against what the structure tolerates

$s_g$

 | $s_g$ | $\le \delta_{tolerable}$ |
| 

Single pile

One pile's axial capacity against its load, when there's only one

$FS = \frac{Q_u}{Q}$

 | $FS = \frac{Q_u}{Q}$ | $\ge 3.0$ |
| 

The pile's section

A steel pile or a drilled shaft by AASHTO LRFD, after the geotechnics: compression, bending with axial load and shear, a shaft's cage against the code's rules

$\frac{P_r}{P_u},\; \frac{M_r}{M_u},\; \frac{V_r}{V_u}$

 | $\frac{P_r}{P_u},\; \frac{M_r}{M_u},\; \frac{V_r}{V_u}$ | $\ge 1.0$ |

| Check | Reference | Source |
| --- | --- | --- |
| 
Single pile

USACE EM 1110-2-2906, §4-2c: usual loading, a capacity not verified by a load test, 3.0

 | $\ge 3.0$ | USACE EM 1110-2-2906, §4-2c: usual loading, a capacity not verified by a load test, 3.0 |
| 

Pile group

USACE EM 1110-2-2906, §4-2c: usual loading, a capacity not verified by a load test, 3.0

 | $\ge 3.0$ | USACE EM 1110-2-2906, §4-2c: usual loading, a capacity not verified by a load test, 3.0 |
| 

Deflection at the head

FHWA GEC 9 (FHWA-HIF-18-031), App. E: the DOTs' most common limit

 | $\le 0.025\,\mathrm{m}$ | FHWA GEC 9 (FHWA-HIF-18-031), App. E: the DOTs' most common limit |
| 

Settlement of a shaft

The designer's: FHWA GEC 10 gives the range on bridges, p. 10-30

 |  | The designer's: FHWA GEC 10 gives the range on bridges, p. 10-30 |
| 

Settlement of the group

The designer's: FHWA GEC 12 §7.3.1 sets no number

 |  | The designer's: FHWA GEC 12 §7.3.1 sets no number |
| 

Single pile, Extreme Event I

Under an earthquake

USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3))

 | $\ge 1.7$ | USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3)) |
| 

Pile group, Extreme Event I

Under an earthquake

USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3))

 | $\ge 1.7$ | USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3)) |
| 

Uplift of a single pile, Extreme Event I

Under an earthquake

USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3))

 | $\ge 1.7$ | USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3)) |
| 

Uplift of the group, Extreme Event I

Under an earthquake

USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3))

 | $\ge 1.7$ | USACE EM 1110-2-2906, §4-2c: its extreme loading, read here as the earthquake's (the EM names none), a capacity not verified by a load test, 1.7; with it the EM asks a nonlinear analysis of the group showing a ductile, stable equilibrium (§4-2b(3)) |
| 

Single pile, Extreme Event II

After the scour check flood

USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25

 | $\ge 2.25$ | USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25 |
| 

Pile group, Extreme Event II

After the scour check flood

USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25

 | $\ge 2.25$ | USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25 |
| 

Uplift of a single pile, Extreme Event II

After the scour check flood

USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25

 | $\ge 2.25$ | USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25 |
| 

Uplift of the group, Extreme Event II

After the scour check flood

USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25

 | $\ge 2.25$ | USACE EM 1110-2-2906, §4-2c: unusual loading (an infrequent flood, §4-2b), a capacity not verified by a load test, 2.25 |
| 

Uplift of a single pile

UFS 3-220-20, Table 6-29 (USACE 1991)

 | $\ge 3.0$ | UFS 3-220-20, Table 6-29 (USACE 1991) |
| 

Uplift of the group

UFS 3-220-20, Table 6-29 (USACE 1991)

 | $\ge 3.0$ | UFS 3-220-20, Table 6-29 (USACE 1991) |

A drilled shaft’s settlement and a group’s take the tolerable settlement the designer gives: AASHTO leaves it to the structure (10.5.2.1), so no value sits beside them.

### A pile’s structure

A steel pile’s section and a drilled shaft’s with its cage are checked under AASHTO LRFD alone, whose Sections 5 and 6 give the resistance factors and the limits: compression, axial load with bending, and shear, each factored resistance at least the factored load, and a shaft’s cage against Section 5’s rules. In free mode, which designs no structure, Results gives the pile’s forces unfactored, with no structural check ([Structural resistance](https://rischio.io/docs/deep-foundation/theory/structural/)).

### Under an earthquake

When the load has an earthquake, the pile’s and the group’s axial checks, uplift included, run again under the earthquake (under AASHTO, its Extreme Event I), with the dead and live loads and the earthquake’s effects both ways. In free mode the loads are unfactored, and USACE EM 1110-2-2906’s factors of safety for a capacity not verified by a load test sit beside each check (§4-2c): 1.7 under the earthquake, read as the EM’s extreme loading (it names no earthquake, and with it asks a nonlinear analysis of the group showing a ductile, stable equilibrium, §4-2b), and 2.25 after the scour check flood, an unusual one. Free mode reads only the earthquake’s axial effects, so its lateral force and its moment at the heads show dimmed there. Under AASHTO the pile’s bending and its structural checks run under the earthquake too.

## Open channels

| Check | Rule | Usual limit |
| --- | --- | --- |
| 
Section capacity

The discharge fits below the lower bank

$Q$

 | $Q$ | $\le Q_{bank}$ |
| 

Freeboard

The water's depth below the lower bank, against the freeboard you ask for

$f = y_{bank} - y_n$

 | $f = y_{bank} - y_n$ | — |

The freeboard has a verdict once the designer gives the depth the water must leave below the lower bank; no manual’s value sits beside it.

---

Source: https://rischio.io/docs/reference/criteria/