# Inputs

Every field a model of a retaining wall takes, as the engine's schema gives it: what it is, its unit and convention, and its limits.

A model is a JSON document, the same one the studio’s forms build, its AI writes and an agent sends with `create_model`. Every element has an `id`, stable and unique in the model (the results name by it the elements each check depends on), and a `name`, shown on the canvas and in the report; strata can also carry a `color`. Every model states its `contract_version`, today 15. Units are SI: kN, m, kPa, kN/m³ and degrees.

These are its fields, from the engine’s own schema: what the studio’s forms are built from, and what `get_tool_schema` gives an agent.

`wall` one of · required

`cantilever` A reinforced concrete cantilever wall, a stem on a footing whose heel carries the backfill (AASHTO LRFD 10th, 11.6, Fig. C11.6.1.1-1; L or T): over a short heel, Coulomb on the vertical through the heel.

`kind` text · required · = "cantilever"

A cantilever wall (AASHTO LRFD 10th, 11.6, Fig. C11.6.1.1-1, the reinforced concrete cantilever and counterfort walls; L or T): a stem on a footing whose heel carries the backfill. Over a short heel (the Rankine wedge from the heel meets the stem) the thrust acts by Coulomb on the vertical through the heel, at δ′, with the soil left of it as wall weight (C3.11.5.3, Fig. C3.11.5.3-1b, right). Choose it for a stem on a footing.

`parts` list · required · 1–20 items

Bottom up, in a section with the toe at x = 0 and the backfill towards larger x. The wall's height is the sum of the parts' heights. In a gravity or cantilever wall, each part's base lies within the top of the part below it (a stem on its footing). Gabion levels may step or overhang freely, but the centre of gravity of each level, with the levels on it, lies over where it bears on the level below.

Each item is one of:

`rectangle`

`shape` text · required · = "rectangle"

`x` number · optional · default 0

Horizontal position of the part's bottom-left corner, from the toe (m).

`height` number · required · > 0

Height (m).

`width` number · required · > 0

Width (m).

`trapezoid`

`shape` text · required · = "trapezoid"

`x` number · optional · default 0

Horizontal position of the part's bottom-left corner, from the toe (m).

`height` number · required · > 0

Height (m).

`bottom_width` number · required · > 0

Width at the bottom (m).

`top_width` number · required · ≥ 0

Width at the top (m); 0 makes a triangle.

`back_batter` number · optional · ≥ 0 · < 90 · default 0

Angle from the vertical of the face on the backfill side (deg); 0 keeps that face vertical and the other one leans.

`embedment_depth` number · optional · ≥ 0 · default 0

Depth of the base below the ground in front of the toe (m), for the bearing and the sliding stratum. The passive resistance in front is neglected, as AASHTO allows (11.6.3.5) and FHWA's examples do.

`embedment_permanent` yes or no · optional · default false

Whether the soil in front of the toe, over the base, stays through the wall's life: no scour, excavation or trench will take it away. AASHTO counts that soil's shear in the base's bearing (dq, Eq. 10.6.3.1.2a-10, at most 1.4; 11.6.3.2 sends the base to 10.6.3) only where it stays and no stratum above the base is weaker than the one below it (10.6.3.1.2a); false, the default, takes dq = 1.0, as for a wall whose toe may be dug out or scoured.

`allowable_bearing_pressure` number · optional · > 0

Optional: the allowable bearing pressure a soil study gives for the wall's base at its depth, or a presumptive value (AASHTO Table C10.6.2.5.1-1) (kPa): the total pressure at the base, every load that reaches it, is checked against it (where the study gives a net value, add the overburden pressure at the base). In free mode the edge pressure, the greatest of the base's linear pressure diagram (an MSE block's uniform pressure); under AASHTO the uniform pressure on the effective area at Service I, the service limit state only (10.5.2.1; a wall's base by 11.6.2.2), the strength limit state's bearing still from the strata. Empty, no such check.

`methods` group · optional

Methods (advanced): each by the data unless the designer chooses one.

`earth_pressure` text · optional · one of: by\_data, rankine, coulomb, rankine\_cohesion · default "by\_data"

The pressure of the backfill, p = K γ z without a cohesion term, as AASHTO takes it (3.11.5.1, C3.11.5.3): a backfill's c' isn't counted, but by rankine\_cohesion. by\_data: as AASHTO (C3.11.5.3) and FHWA take it, Rankine on the virtual back (the vertical through the heel) over a long heel; Coulomb with the wall friction δ' elsewhere: on the wall's back where no soil rests on the wall inside the plane from the heel to the crest, and over a short heel by the wall's kind, a cantilever's on the vertical through the heel (C3.11.5.3, Fig. C3.11.5.3-1b, right), a gravity wall's and gabions' on that plane, the wall's own back (the figure's left; 3.11.5.9); Rankine for an undrained backfill; the answer's methods say which and why. Or chosen: rankine, Rankine's active pressure on the virtual back; or coulomb, Coulomb's where by\_data puts it (a drained backfill), Rankine's plane over a long heel; or, in free mode only and on a level backfill, rankine\_cohesion, Rankine's active pressure on the virtual back with each drained stratum's c', Bell's equation σ'a = σ'v Ka − 2c'√Ka (an undrained stratum pushes as by rankine, K = 1 without its su), none above the tension crack, which holds no water, and where a stratum's c' passes 5 kPa never under 5z kPa, z the depth in m (FHWA NHI-06-089, p. 10-15): for a designer who counts a clayey backfill's c'; AASHTO doesn't admit it (3.11.5.3, C3.11.1), and the data never take it. Under an earthquake Mononobe and Okabe's PAE takes φ' alone, the cohesion left out. Behind a broken back no closed form holds: each back takes AASHTO's trial wedge (3.11.5.3), Coulomb's at the wall's δ', Rankine's along the ground's chord.

`wall_friction` number · optional · ≥ 0 · ≤ 1 · default 0.5

Wall friction δ'/φ', for Coulomb's: Das & Sivakugan design with ½ to ⅔ (½ is the safe side); UFC 3-220-20 gives tan δ = 0.9 tan φ' at the back of a gabion wall.

`material` group · required

A cantilever's reinforced concrete: its weight, and its f′c for the stem's and the footing's structural design, a code's (codes.BY\_MODE).

`unit_weight` number · required · > 0

Unit weight (kN/m³): about 24 for concrete.

`concrete_strength` number · optional · > 0 · default 27579.0291727

Compressive strength f′c of the wall's concrete (kPa): 27,579 unless given. Under a design code, with the bars, the stem's and the footing's structural resistance (AASHTO Section 5); refused in free mode, where nothing reads it.

`bars` group · optional

Optional, under a design code: the bars of the stem's back, the footing's bottom under the toe and its top over the heel, for their structural design by AASHTO LRFD 10th, Section 5 (11.6.4); POST /retaining-wall/reinforcement proposes the lightest that pass. Without them, the answer gives the stem's and the footing's design forces, and their moment and shear along each part. Refused in free mode, which has no load or resistance factors to design reinforced concrete by.

`stem` group · optional

Optional: the stem's back face over its base, for the stem's checks.

`bar_diameter` number · required · > 0

Diameter of the bars in the stem's back face (m): a bar of ASTM A615 or A706, #3 to #11, by its nominal diameter.

`bar_spacing` number · required · > 0

Centre-to-centre spacing of the bars in the stem's back face, along the wall (m).

`cover` number · optional · > 0 · default 0.0508

Clear cover to the bars (m): 0.0508 by default, AASHTO's least on an exterior face (Table 5.10.1-1).

`toe` group · optional

Optional: the footing's bottom under the toe, for the toe's checks.

`bar_diameter` number · required · > 0

Diameter of the bars in the footing's bottom (m): a bar of ASTM A615 or A706, #3 to #11, by its nominal diameter.

`bar_spacing` number · required · > 0

Centre-to-centre spacing of the bars in the footing's bottom, along the wall (m).

`cover` number · optional · > 0 · default 0.0762

Clear cover to the bars (m): 0.0762 by default, AASHTO's least cast against the ground (Table 5.10.1-1).

`heel` group · optional

Optional: the footing's top over the heel, for the heel's checks.

`bar_diameter` number · required · > 0

Diameter of the bars in the footing's top (m): a bar of ASTM A615 or A706, #3 to #11, by its nominal diameter.

`bar_spacing` number · required · > 0

Centre-to-centre spacing of the bars in the footing's top, along the wall (m).

`cover` number · optional · > 0 · default 0.0508

Clear cover to the bars (m): 0.0508 by default, AASHTO's least on an exterior face (Table 5.10.1-1).

`yield_strength` number · optional · > 0 · default 413685.43759

Yield strength fy of the bars (kPa): 413,685 by default, Grade 60 (AASHTO 5.4.3.1). It says their grade, which sets γ3 with their standard: at most 551,581, Grade 80, the highest AASHTO gives a γ3 for (5.6.3.3).

`bar_standard` text · optional · one of: a615, a706 · default "a615"

The bars' standard: ASTM A615, or A706 (low-alloy, weldable). With the grade their fy says, it sets γ3 in the least flexural resistance: 0.67 or 0.75 at Grade 60 (AASHTO 5.6.3.3).

`exposure_class` text · optional · one of: class\_1, class\_2 · default "class\_1"

The exposure crack control holds the bars' spacing to (AASHTO 5.6.7): Class 1, γe 1.00, the usual one; Class 2, γe 0.75, where a crack's width matters more, as on a face that water or deicing salts reach.

`gabion` Stacked gabion levels, one part each: every level is checked too.

`kind` text · required · = "gabion"

A gabion wall, a prefabricated modular wall (AASHTO LRFD 10th, 11.11): stacked baskets of rock, each level checked; the thrust on the plane from the bottom level's heel to the top level's back corner (3.11.5.9, Fig. 3.11.5.9-2).

`parts` list · required · 1–20 items

Bottom up, in a section with the toe at x = 0 and the backfill towards larger x. The wall's height is the sum of the parts' heights. In a gravity or cantilever wall, each part's base lies within the top of the part below it (a stem on its footing). Gabion levels may step or overhang freely, but the centre of gravity of each level, with the levels on it, lies over where it bears on the level below.

Each item is one of:

`rectangle`

`shape` text · required · = "rectangle"

`x` number · optional · default 0

Horizontal position of the part's bottom-left corner, from the toe (m).

`height` number · required · > 0

Height (m).

`width` number · required · > 0

Width (m).

`trapezoid`

`shape` text · required · = "trapezoid"

`x` number · optional · default 0

Horizontal position of the part's bottom-left corner, from the toe (m).

`height` number · required · > 0

Height (m).

`bottom_width` number · required · > 0

Width at the bottom (m).

`top_width` number · required · ≥ 0

Width at the top (m); 0 makes a triangle.

`back_batter` number · optional · ≥ 0 · < 90 · default 0

Angle from the vertical of the face on the backfill side (deg); 0 keeps that face vertical and the other one leans.

`embedment_depth` number · optional · ≥ 0 · default 0

Depth of the base below the ground in front of the toe (m), for the bearing and the sliding stratum. The passive resistance in front is neglected, as AASHTO allows (11.6.3.5) and FHWA's examples do.

`embedment_permanent` yes or no · optional · default false

Whether the soil in front of the toe, over the base, stays through the wall's life: no scour, excavation or trench will take it away. AASHTO counts that soil's shear in the base's bearing (dq, Eq. 10.6.3.1.2a-10, at most 1.4; 11.6.3.2 sends the base to 10.6.3) only where it stays and no stratum above the base is weaker than the one below it (10.6.3.1.2a); false, the default, takes dq = 1.0, as for a wall whose toe may be dug out or scoured.

`allowable_bearing_pressure` number · optional · > 0

Optional: the allowable bearing pressure a soil study gives for the wall's base at its depth, or a presumptive value (AASHTO Table C10.6.2.5.1-1) (kPa): the total pressure at the base, every load that reaches it, is checked against it (where the study gives a net value, add the overburden pressure at the base). In free mode the edge pressure, the greatest of the base's linear pressure diagram (an MSE block's uniform pressure); under AASHTO the uniform pressure on the effective area at Service I, the service limit state only (10.5.2.1; a wall's base by 11.6.2.2), the strength limit state's bearing still from the strata. Empty, no such check.

`methods` group · optional

Methods (advanced): each by the data unless the designer chooses one.

`earth_pressure` text · optional · one of: by\_data, rankine, coulomb, rankine\_cohesion · default "by\_data"

The pressure of the backfill, p = K γ z without a cohesion term, as AASHTO takes it (3.11.5.1, C3.11.5.3): a backfill's c' isn't counted, but by rankine\_cohesion. by\_data: as AASHTO (C3.11.5.3) and FHWA take it, Rankine on the virtual back (the vertical through the heel) over a long heel; Coulomb with the wall friction δ' elsewhere: on the wall's back where no soil rests on the wall inside the plane from the heel to the crest, and over a short heel by the wall's kind, a cantilever's on the vertical through the heel (C3.11.5.3, Fig. C3.11.5.3-1b, right), a gravity wall's and gabions' on that plane, the wall's own back (the figure's left; 3.11.5.9); Rankine for an undrained backfill; the answer's methods say which and why. Or chosen: rankine, Rankine's active pressure on the virtual back; or coulomb, Coulomb's where by\_data puts it (a drained backfill), Rankine's plane over a long heel; or, in free mode only and on a level backfill, rankine\_cohesion, Rankine's active pressure on the virtual back with each drained stratum's c', Bell's equation σ'a = σ'v Ka − 2c'√Ka (an undrained stratum pushes as by rankine, K = 1 without its su), none above the tension crack, which holds no water, and where a stratum's c' passes 5 kPa never under 5z kPa, z the depth in m (FHWA NHI-06-089, p. 10-15): for a designer who counts a clayey backfill's c'; AASHTO doesn't admit it (3.11.5.3, C3.11.1), and the data never take it. Under an earthquake Mononobe and Okabe's PAE takes φ' alone, the cohesion left out. Behind a broken back no closed form holds: each back takes AASHTO's trial wedge (3.11.5.3), Coulomb's at the wall's δ', Rankine's along the ground's chord.

`wall_friction` number · optional · ≥ 0 · ≤ 1 · default 0.5

Wall friction δ'/φ', for Coulomb's: Das & Sivakugan design with ½ to ⅔ (½ is the safe side); UFC 3-220-20 gives tan δ = 0.9 tan φ' at the back of a gabion wall.

`material` group · required

`unit_weight` number · required · > 0

Unit weight of the gabions, voids included (kN/m³): the rock's times (1 − n), γg = γp (1 − n) (Maccaferri, Eq. 145); a rock of 26 kN/m³ at n = 0.40 gives 15.6.

`porosity` number · optional · > 0 · < 1 · default 0.4

Porosity n of the rock fill, the share of voids: water fills them below the water table, so a gabion weighs γ + n γw there. 0.40 by default, the design maximum of IRC:SP:116-2018 and the usual value in Gawac; 0.30 to 0.40 (Maccaferri, Obras de Contenção, p. 183).

`level_friction_angle` number · required · > 0 · < 90

Friction between stacked gabion levels, for each level's sliding (deg).

`gravity` A rigid gravity wall of mass concrete or masonry, or a semigravity one that holds the backfill by its own weight (AASHTO LRFD 10th, 11.6, Fig. C11.6.1.1-1): over a short heel, Coulomb on the wall's own back.

`kind` text · required · = "gravity"

A gravity wall (AASHTO LRFD 10th, 11.6, Fig. C11.6.1.1-1, the rigid gravity walls): mass concrete or masonry that holds the backfill by its own weight, its back the face the backfill pushes. Over a short heel (the Rankine wedge from the heel meets the wall) the thrust acts by Coulomb on the wall's own back, the plane from the heel to the crest's back corner, at δ′, with the soil inside it as wall weight (Fig. C3.11.5.3-1b, left). Choose it for a gravity or semigravity wall without a reinforced stem on a footing.

`parts` list · required · 1–20 items

Bottom up, in a section with the toe at x = 0 and the backfill towards larger x. The wall's height is the sum of the parts' heights. In a gravity or cantilever wall, each part's base lies within the top of the part below it (a stem on its footing). Gabion levels may step or overhang freely, but the centre of gravity of each level, with the levels on it, lies over where it bears on the level below.

Each item is one of:

`rectangle`

`shape` text · required · = "rectangle"

`x` number · optional · default 0

Horizontal position of the part's bottom-left corner, from the toe (m).

`height` number · required · > 0

Height (m).

`width` number · required · > 0

Width (m).

`trapezoid`

`shape` text · required · = "trapezoid"

`x` number · optional · default 0

Horizontal position of the part's bottom-left corner, from the toe (m).

`height` number · required · > 0

Height (m).

`bottom_width` number · required · > 0

Width at the bottom (m).

`top_width` number · required · ≥ 0

Width at the top (m); 0 makes a triangle.

`back_batter` number · optional · ≥ 0 · < 90 · default 0

Angle from the vertical of the face on the backfill side (deg); 0 keeps that face vertical and the other one leans.

`embedment_depth` number · optional · ≥ 0 · default 0

Depth of the base below the ground in front of the toe (m), for the bearing and the sliding stratum. The passive resistance in front is neglected, as AASHTO allows (11.6.3.5) and FHWA's examples do.

`embedment_permanent` yes or no · optional · default false

Whether the soil in front of the toe, over the base, stays through the wall's life: no scour, excavation or trench will take it away. AASHTO counts that soil's shear in the base's bearing (dq, Eq. 10.6.3.1.2a-10, at most 1.4; 11.6.3.2 sends the base to 10.6.3) only where it stays and no stratum above the base is weaker than the one below it (10.6.3.1.2a); false, the default, takes dq = 1.0, as for a wall whose toe may be dug out or scoured.

`allowable_bearing_pressure` number · optional · > 0

Optional: the allowable bearing pressure a soil study gives for the wall's base at its depth, or a presumptive value (AASHTO Table C10.6.2.5.1-1) (kPa): the total pressure at the base, every load that reaches it, is checked against it (where the study gives a net value, add the overburden pressure at the base). In free mode the edge pressure, the greatest of the base's linear pressure diagram (an MSE block's uniform pressure); under AASHTO the uniform pressure on the effective area at Service I, the service limit state only (10.5.2.1; a wall's base by 11.6.2.2), the strength limit state's bearing still from the strata. Empty, no such check.

`methods` group · optional

Methods (advanced): each by the data unless the designer chooses one.

`earth_pressure` text · optional · one of: by\_data, rankine, coulomb, rankine\_cohesion · default "by\_data"

The pressure of the backfill, p = K γ z without a cohesion term, as AASHTO takes it (3.11.5.1, C3.11.5.3): a backfill's c' isn't counted, but by rankine\_cohesion. by\_data: as AASHTO (C3.11.5.3) and FHWA take it, Rankine on the virtual back (the vertical through the heel) over a long heel; Coulomb with the wall friction δ' elsewhere: on the wall's back where no soil rests on the wall inside the plane from the heel to the crest, and over a short heel by the wall's kind, a cantilever's on the vertical through the heel (C3.11.5.3, Fig. C3.11.5.3-1b, right), a gravity wall's and gabions' on that plane, the wall's own back (the figure's left; 3.11.5.9); Rankine for an undrained backfill; the answer's methods say which and why. Or chosen: rankine, Rankine's active pressure on the virtual back; or coulomb, Coulomb's where by\_data puts it (a drained backfill), Rankine's plane over a long heel; or, in free mode only and on a level backfill, rankine\_cohesion, Rankine's active pressure on the virtual back with each drained stratum's c', Bell's equation σ'a = σ'v Ka − 2c'√Ka (an undrained stratum pushes as by rankine, K = 1 without its su), none above the tension crack, which holds no water, and where a stratum's c' passes 5 kPa never under 5z kPa, z the depth in m (FHWA NHI-06-089, p. 10-15): for a designer who counts a clayey backfill's c'; AASHTO doesn't admit it (3.11.5.3, C3.11.1), and the data never take it. Under an earthquake Mononobe and Okabe's PAE takes φ' alone, the cohesion left out. Behind a broken back no closed form holds: each back takes AASHTO's trial wedge (3.11.5.3), Coulomb's at the wall's δ', Rankine's along the ground's chord.

`wall_friction` number · optional · ≥ 0 · ≤ 1 · default 0.5

Wall friction δ'/φ', for Coulomb's: Das & Sivakugan design with ½ to ⅔ (½ is the safe side); UFC 3-220-20 gives tan δ = 0.9 tan φ' at the back of a gabion wall.

`material` group · required

Mass or reinforced concrete, or mortared masonry: no voids.

`unit_weight` number · required · > 0

Unit weight (kN/m³): about 24 for concrete.

`mse` A mechanically stabilized earth wall: layers of reinforcement in a granular fill, one length, at one vertical spacing.

`kind` text · required · = "mse"

A mechanically stabilized earth wall (AASHTO LRFD 10th, 11.10): layers of reinforcement in a granular fill behind a facing.

`height` number · required · > 0 · ≤ 100

Height H of the wall, from its base to its top (m).

`embedment_depth` number · optional · ≥ 0 · default 0

Depth of the base below the ground in front of the face (m).

`allowable_bearing_pressure` number · optional · > 0

Optional: the allowable bearing pressure a soil study gives for the wall's base at its depth, or a presumptive value (AASHTO Table C10.6.2.5.1-1) (kPa): the total pressure at the base, every load that reaches it, is checked against it (where the study gives a net value, add the overburden pressure at the base). In free mode the edge pressure, the greatest of the base's linear pressure diagram (an MSE block's uniform pressure); under AASHTO the uniform pressure on the effective area at Service I, the service limit state only (10.5.2.1; a wall's base by 11.6.2.2), the strength limit state's bearing still from the strata. Empty, no such check.

`reinforced_fill` group · required

The granular fill the reinforcement is laid in.

`unit_weight` number · required · > 0

Unit weight γ\_r of the reinforced fill (kN/m³).

`friction_angle` number · required · > 0 · ≤ 40

Friction angle φ'\_r of the reinforced fill (deg), granular: FHWA GEC 11 takes 34° unless the fill is tested, and never above 40°.

`uniformity_coefficient` number · optional · ≥ 1

Optional: C\_u = D60/D10 of the fill, for ribbed strips' pullout, F\* = 1.2 + log C\_u at the top, at most 2.0; 4 unless known (FHWA GEC 11, Eq. 3-4).

`reinforcement` one of · required

`geogrid` Geogrid strips across the layer, at a coverage ratio: extensible.

`reinforcement_type` text · required · = "geogrid"

`tensile_strength` number · required · > 0

Ultimate tensile strength T\_ult of the geogrid (kN/m).

`installation_damage` number · required · ≥ 1

Reduction factor for installation damage RF\_ID, from the product's tests in the fill: 1.1 to 1.85 for a geogrid (FHWA HIF-24-002, Table 12).

`creep_reduction` number · required · ≥ 1

Reduction factor for creep RF\_CR, from the product's creep tests: 1.5 to 2.5 for polyester, 4 to 5 for polypropylene, 2.6 to 5 for HDPE (FHWA HIF-24-002, Table 13).

`durability_reduction` number · required · ≥ 1

Reduction factor for chemical and biological degradation RF\_D: 1.1 to 2.0 (FHWA HIF-24-002, 3.5.2.4).

`interaction_coefficient` number · optional · > 0 · ≤ 1.2 · default 0.666666666667

C\_i, the pullout resistance over tan φ'\_r, F\* = C\_i tan φ'\_r: 2/3 unless tested (FHWA GEC 11); Das gives 0.55 to 0.8 by the fill.

`coverage_ratio` number · optional · > 0 · ≤ 1 · default 1

R\_c, the share of the layer the geogrid covers: 1.2 m wide pieces 0.3 m apart are 0.8.

`secant_stiffness` number · optional · > 0

Optional: J, the secant tensile stiffness of the geogrid per metre of its width at 2 % strain and 1,000 hours, from its creep tests (AASHTO R 69), kN/m. The Stiffness Method (AASHTO LRFD 10th, 11.10.6.2.1e, its method for geosynthetics) takes it, and a geosynthetic without it is taken by the Simplified Method (Appendix B11).

`geotextile` A geotextile sheet over the whole layer: extensible.

`reinforcement_type` text · required · = "geotextile"

`tensile_strength` number · required · > 0

Ultimate tensile strength T\_ult of the geotextile (kN/m).

`installation_damage` number · required · ≥ 1

Reduction factor for installation damage RF\_ID, from the product's tests in the fill: 1.1 to 2.5 for a geotextile (FHWA HIF-24-002, Table 12).

`creep_reduction` number · required · ≥ 1

Reduction factor for creep RF\_CR, from the product's creep tests: 1.5 to 2.5 for polyester, 4 to 5 for polypropylene, 2.6 to 5 for HDPE (FHWA HIF-24-002, Table 13).

`durability_reduction` number · required · ≥ 1

Reduction factor for chemical and biological degradation RF\_D: 1.1 to 2.0 (FHWA HIF-24-002, 3.5.2.4).

`interaction_coefficient` number · optional · > 0 · ≤ 1.2 · default 0.666666666667

C\_i, the pullout resistance over tan φ'\_r, F\* = C\_i tan φ'\_r: 2/3 unless tested (FHWA GEC 11, Eq. 3-8).

`secant_stiffness` number · optional · > 0

Optional: J, the secant tensile stiffness of the geotextile per metre of its width at 2 % strain and 1,000 hours, from its creep tests (AASHTO R 69), kN/m. The Stiffness Method (AASHTO LRFD 10th, 11.10.6.2.1e, its method for geosynthetics) takes it, and a geosynthetic without it is taken by the Simplified Method (Appendix B11).

`metallic_strip` Galvanized steel strips, ribbed, at a horizontal spacing in each layer: inextensible.

`reinforcement_type` text · required · = "metallic\_strip"

`reinforcement_width` number · required · > 0

Width b of a strip (m): 50 to 100 mm.

`reinforcement_thickness` number · required · > 0

Thickness of a strip as built, before corrosion (m): 4 to 6 mm.

`horizontal_spacing` number · required · > 0

Horizontal spacing S\_H of the strips in a layer, centre to centre (m): a panel's width over its strips.

`yield_strength` number · required · > 0

Yield strength F\_y of the steel (kPa): 413 700 for Grade 60.

`design_life` number · optional · > 0 · default 75

Design life (years), for the corrosion: 75 (AASHTO). The strip loses AASHTO's sacrificial thickness over it (11.10.6.4.2a): its zinc, 0.0864 mm, at 0.0147 mm a year for 2 years and 0.00406 mm a year after, then the steel at 0.0119 mm a year on each side.

`steel_grid` Steel grids, bar mats or welded wire mats, galvanized, at a horizontal spacing in each layer: inextensible (AASHTO LRFD 10th, 11.10.6.4.1, Fig. 11.10.6.4.1-1). A continuous mesh is a grid as wide as its spacing.

`reinforcement_type` text · required · = "steel\_grid"

`reinforcement_width` number · required · > 0

Width b of a grid (m), across its longitudinal bars; for a mesh continuous along the wall, its horizontal spacing.

`bar_count` integer · required · ≥ 1

Number of longitudinal bars (wires) in a grid, those that carry the load.

`bar_diameter` number · required · > 0

Diameter of the longitudinal bars as built, before corrosion (m): a W11 wire is 9.5 mm. The corrosion is taken off its radius (AASHTO 11.10.6.4.2a).

`transverse_bar_diameter` number · required · > 0

Diameter t of the transverse bars (m), no more than the longitudinal ones' (11.10.6.4.2a): with their spacing, the grid's pullout F\* = 20 t/S\_t at the top to 10 t/S\_t at 6.096 m (AASHTO Fig. 11.10.6.3.2-2).

`transverse_bar_spacing` number · required · > 0

Spacing S\_t of the transverse bars along the grid (m), uniform over its length (11.10.6.3.2): 0.15 to 0.6.

`horizontal_spacing` number · required · > 0

Horizontal spacing S\_H of the grids in a layer, centre to centre (m): a panel's width over its grids; the grid's width for a continuous mesh.

`yield_strength` number · required · > 0

Yield strength F\_y of the steel (kPa): 448,159 for a grid's usual wire.

`design_life` number · optional · > 0 · default 75

Design life (years), for the corrosion: 75 (AASHTO).

`vertical_spacing` number · required · ≥ 0.1

Vertical spacing S\_V of the layers (m): 0.3 to 0.8.

`first_layer_depth` number · optional · > 0

Optional: the depth of the top layer below the top of the wall (m); S\_V/2 by default.

`reinforcement_length` number · required · > 0

Length L of the reinforcement, every layer the same (m): at least 0.7 H and 2.4 m, which the minimum\_resistant\_length check judges (FHWA GEC 11).

`facing` text · optional · one of: rigid, flexible · default "rigid"

The facing: rigid (precast concrete panels, modular blocks) or flexible (welded wire, a facing mat continuous with the reinforcement). A steel grid connected to a rigid facing takes AASHTO's lower tension factor, φ 0.65 against the strips' 0.75 (Table 11.5.7-1, note 5); rigid by default, the safe side.

`connection` one of · optional

Optional: the reinforcement's connection to the facing, steel or geosynthetic, with its strength (AASHTO LRFD 10th, 11.10.6.4.4): its load To = Tmax at every layer (11.10.6.2.2) is checked against it, static and under an earthquake (11.10.7.3). Empty, the connection isn't checked.

`geosynthetic` A geosynthetic joined to the facing: between blocks, behind them or cast into a panel.

`connection_type` text · required · = "geosynthetic"

`long_term_reduction` number · required · > 0 · ≤ 1

CRcr, the long-term connection strength reduction factor, from the connection tests at the wall's confining pressures between the facing units: Tultconn/(RFCR Tlot) from short-term tests, or Tcrc/Tlot from connection creep tests (AASHTO LRFD 10th, Eqs. 11.10.6.4.4b-2 and -3). Tac = Tult CRcr / RFD (Eq. 11.10.6.4.4b-1).

`short_term_reduction` number · optional · > 0 · ≤ 1

CRu, the short-term connection strength reduction factor, Tultconn/Tlot, from the short-term connection tests: the earthquake's dynamic load takes it, the creep not reducing it (AASHTO LRFD 10th, Eq. 11.10.7.3-2). Required under an earthquake.

`frictional` yes or no · optional · default true

The connection holds partly or wholly by friction between the facing blocks and the geosynthetic: under an earthquake its strength is 80 % of its static value (AASHTO LRFD 10th, 11.10.7.3). True by default, the safe side; false for a mechanical connection that doesn't rely on friction.

`steel` Steel strips or grids joined to the facing by a steel connector.

`connection_type` text · required · = "steel"

`connector_strength` number · required · > 0

Nominal tensile strength of each strip's or grid's connection to the facing (kN per connection), its long-term value after the face's corrosion (AASHTO LRFD 10th, 11.10.6.4.4a): the connector's, from its tests (5.10.8.3) or its steel (6.13.3). Over the reinforcement's horizontal spacing it is Tac Rc per metre of wall.

`methods` group · optional

Methods (advanced): each by the data unless the designer chooses one.

`reinforcement_load` text · optional · one of: by\_data, coherent\_gravity, stiffness, simplified · default "by\_data"

How the load in each layer, T\_max, is found (AASHTO LRFD 10th, 11.10.6.2.1). by\_data: AASHTO's method for the reinforcement, the Coherent Gravity Method for steel strips (11.10.6.2.1d: k0 to ka over 6.096 m, Meyerhof's σv under the mass above each layer) and the Stiffness Method for a geotextile or a geogrid with its secant stiffness J (11.10.6.2.1e, with its soil-failure strain checked at the service limit state, 11.10.4.3); a geosynthetic without J, the Simplified Method, with a warning; the answer's methods say which and why. Or chosen: the Simplified Method of Appendix B11, which AASHTO keeps as also acceptable for both steel and geosynthetics (kr/ka by the reinforcement, σv = γr Z + q), for the designer who designs every wall by one method; it has its own resistance factors (B11.2). Each method is for its reinforcement: the Coherent Gravity Method only for steel, the Stiffness Method only for geosynthetics.

`backfill` group · required

`surface` one of · optional

The backfill's surface from the wall's crest: a plane, level by default or sloping, or a broken back, a slope that levels off. Strips and lines on the surface need it level.

`broken` A broken back: the surface rises from the wall's crest at its slope and levels off \`height\` above it (AASHTO LRFD 10th, Fig. C3.11.5.8.1-1). Its thrust comes from AASHTO's trial wedge (3.11.5.3), static and under an earthquake (C11.6.5.3), on a backfill of one soil.

`shape` text · required · = "broken"

The surface's shape: a slope from the crest that levels off.

`slope_angle` number · required · > 0 · < 90

Slope of the backfill surface from the crest (deg from the horizontal), rising away from the wall, no steeper than the backfill's friction angle.

`height` number · required · > 0

Height of the slope above the wall's crest (m): from there on the surface is level.

`plane` The backfill's surface a plane from the wall's crest, level or sloping: Rankine's and Coulomb's own (AASHTO LRFD 10th, Fig. 3.11.5.3-1).

`shape` text · optional · = "plane" · default "plane"

The surface's shape: a plane from the crest on.

`slope_angle` number · optional · ≥ 0 · < 90 · default 0

Slope of the backfill surface (deg from the horizontal), rising away from the wall; 0, level. No steeper than the friction angle of any backfill stratum.

`strata` list · required · 1–50 items

Top down from the crest to the base, each with its thickness; the last one may leave it out, and it reaches the base (given, they add up to the wall's height).

Each item is one of:

`drained` A granular soil, or a clay in the long term: its effective strength.

`thickness` number · optional · > 0 · ≤ 1000

Thickness (m), at most 1000 (app.application.bounds).

`unit_weight` number · required · > 0

Unit weight γ (kN/m³). Without a measurement, AASHTO's traditional values (Table 3.5.1-1): a compacted sand, silt or clay 18.9; a loose sand, silt or gravel 15.7; a soft clay 15.7; a rolled gravel 22.0.

`saturated_unit_weight` number · optional · > 0

Saturated unit weight γsat (kN/m³), at least γ and at most γ + 9.81, and more than water's 9.81. Required where the stratum reaches below the water table.

`soil_type` text · required · one of: gravel, sand, silty\_sand, clayey\_sand, silt, clay, rockfill

What the soil is: gravel, sand (clean, fine to coarse, or slightly silty), silty sand, clayey sand, silt or clay; or a quarried rock fill. Each method reads it to know whether it's for this soil (a sand's methods, a clay's), and nothing is assumed without it. A drained stratum may be any type (a clay in the long term, by c' and φ'); an undrained one is a clay or a silt.

`behavior` text · required · = "drained"

`cohesion` number · optional · ≥ 0 · default 0

Cohesion c' (kPa).

`friction_angle` number · required · > 0 · < 90

Friction angle φ' (deg).

`undrained` A clay in the short term: its undrained strength, φ = 0.

`thickness` number · optional · > 0 · ≤ 1000

Thickness (m), at most 1000 (app.application.bounds).

`unit_weight` number · required · > 0

Unit weight γ (kN/m³). Without a measurement, AASHTO's traditional values (Table 3.5.1-1): a compacted sand, silt or clay 18.9; a loose sand, silt or gravel 15.7; a soft clay 15.7; a rolled gravel 22.0.

`saturated_unit_weight` number · optional · > 0

Saturated unit weight γsat (kN/m³), at least γ and at most γ + 9.81, and more than water's 9.81. Required where the stratum reaches below the water table.

`soil_type` text · required · one of: clay, silt

What the soil is: a clay or a silt, the soils taken undrained in the short term (a granular soil is always drained, Das & Sivakugan, section 2.22: make the stratum drained).

`behavior` text · required · = "undrained"

`undrained_shear_strength` number · required · > 0

Undrained shear strength cu (kPa).

`water_table` group · optional

null when the backfill is drained, the usual case.

`depth` number · required · ≥ 0

Depth below the wall's crest (m): behind the wall the water can't stand above it.

`foundation` group · required

The ground under and in front of the wall: the footing's strata (AASHTO 11.6.2.2 and 11.6.3.2 send a wall's base to a footing's methods, 10.6).

`strata` list · required · 1–50 items

Top down from the ground in front of the toe; the last stratum may leave its thickness out (it extends down); given, the profile ends at its bottom, over a rigid layer the settlement stops at. A rock ends the profile, below the base's soil: the rigid base the settlement stops at, which the bearing doesn't count (the conservative side). A base resting on rock isn't computed.

Each item is one of:

`drained` A sand, or a clay in the long term: its effective strength, asked where a method of the model reads it (strength\_asked); a sand's relative density, its state, which only the mode of a base's bearing failure reads (docs/ground-model.md, rule 3).

`thickness` number · optional · > 0 · ≤ 1000

Thickness (m), at most 1000 (app.application.bounds).

`unit_weight` number · required · > 0

Unit weight γ (kN/m³). Without a measurement, AASHTO's traditional values (Table 3.5.1-1): a compacted sand, silt or clay 18.9; a loose sand, silt or gravel 15.7; a soft clay 15.7; a rolled gravel 22.0.

`saturated_unit_weight` number · optional · > 0

Saturated unit weight γsat (kN/m³), at least γ and at most γ + 9.81, and more than water's 9.81. Required where the stratum reaches below the water table.

`soil_type` text · required · one of: gravel, sand, silty\_sand, clayey\_sand, silt, clay, rockfill

What the soil is: gravel, sand (clean, fine to coarse, or slightly silty), silty sand, clayey sand, silt or clay; or a quarried rock fill. Each method reads it to know whether it's for this soil (a sand's methods, a clay's), and nothing is assumed without it. A drained stratum may be any type (a clay in the long term, by c' and φ'); an undrained one is a clay or a silt.

`preconsolidation_pressure` number · optional · > 0

Optional: preconsolidation pressure σ'c (kPa), the stratum's stress history: its consolidation takes it, and a clay's OCR for a pile's shaft. Empty, normally consolidated.

`behavior` text · required · = "drained"

`cohesion` number · optional · ≥ 0 · default 0

Cohesion c' (kPa).

`friction_angle` number · optional · > 0 · < 90

Friction angle φ' (deg). Required where a method of the model reads it: a footing's bearing resistance (every drained stratum's) and its sliding (the base stratum's), a wall's always; not where a footing in free mode has its allowable bearing pressure given, no horizontal load, and no strength on its base stratum.

`relative_density` number · optional · ≥ 0 · ≤ 1

Optional, for a gravel, a sand or a silty sand without c': its relative density Dr, from 0 to 1, as the soil study gives it from its SPT, CPT or density tests. It decides only the mode the base on it fails in, by Vesic's chart of the modes of failure in sand (FHWA NHI-06-089 Fig. 8-19; AASHTO Fig. C10.6.3.1.2b-1) at the base's relative depth Df/B\*: where that's local or punching shear, the bearing is checked again with c\* and φ\*, beside the general one; φ' stays its strength. Empty, Vesic's rigidity index judges the mode where the stratum B/2 below the base gives its stiffness (Es and μs), else the general shear alone; past Df/B\* 3.67 the chart puts any sand in local or punching shear.

`stiffness` group · optional

Optional: with the stiffness of every stratum the elastic settlement is computed too.

`soil_modulus` number · required · > 0

The soil's elastic modulus Es (kPa), taken as measured in situ (AASHTO 10.4.6.3: a pressuremeter's, where the deformation is critical).

`poisson_ratio` number · required · ≥ 0 · ≤ 0.5

Poisson's ratio μs.

`consolidation` group · optional

Optional, for a silt or a clay: with these, the stratum's consolidation settlement is computed and added to the settlement (AASHTO 10.6.2.4.3).

`compression_index` number · required · > 0

Compression index Cc, from one-dimensional consolidation tests (AASHTO 10.4.6.3).

`swelling_index` number · optional · > 0

Swelling index Cs. Required with a preconsolidation pressure above the stratum's σ'o.

`initial_void_ratio` number · required · > 0

Initial void ratio eo, at the stratum's initial vertical effective stress (AASHTO 10.6.2.4.3), from the consolidation test.

`coefficient_of_consolidation` number · optional · > 0

Optional: coefficient of consolidation cv (m²/year), for how long the stratum takes; from 1 for a low permeability clay to 100 for an overconsolidated sandy one (Das & Sivakugan, section 2.16). It drains through the faces it shares with a drained soil or the ground surface.

`rock` Rock below the footing's soil (or a wall's): where the soil's settlement stops and the bearing resistance doesn't count it (AASHTO's equations take the soil, the conservative side). A base resting on the rock isn't calculated: it goes on the soil above.

`thickness` number · optional · > 0 · ≤ 1000

Thickness (m), at most 1000 (app.application.bounds).

`behavior` text · required · = "rock"

`undrained` A clay in the short term: its undrained strength, φ = 0.

`thickness` number · optional · > 0 · ≤ 1000

Thickness (m), at most 1000 (app.application.bounds).

`unit_weight` number · required · > 0

Unit weight γ (kN/m³). Without a measurement, AASHTO's traditional values (Table 3.5.1-1): a compacted sand, silt or clay 18.9; a loose sand, silt or gravel 15.7; a soft clay 15.7; a rolled gravel 22.0.

`saturated_unit_weight` number · optional · > 0

Saturated unit weight γsat (kN/m³), at least γ and at most γ + 9.81, and more than water's 9.81. Required where the stratum reaches below the water table.

`soil_type` text · required · one of: clay, silt

What the soil is: a clay or a silt, the soils taken undrained in the short term (a granular soil is always drained, Das & Sivakugan, section 2.22: make the stratum drained).

`preconsolidation_pressure` number · optional · > 0

Optional: preconsolidation pressure σ'c (kPa), the stratum's stress history: its consolidation takes it, and a clay's OCR for a pile's shaft. Empty, normally consolidated.

`behavior` text · required · = "undrained"

`undrained_shear_strength` number · optional · > 0

Undrained shear strength cu (kPa). Required where a method of the model reads it: a footing's bearing resistance on the stratum it rests on, its sliding there, and a wall's always; not where a footing in free mode has its allowable bearing pressure given, no horizontal load, and no strength on its base stratum.

`drained_strength` group · optional

Optional: the clay's effective strength c' and φ', where it could soften and lose strength with time (a stiff fissured or overconsolidated clay, a compacted cohesive fill): its bearing is checked drained as well, under the permanent loads only, and the lower governs (AASHTO 10.6.3.1.2a, C10.6.3.1.1). Empty, the short-term undrained check alone.

`cohesion` number · optional · ≥ 0 · default 0

Cohesion c' (kPa).

`friction_angle` number · required · > 0 · < 90

Friction angle φ' (deg) of the clay in the long term.

`stiffness` group · optional

Optional: with the stiffness of every stratum the elastic settlement is computed too.

`soil_modulus` number · required · > 0

The soil's elastic modulus Es (kPa), taken as measured in situ (AASHTO 10.4.6.3: a pressuremeter's, where the deformation is critical).

`poisson_ratio` number · required · ≥ 0 · ≤ 0.5

Poisson's ratio μs.

`consolidation` group · optional

Optional, for a silt or a clay: with these, the stratum's consolidation settlement is computed and added to the settlement (AASHTO 10.6.2.4.3).

`compression_index` number · required · > 0

Compression index Cc, from one-dimensional consolidation tests (AASHTO 10.4.6.3).

`swelling_index` number · optional · > 0

Swelling index Cs. Required with a preconsolidation pressure above the stratum's σ'o.

`initial_void_ratio` number · required · > 0

Initial void ratio eo, at the stratum's initial vertical effective stress (AASHTO 10.6.2.4.3), from the consolidation test.

`coefficient_of_consolidation` number · optional · > 0

Optional: coefficient of consolidation cv (m²/year), for how long the stratum takes; from 1 for a low permeability clay to 100 for an overconsolidated sandy one (Das & Sivakugan, section 2.16). It drains through the faces it shares with a drained soil or the ground surface.

`water_table` group · optional

null when there is none.

`depth` number · required

Depth below the ground surface on its side (m); negative when the water stands above it.

`loads` list · optional · 0–30 items

Loads on the wall: surcharges on the backfill surface (uniform, highway traffic or a line) and at most one earthquake; often none.

Each item is one of:

`earthquake` A pseudo-static earthquake (Extreme Event I under AASHTO LRFD 10th, 11.6.5): the wall is checked under it too, beside the static case. Mononobe and Okabe (and the MSE wall's checks) read the seismic coefficients kh and kv: kh is the designer's in free mode and, under AASHTO, comes from the site's As (11.6.5.2).

`load_type` text · required · = "earthquake"

`kh` number · optional · > 0 · < 1

Free mode only, and required there: the horizontal seismic coefficient kh (in g) the designer takes for the wall and its backfill, from the site's hazard and the displacement the wall may take. Under AASHTO kh comes from As instead (11.6.5.2).

`peak_ground_acceleration` number · optional · > 0 · < 2

AASHTO only, and required there: As (in g), the design peak ground acceleration coefficient at the ground surface, the risk-targeted spectrum's Sa at 0 s for the site class (AASHTO LRFD 10th, 3.10.4.1). kh0 = As (11.6.5.2.1). Free mode takes the designer's kh instead.

`rock_site` yes or no · optional · default false

AASHTO only: the wall stands on rock, Site Class A, B or B/C (hard to soft rock, Table 3.10.3.1-1): kh0 = 1.2 As (11.6.5.2.1).

`kh_reduction` one of · optional

AASHTO only: how kh comes from kh0 (11.6.5.2.2): none, kh = kh0, the default, a wall that may not move; half, kh = 0.5 kh0, a wall that may slide 25.4 to 50.8 mm or more; newmark, the designer's kh from a Newmark analysis. Wave scattering isn't counted (C11.6.5.2.2: the designer may leave it out, the safe side).

`half` kh = 0.5 kh0 (AASHTO LRFD 10th, 11.6.5.2.2).

`reduction` text · required · = "half"

kh = 0.5 kh0: the wall can slide 25.4 to 50.8 mm or more under the design earthquake and the owner accepts it, without a deformation analysis (11.6.5.2.2).

`newmark` The designer's kh, from a Newmark sliding block analysis.

`reduction` text · required · = "newmark"

kh from the designer's own Newmark sliding block analysis, or one of Appendix A11.5's simplified forms (Kavazanjian et al., Anderson et al., Bray et al.), for the displacement the owner accepts (11.6.5.2.2): the designer's, Rischio computes none of them.

`kh` number · required · > 0 · < 1

The wall's horizontal seismic coefficient kh (in g) that analysis gives, for the wall and its backfill's pressure.

`none` kh = kh0: a wall that may not move (AASHTO LRFD 10th, 11.6.5.2.2), and every nonyielding wall (1.0 kh0, 11.6.5.4).

`reduction` text · required · = "none"

kh = kh0, no reduction: the wall may not move, or doesn't (a nonyielding wall, 11.6.5.4).

`kv` number · optional · ≥ 0 · < 1 · default 0

Vertical seismic coefficient kv (in g), upwards, in both modes: 0 by default, AASHTO's unless the wall is near a fault or a high vertical acceleration comes with the horizontal one (11.6.5.2.1).

`live_load_factor` number · optional · ≥ 0 · ≤ 1 · default 0.5

AASHTO only: γEQ, the live surcharge's load factor at Extreme Event I (Table 3.4.1-1): the share of the traffic on the wall during the earthquake, project-specific; 0.5 by Turkstra's rule (C3.4.1). It sets the eccentricity limit too, the middle 2/3 of the base at 0 to 8/10 at 1 (11.6.5.1). Free mode takes the live surcharge whole.

`surcharge` A load on the backfill surface. All over it from the wall (traffic, storage, a slab) it pushes K q down the whole wall, with the earth pressure (AASHTO LRFD 10th, 3.11.6.1); a line parallel to the wall pushes by elastic theory, in full (an unyielding wall; AASHTO Eq. 3.11.6.2-3, FHWA NHI-06-089 §10.4.3). In free mode, what lies over a cast-in-place wall's heel is left out of what holds it (FHWA-NHI-06-089 §10.5.3), and what lies over an MSE block holds it only where it stays (FHWA-NHI-00-043 §4.2.e).

`load_type` text · optional · = "surcharge" · default "surcharge"

`load_case` text · optional · one of: dead, live · default "live"

Whether the load stays (dead: a building, a fill) or comes and goes (live: traffic, storage), for the codes that factor them apart. Either pushes on the wall. Over an MSE block, a dead one also holds it against sliding and in its eccentricity, in both modes, as FHWA counts a permanent load and AASHTO leaves out only the live one (FHWA-NHI-00-043 §4.2.e, step 4; AASHTO C11.5.6), and holds its reinforcement in pullout (AASHTO 11.10.6.3.2; FHWA GEC 11, Eq. 4-35); a live one bears on the block only for its bearing. Over a gravity, cantilever or gabion wall's heel, free mode takes neither as holding the wall, as FHWA neglects every surcharge within a cast-in-place wall's base (FHWA-NHI-06-089 §10.5.3), where AASHTO counts a dead one.

`distribution` one of · required

`line` A line load parallel to the wall, such as a wall or a rail on the backfill.

`shape` text · required · = "line"

How the load is spread: along a line parallel to the wall.

`line_load` number · required · > 0

Line load P per metre of wall (kN/m).

`wall_distance` number · optional · ≥ 0 · default 0

From the wall's back at its crest to the line (m).

`uniform` A uniform pressure q over all the backfill from the wall (AASHTO LRFD 10th, 3.11.6.1).

`shape` text · optional · = "uniform" · default "uniform"

How the load is spread: uniform, q over all the backfill from the wall.

`surcharge` number · required · ≥ 0

Surcharge q (kPa).

`vehicular` Highway traffic on the backfill: a uniform live surcharge γs heq, heq from AASHTO's table for a retaining wall parallel to the traffic (Table 3.11.6.4.1-2), by the wall's height and its edge's distance from the wall.

`shape` text · required · = "vehicular"

How the load is spread: highway traffic parallel to the wall, a uniform surcharge γs heq over the backfill (AASHTO LRFD 10th, Eq. 3.11.6.4.1-1).

`wall_distance` number · optional · ≥ 0 · default 0

From the wall's back at its crest to the traffic's edge (m), Table 3.11.6.4.1-2's 0, or 0.3048 and more.

`design` group · optional

The mode its checks are judged in, free or a design code, and the designer's limits. Empty, free mode.

`code` text · optional · one of: free\_mode, aashto\_lrfd\_10 · default "free\_mode"

The mode the checks are judged in. free\_mode: no design code; the methods are the designer's (each left by the data, or chosen), each check gives its unfactored factor of safety or its quantity, and only the checks the designer set a limit for (limits) have a verdict; the limits the codes and manuals ask come beside each check as references. aashto\_lrfd\_10: AASHTO LRFD Bridge Design Specifications, 10th edition (2024), load and resistance factor design, each check φRn/ΣγQ ≥ 1, with the methods the code admits.

`limits` number · optional

Optional: the designer's limits, by the check's id (its factor of safety, or its settlement, deflection or eccentricity in m). In free mode, the only checks with a verdict; under a code, in place of the code's, and the answer says what the code asks.

`resistance_factors` number · optional

Optional, with a code of load and resistance factors: the resistance factors φ the designer edited, by the check's id, in place of the code's.

`load_modifier` group · optional

With a code of load and resistance factors: the code's load modifier η = ηD ηR ηI on the strength limit state's factors (under AASHTO LRFD 10th, 1.3.2.1 to 1.3.5), 1.00 each by default.

`ductility` number · optional · ≥ 0.95 · default 1

ηD (AASHTO 1.3.3): 1.00 for conventional designs and details; 1.05 or more for nonductile components and connections; 0.95 or more where ductility-enhancing measures beyond the code's are specified.

`redundancy` number · optional · ≥ 0.95 · default 1

ηR (AASHTO 1.3.4): 1.00 for conventional redundancy, and always for a footing or a pile, whose φ already accounts for it (10.5; another value is refused there, and a pile's φ for few elements under its support is redundancy\_factor's); 1.05 or more for nonredundant members; 0.95 or more for exceptional redundancy.

`importance` number · optional · ≥ 0.95 · default 1

ηI (AASHTO 1.3.5): 1.00 for typical bridges; 1.05 or more for critical or essential bridges; 0.95 or more for relatively less important ones, as the Owner classifies them.

---

Source: https://rischio.io/docs/retaining-wall/inputs/