A retaining wall's base as a strip footing under an eccentric, inclined load: Vesic's general equation on the effective width, the strata below.

Rischio checks the base of the wall as a strip footing, under the resultant of the forces in [Stability](https://rischio.io/docs/retaining-wall/theory/stability/). AASHTO’s 11.6.3.2 sends a wall’s bearing on soil to the footing’s, and the base goes through the footing’s own code; this page covers what is particular to the wall, and the rest is in [Footings › Bearing capacity](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/).

## The base as a strip footing

The base is a strip footing of width $B$ at depth $D_f$, the ground in front of the toe, under $\Sigma V$ at an eccentricity $e$ and $\Sigma H$. $\Sigma V$ takes what bears on the base over the heel, which sliding and the eccentricity leave out: a surcharge there (AASHTO C11.5.6, Fig. C11.5.6-3) and each line load within the base’s width (FHWA NHI-06-089, §10.5.3). A dead one is always there, as ES under AASHTO; a live one comes and goes on its own (3.4.1), and the bearing takes it in or out, whichever is worse, its inertia with it under an earthquake. Its nominal resistance $q_n$ comes from AASHTO’s Eq. 10.6.3.1.2a-1, in free mode as under AASHTO, on the effective width $B' = B - 2e$, with the $c$ and $\phi$ of the stratum the base rests on:

$$
q_n = c N_c i_c + \gamma D_f N_q d_q i_q C_{wq} + \tfrac{1}{2} \gamma B' N_\gamma i_\gamma C_{w\gamma}
$$

The shape factors are 1 for a strip. $N_c$, $N_q$ and $N_\gamma$, the depth factor $d_q$, the inclination factors with $\Sigma H$ and $\Sigma V$, and the water factors are the footing’s, in [Vesic’s general equation](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/#vesics-general-equation-the-default-under-aashto). $d_q$, at most 1.4, counts the shear of the soil in front of the toe, over the base, only where **Soil in front stays** is checked: that soil stays through the wall’s life, with no scour, excavation or trench to take it, and isn’t weaker than the stratum below (10.6.3.1.2a). Unchecked, the default, $d_q = 1$, as for a toe that may be dug out or scoured.

The factor of safety weighs $q_n$ against the equivalent uniform pressure on that width, as for a footing on soil:

$$
q_{eq} = \frac{\Sigma V}{B'}, \qquad FS = \frac{q_n}{q_{eq}}
$$

UFS 3-220-20 (§4-5.1.4) and FHWA NHI-06-089 (Fig. 10-17, after NAVFAC 1986b) take the uniform pressure for a wall on soil: a soil yields under the toe and the failure takes the whole effective width, which $q_n$ already counts. Under AASHTO the check is $\phi_b q_n$, $\phi_b = 0.55$, against the factored $V/(B - 2e)$ ([AASHTO LRFD](https://rischio.io/docs/reference/aashto-lrfd/)).

With $e \ge B/2$ the resultant leaves the base: there is no contact pressure, and the factor of safety is 0.

## The water under the base

The water factors take the water the base stands in, the same water whose uplift pushes on it ([Stability](https://rischio.io/docs/retaining-wall/theory/stability/)). Where the water in front reaches the base, that is the water. Where the water behind stands above the base and the water in front doesn’t reach it, the uplift still pushes from the heel, so the soil under the base isn’t dry: the bearing takes the water behind at the base’s level, $D_w = D_f$, which gives $C_{wq} = 1$ and $C_{w\gamma} = 0.5$ (Table 10.6.3.1.2a-2); with the base at the ground, $D_f = 0$, the table’s first row gives $C_{wq} = 0.5$, which multiplies $q = 0$. AASHTO designs a spread footing “in consideration of the highest anticipated groundwater table”, whose influence on the bearing resistance and the settlement “shall be considered” (10.6.1.6), and asks for the effects of water seeping under a wall (11.6.3.4). How high seeping water stands under a base takes a flow net, which Rischio doesn’t draw (C11.6.3.4). The base’s level is where the uplift line leaves the water at the toe, and with the ground in front dry it gives the lowest water factors the table holds. The settlement takes the same water, so a stratum below the base that consolidates needs its saturated unit weight.

For example, a cantilever 4.5 m high on sand, its base 3.8 m wide and 1.2 m deep, with the water 2.0 m below the crest behind it and none in front: the uplift is 24.5 kPa at the heel, and the bearing takes $C_{wq} = 1$ and $C_{w\gamma} = 0.5$.

## Local or punching shear

The base is judged as a footing is ([Local or punching shear](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/#local-or-punching-shear)). Where the stratum it rests on is a sand with its relative density, it reads Vesic’s chart as a strip: $B^* = 2B'$, with $B' = B - 2e$ of each case, and $D_f$ the base’s depth below the ground in front. Otherwise, where the stratum $B/2$ below the base gives its stiffness, Vesic’s rigidity index decides, on the base’s width $B$, the same in every case; with neither, the general bearing stands alone. Where the base may fail in local or punching shear, Results adds **Bearing capacity, local shear**, the same equation with $c^*$ and $\phi^*$ against the same limit, and under an earthquake its own check too. An MSE wall’s block reads the chart the same way on $L' = L - 2e$, with $D_f$ its embedment, though its $q_n$ leaves the embedment out, and the index on its length $L$, its stress from the block’s base down. Neither reads the water, in front or behind: the index takes its stress by the moist weights, as a footing’s does.

For example, a cantilever 4.5 m high with no water, its base 3.8 m wide and 1.2 m deep on a sand with $\phi = 32°$ and $D_r = 0.50$, a sand backfill with $\phi = 34°$: $B' = 3.79$ m, $B^* = 7.58$ m and $D_f/B^* = 0.16$, where the line is at 0.698, so the base is in local shear. In free mode $q_n$ drops from 874 to 261 kPa, and the factor of safety from 12.27 to 3.67.

## The strata below

Like a footing, the base sees the strata below it: a weaker stratum within the critical depth (a softer clay under a clay, past it too, to the cap of its $N_m$) lowers $q_n$ by AASHTO’s 10.6.3.1.2d to f ([Footings › Two strata](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/#two-strata)), under an earthquake too. A stronger stratum below and rock under the strata aren’t counted, the conservative side.

## An allowable bearing pressure

A soil study’s allowable bearing pressure for the wall’s base, or a presumptive value, goes in the wall’s **Allowable bearing pressure**, $q_a$, beside its embedment. AASHTO’s 11.6.2.2 sends a wall’s service limit state to the footing’s 10.6.2.5 (11.10.4.1 and 11.11.3 do the same for an MSE wall and a gabion wall), so the base is checked as a strip footing at Service I, by the footing’s own check ([Footings › An allowable bearing pressure](https://rischio.io/docs/shallow-foundation/theory/bearing-capacity/#an-allowable-bearing-pressure)). The pressure is the total one at the base, with what the wall, the soil over its heel and the surcharges over it weigh, less the water’s uplift. In free mode a concrete or gabion wall’s check takes the pressure at its most loaded edge, the greatest ordinate of the base’s linear pressure diagram, $q_{max} = (\Sigma V/B)(1 + 6e/B)$, or the triangle on the part in contact past the middle third, $2\Sigma V/[3(B/2 - e)]$. A live line load over the heel is in or out, whichever gives the greater pressure, as the bearing above searches it (AASHTO 3.4.1). An MSE block is a flexible mass that develops no triangular pressure (AASHTO C11.10.5.4), so in free mode its check takes its own uniform pressure, $\sigma_v$ on $L - 2e$, the one its bearing takes (11.10.5.4), with a negative $e$ taken as 0. Under AASHTO every wall takes the uniform pressure on $B' = B - 2e$ at Service I (an MSE block’s $L' = L - 2e$, with $L'_{min}$ beside it), at the service limit state only (10.5.2.1), its live surcharge and each live line load over the heel in or out, whichever gives the greater pressure (3.4.1). A gabion wall takes its bottom level. Where the resultant falls outside the base, nothing is checked, and the warning that says so names the value. The bearing capacity above still applies, and a wall’s foundation always gives its strength, which its sliding needs.

## Settlement

Where its foundation strata have their moduli or their consolidation, the base also settles as a strip footing at Service I, by the footing’s own methods (AASHTO 11.6.2.2 sends it to 10.6.2.4; [Footings › Settlement](https://rischio.io/docs/shallow-foundation/theory/settlement/)). In both modes it settles on $B' = B - 2e$ with its load at the centre, the uniform pressure FHWA takes “for soils and settlement analysis” (FHWA-NHI-06-089, Fig. 10-17) and the effective area AASHTO’s 10.6.1.3 asks for.

---