# Earth pressure

Rankine, with or without cohesion, or Coulomb behind a retaining wall: the wall's back, a sloping backfill, water, surcharges and an earthquake.

Behind the wall, the backfill pushes with its active pressure, and the water and the surcharge add to it. By the data, the active pressure follows the wall’s heel and the backfill; the wall’s methods choose the other, and the **Results** tab shows the one not chosen beside it, as a reference, where the soil takes it. The soil in front of the wall isn’t counted, the safe side AASHTO allows (10.6.3.4, 11.6.3.5).

## Active pressure methods

-   **Rankine**: on the virtual back, the vertical plane through the end of the heel, with the soil between the wall and it counted as wall weight. The wall can yield a little, enough for the backfill to reach its active state: the usual case for a cantilever or gravity wall. By the data over a long heel, one the Rankine wedge from its end misses the wall (Das & Sivakugan, Eq. 17.1; AASHTO Fig. C3.11.5.3-1).
-   **Coulomb**: on the wall’s back, with the friction $\delta'$ between the wall and the backfill. For a granular backfill; by the data over a short heel or a back without one, such as a gravity or gabion wall’s (AASHTO C3.11.5.3; FHWA NHI-06-089, §10.5.3).
-   **Rankine with cohesion**, in free mode only: Rankine’s on the virtual back, with each drained stratum’s $c'$ lowering the pressure (Bell’s equation), over a level backfill. Only the designer chooses it, never the data ([Rankine with cohesion](#rankine-with-cohesion)).

Under AASHTO the same rule is the code’s (C3.11.5.3), and Rankine chosen under a granular backfill where the heel is short, or there is none, is refused. Rankine with cohesion doesn’t appear under AASHTO. The checks the backfill pushes on, sliding, eccentricity and bearing, say which pressure they come from.

### The wall’s back

Coulomb takes the wall’s back as a plane. A gravity wall, a gabion wall with an aligned back or an L wall without a heel has one. When the back has a heel or steps, Rischio takes the plane from the heel to the back corner of the crest, as AASHTO LRFD does for modular walls with an irregular back and Maccaferri for gabion walls, and the soil between the wall and that plane counts as wall weight. The surface past the crest’s back is the active wedge’s top: a surcharge there reaches the wall only through the thrust, which already carries it, so its weight between the crest and the heel isn’t counted on the wall (Das & Sivakugan, Fig. 16.15; FHWA NHI-06-089, §10.5.3). Its inclination from the vertical is

$$
\theta = \tan^{-1}\frac{x_{heel} - x_{crest}}{H'}
$$

with $H'$ the height of the wall. A heel can also be long enough for the soil over it to move with the wall: then the Rankine wedge from the heel misses the wall, and AASHTO takes Rankine on the virtual back, which Coulomb gives too with $\delta' = \beta$. The wedge’s outer plane leaves the heel at (Das & Sivakugan, Eq. 17.1)

$$
\eta = 45^\circ + \frac{\beta}{2} - \frac{\phi'}{2} - \frac{1}{2}\sin^{-1}\frac{\sin\beta}{\sin\phi'}
$$

from the vertical, with the bottom backfill stratum. If it cuts the wall, the heel is short. With Coulomb over a long heel, the thrust is Rankine’s on the virtual back, and a warning says so; with Rankine over a short heel, it’s computed as chosen, on the safe side, and Results says the data would take Coulomb ([Read the results](https://rischio.io/docs/studio/results/#the-methods)).

### Coulomb

Each backfill stratum’s coefficient, with $\beta$ the backfill slope:

$$
K_a = \frac{\cos^2(\phi' - \theta)}{\cos^2\theta\cos(\delta' + \theta)\left[1 + \sqrt{\dfrac{\sin(\phi' + \delta')\sin(\phi' - \beta)}{\cos(\delta' + \theta)\cos(\theta - \beta)}}\right]^2}
$$

At a depth $z$ below the crest, $\sigma_a = \left(\sigma'_v + q\,\dfrac{\cos\theta}{\cos(\theta - \beta)}\right)K_a$, which integrates to $\tfrac{1}{2}K_a\gamma H'^2$ at $H'/3$ and the surcharge’s $K_a H' q\cos\theta/\cos(\theta - \beta)$ at $H'/2$ (Das & Sivakugan, Eqs. 16.36 to 16.38). The thrust leans $\delta'$ from the normal to the back, $\theta + \delta'$ from the horizontal: its horizontal part pushes the wall, and its vertical part bears down where it meets the back, the backfill’s at its own height and the surcharge’s at its own (why the surcharge’s leans too: [A uniform surcharge and a line load](#a-uniform-surcharge-and-a-line-load)). Where the strata lean differently (each its own $\delta'$), each part acts at the centroid of its own pressure: the horizontal part at $y_a = \Sigma P_{a,h,i}\,y_i / P_{a,h}$, its moment about the toe, and the vertical part at $y_{a,v} = \Sigma P_{a,v,i}\,y_i / P_{a,v}$, where it meets the back. In one stratum the two heights are one.

### Wall friction

The friction is given as $\delta'/\phi'$, the same for every stratum, 0.5 by default. Das & Sivakugan design with ½ to ⅔ of $\phi'$; ½ gives more horizontal thrust, the safe side. For the back of a gabion wall, UFC 3-220-20 takes $\tan\delta' = 0.9\tan\phi'$ and Maccaferri $\delta' = \phi'$.

## Active thrust

Rankine’s active thrust acts on the virtual back, from the base to the backfill surface. Its height is

$$
H' = H + b\tan\beta
$$

with $b$ the horizontal distance from the back of the crest to the virtual back. Each backfill stratum has its own coefficient, defined for $\beta \le \phi$ (a steeper backfill is refused: it would slide on its own) and equal to $\tan^2(45^\circ - \phi/2)$ on level ground:

$$
K_a = \cos\beta\,\frac{\cos\beta - \sqrt{\cos^2\beta - \cos^2\phi}}{\cos\beta + \sqrt{\cos^2\beta - \cos^2\phi}}
$$

At a depth $z$ below the top of the virtual back, the pressure is

$$
\sigma_a = (\sigma'_v + q)\,K_a
$$

with $\sigma'_v$ the vertical effective stress ($\gamma$ above the water table, $\gamma'$ below), so a surcharge adds $K_a q$ all the way down. The cohesion takes no part, as in AASHTO’s earth pressure (3.11.5.1, C3.11.5.3), the safe side, unless the designer counts it in free mode (below). The diagram breaks at each stratum boundary and at the water table. The thrust $P_a$ is parallel to the backfill surface: $P_a\cos\beta$ pushes the wall, and $P_a\sin\beta$ bears down on the virtual back, at $x = B$.

### Rankine with cohesion

In free mode the designer can count a drained backfill’s cohesion. The pressure is Rankine’s on the virtual back with each stratum’s $c'$ (Bell’s equation; Das & Sivakugan, Eq. 16.11):

$$
\sigma'_a = (\sigma'_v + q)\,K_a - 2c'\sqrt{K_a}
$$

with $K_a = \tan^2(45^\circ - \phi'/2)$, so only over a level backfill: on a sloping one the option is dimmed. Near the top the equation goes negative, as if the soil pulled on the wall; instead, the soil cracks away from it. The pressure is zero down to the depth of that tension crack, which for one dry stratum without a surcharge is (Eq. 16.12)

$$
z_c = \frac{2c'}{\gamma\sqrt{K_a}}
$$

and the thrust is the area of the diagram below it (Eq. 16.14). The crack holds no water: Rischio takes the backfill as drained, which AASHTO asks of every wall (11.6.6). A surcharge closes part of the crack, a deeper stratum in tension pushes nothing either, and an undrained stratum pushes as with Rankine, with $K = 1$ and its $s_u$ left out. Where the crack reaches the base, the backfill holds itself up and its soil doesn’t push: without water or a line load behind it, nothing pushes the wall to slide, and the result says so. Under an earthquake, Mononobe and Okabe’s thrust takes $\phi'$ alone, as in every method, and its increment over this static thrust gives back what the cohesion took off.

With a $c'$ above about 5 kPa the crack runs deep, and FHWA asks either to reduce $c'$ towards the surface or to take the effective pressure as never less than $5z$ kPa, with $z$ the depth in m (NHI-06-089, p. 10-15). Rischio takes the second in each stratum whose $c'$ passes 5 kPa, so that stratum has no crack:

$$
\sigma'_a = \max\left[5z,\ (\sigma'_v + q)\,K_a - 2c'\sqrt{K_a}\right]
$$

A $c'$ reduced near the surface, FHWA’s other way, is modelled as a top stratum of its own.

AASHTO doesn’t admit it, so it doesn’t appear under the code. Its active pressure has no cohesion term (3.11.5.1, 3.11.5.3), and its commentary warns that a cohesive backfill’s pressure is highly uncertain: the soil shrinks and swells, cracks, and creeps until its pressure nears the one at rest (C3.11.1).

## Water

Below the water table behind the wall, the soil pushes with $\gamma'$ and the water on its own, with its hydrostatic thrust at a third of its height $h_w$ above the base.

## A uniform surcharge and a line load

A uniform surcharge over the whole backfill, from the wall on (traffic, storage, a slab), adds $K_a q$ to the active pressure all the way down, as above (AASHTO 3.11.6.1). Its thrust leans as the earth’s, at $\delta'$ on Coulomb’s back and at $\beta$ on Rankine’s, so its vertical part resists sliding and overturning, at its own load factor under AASHTO. AASHTO’s Fig. 11.10.5.2-1 draws a traffic surcharge’s thrust that way, its vertical part resisting, as “a Coulomb external load model consistent with the analysis of all other gravity walls” (C3.11.5.8.1), and FHWA’s worked example counts that vertical part in its sliding resistance (FHWA-HIF-24-002, Example C1, pp. C-7 and C-8). 3.11.6.1 calls the surcharge’s pressure “a constant horizontal earth pressure”, and read literally it would leave the thrust horizontal, the more conservative reading; “horizontal” is also AASHTO’s name for the earth’s own load, EH, which its figures lean at $\delta$ (Figs. C11.5.6-1 and -2), and Rischio follows the code’s figure and FHWA’s example. Highway traffic is one, live: $q = \gamma_s h_{eq}$, with $h_{eq}$ from AASHTO’s table for a wall parallel to the traffic (Table 3.11.6.4.1-2), by the wall’s height and the traffic’s distance from its back. A line load parallel to the wall, such as a wall or a rail on the backfill, pushes by elastic theory instead, AASHTO’s Eq. 3.11.6.2-3 at every distance:

$$
\Delta p_h = \frac{4 Q X^2 Z}{\pi R^4}
$$

with $Q$ the load per metre of wall, $X$ its distance from the plane, $Z$ the depth below the plane’s top and $R = \sqrt{X^2 + Z^2}$ (Das & Sivakugan’s Eq. 16.40, its denominator squared, as the book misprints it). Rischio integrates $\Delta p_h$ down the plane for the thrust $P_q$ and its height $y_q$ above the base.

The solution is for a wall that doesn’t yield, and Rischio takes it in full, as FHWA NHI-06-089 does (§10.4.3). It acts on the same plane as the active pressure, the vertical through the heel or the wall’s back, and the load’s distance is measured from that plane. What lies over the heel, between the wall and the plane, pushes nothing on it, and its weight never holds the wall in sliding or the eccentricity, which it would resist (FHWA NHI-06-089, §10.5.3). Its weight bears in the [bearing](https://rischio.io/docs/retaining-wall/theory/bearing-capacity/#the-base-as-a-strip-footing) and on a cantilever’s [footing](https://rischio.io/docs/retaining-wall/theory/structural/#the-toe-and-the-heel), a live one in or out, whichever is worse, and under an earthquake its inertia pushes the wall ([Under an earthquake](#under-an-earthquake)). The solution is for a level surface, so a line load on a sloping backfill is refused.

## Under an earthquake

With an earthquake among the wall’s loads, the wall is also checked under it, pseudo-statically, beside the static case, as AASHTO LRFD 10th asks (11.6.5, Extreme Event I): the seismic coefficient $k_h$ acts on the wall and on its backfill. In free mode $k_h$ is the designer’s, from the site’s hazard and the displacement the wall may take. Under AASHTO it comes from the site’s $A_s$ (11.6.5.2): $k_{h0} = A_s$, or $1.2A_s$ for a wall on rock (Site Class A, B or B/C), and $k_h = k_{h0}$ for a wall that may not move, $0.5k_{h0}$ for one that may slide 25 to 50 mm, or the designer’s $k_h$ from a Newmark analysis (11.6.5.2.2). $k_v$, upwards, is 0 unless the designer gives it, in both modes. The thrust $P_{AE}$ is Mononobe and Okabe’s on a cohesionless, dry backfill (11.6.5.3, A11.3.1), and behind a broken back the Coulomb trial wedge’s (C11.6.5.3). The wall’s inertia adds to it (11.6.5.1), $P_{IR} = k_h\,(W_w + W_s + W_q + \Sigma W_l)$: the wall’s weight, the soil’s over the heel, and a uniform surcharge’s and each line load’s on that soil, which swing with it, in phase with the wall (C11.6.5.1), their live part at $\gamma_{EQ}$ under AASHTO and whole in free mode. A line load’s weight still never holds the wall: it bears in the bearing only. Where the pressure acts on the wall’s own back, a surcharge past the crest stands on the active wedge, its inertia already in $P_{AE}$. Each check takes the worse of AASHTO’s two combinations of the thrust and the inertia. In free mode the checks are unfactored factors of safety, with AASHTO’s Extreme Event I limits beside them.

Mononobe and Okabe’s coefficient, with $\theta' = \tan^{-1}[k_h/(1 - k_v)]$ the inertia angle ($k_v$ upwards, 11.6.5.2.1), $\beta$ the backfill slope and $\theta$ the back’s inclination:

$$
K_{AE} = \frac{\cos^2(\phi' - \theta - \theta')}{\cos\theta'\cos^2\theta\cos(\delta' + \theta + \theta')\left[1 + \sqrt{\dfrac{\sin(\phi' + \delta')\sin(\phi' - \beta - \theta')}{\cos(\delta' + \theta + \theta')\cos(\beta - \theta)}}\right]^2}
$$

Its root needs $\phi' \ge \theta' + \beta$: a weaker backfill can’t hold itself under that earthquake, and the model is refused.

---

Source: https://rischio.io/docs/retaining-wall/theory/earth-pressure/