Rischio
Start free

Soil bearing capacity calculator (Terzaghi and Meyerhof)

Free soil bearing capacity calculator for square, rectangular and strip footings: ultimate and allowable capacity and the factor of safety, by Meyerhof.

Úsala en español

Enter a footing, its load and the soil under it. Rischio’s engine works out the ultimate bearing capacity with Meyerhof’s general equation, as the studio does in free mode. It’s free and needs no account.

Calculator · Rischio's engine · general bearing capacity equation

Footing
Geometry
m
m
Load
kN
kN
kN·m
Soil
kN/m³
kPa
°
Water
Water table

These data give no result: check the values.

Rischio's engine calculated this. In the studio you keep the model, change it on the drawing and get the calculation report, every step shown.

Start free

This calculator is offered for information and technical support. It doesn't replace professional judgment or the reviews due, and its use is the user's responsibility.

How it calculates

The engine uses Meyerhof’s general bearing capacity equation, the one the studio takes in free mode: Terzaghi’s three terms with shape, depth and inclination factors, on the effective footing Meyerhof proposed.

qu=c′NcFcsFcdFci+qNqFqsFqdFqi+12γ′B′NγFγsFγdFγiq_u = c' N_c F_{cs} F_{cd} F_{ci} + q N_q F_{qs} F_{qd} F_{qi} + \tfrac{1}{2} \gamma' B' N_\gamma F_{\gamma s} F_{\gamma d} F_{\gamma i}
  • qq is the effective vertical stress at the base, the weight of the soil above it less the pore pressure, and γ′\gamma' the average unit weight from the base down BB: γ\gamma above the water table and γsat−γw\gamma_{sat} - \gamma_w below it.
  • The bearing capacity factors are Reissner’s, Prandtl’s and Vesić’s: Nq=tan⁡2(45°+ϕ′/2) eπtan⁡ϕ′N_q = \tan^2(45° + \phi'/2)\,e^{\pi \tan\phi'}, Nc=(Nq−1)/tan⁡ϕ′N_c = (N_q - 1)/\tan\phi' and Nγ=2(Nq+1)tan⁡ϕ′N_\gamma = 2(N_q + 1)\tan\phi'.
  • The shape factors are De Beer’s, Fcs=1+(B′/L′)(Nq/Nc)F_{cs} = 1 + (B'/L')(N_q/N_c), Fqs=1+(B′/L′)tan⁡ϕ′F_{qs} = 1 + (B'/L')\tan\phi' and Fγs=1−0.4 B′/L′F_{\gamma s} = 1 - 0.4\,B'/L', all 1 for a strip. The depth factors are Hansen’s, Fqd=1+2tan⁡ϕ′(1−sin⁡ϕ′)2Df/BF_{qd} = 1 + 2\tan\phi'(1 - \sin\phi')^2 D_f/B up to Df/B=1D_f/B = 1 and with tan⁡−1(Df/B)\tan^{-1}(D_f/B) beyond, Fcd=Fqd−(1−Fqd)/(Nctan⁡ϕ′)F_{cd} = F_{qd} - (1 - F_{qd})/(N_c\tan\phi') and Fγd=1F_{\gamma d} = 1. The inclination factors are Meyerhof’s, by the load’s inclination β=tan⁡−1(H/V)\beta = \tan^{-1}(H/V): Fci=Fqi=(1−β/90°)2F_{ci} = F_{qi} = (1 - \beta/90°)^2 and Fγi=(1−β/ϕ′)2F_{\gamma i} = (1 - \beta/\phi')^2.
  • An eccentric load works on Meyerhof’s effective footing, B′=B−2eBB' = B - 2e_B and L′=L−2eLL' = L - 2e_L.

The allowable bearing capacity is qu/3q_u/3. With the load centred, the factor of safety compares quq_u with the pressure under the base, qmaxq_{max}. With an eccentric load it compares quq_u with the load spread over the effective footing, qeq=V/(B′L′)q_{eq} = V/(B'L'). Either way it asks for 3 or more. The method, with every factor and when it applies, is in the bearing capacity theory of the docs; under AASHTO, the studio takes the code’s own equation instead.

Terzaghi’s equation, to compare

Terzaghi’s equation (1943) is where the general one comes from. It was written for a strip footing under a vertical, centred load:

qu=c′Nc+qNq+12γBNγq_u = c' N_c + q N_q + \tfrac{1}{2} \gamma B N_\gamma

For a square footing, he raised the cohesion term by 1.3 and brought the weight term down to 0.4: qu=1.3 c′Nc+qNq+0.4 γBNγq_u = 1.3\,c' N_c + q N_q + 0.4\,\gamma B N_\gamma, with his own NγN_\gamma, which he tabulated. It has no depth or inclination factors, so for a deep footing or an inclined load the general equation, which the calculator works out, is the one to trust.

How to use it

  1. Pick the footing: square, rectangular or strip. A strip’s load goes per metre of its length.
  2. Give its width BB, its length LL if it’s rectangular, and how deep its base is, DfD_f.
  3. Enter the load at the base: the vertical load and, if there are any, the horizontal load and the moment along the width.
  4. Describe the soil (its unit weight, cohesion and friction angle) and the water table, if it’s near.

The results show quq_u, the allowable capacity, qmaxq_{max} and the factor of safety, with every factor of the equation and a drawing of the footing with its contact pressure. To keep the footing, try other loads or get a calculation report with every step, design it in Rischio’s footing tool.

Frequently asked questions

How do you calculate the bearing capacity of soil?

With a bearing capacity equation: Terzaghi’s for a strip under a vertical load, or the general equation for any footing, depth and load. Both add what the soil’s cohesion, the weight of the soil above the base and the soil’s own weight under it can carry before the ground shears.

What is the allowable bearing capacity?

The ultimate bearing capacity divided by a factor of safety, usually 3 for foundations: qall=qu/3q_{all} = q_u/3. A design also has to keep settlement within limits, which can govern before bearing does.

What is a good soil bearing capacity?

It depends on the soil and on the footing, which is why it’s calculated. As an order of magnitude, the presumptive values of the International Building Code, for use without a geotechnical study, go from 1,500 psf (about 72 kPa) for clays and silts to 2,000 psf (96 kPa) for sands, 3,000 psf (144 kPa) for gravels and 12,000 psf (575 kPa) for crystalline bedrock.

Which soil has the best bearing capacity?

Rock, then dense gravels and sands, then stiff clays. Soft clays, loose sands and organic soils carry the least, and often call for a deep foundation or ground improvement.

What is the difference between Terzaghi’s and Meyerhof’s equations?

Meyerhof’s general equation adds shape, depth and inclination factors to Terzaghi’s three terms, so it covers rectangular footings, deeper bases and inclined or eccentric loads. For a strip footing near the surface under a vertical load, the two come out close.

More calculators

All calculators