Rischio
Start free

Deep Foundation: Definition, Types and When to Use One

What a deep foundation is, when one is needed and the types of deep foundation: driven piles, drilled shafts, micropiles, CFA piles and caissons.

10 min readLéelo en español
0 kPa50 kPa87 kPaSingle pileFS 4.31 ≥ 3.025 kPa83 kPaPile groupFS 12.26 ≥ 3.0
In this article
  1. How a deep foundation carries load
  2. When a deep foundation is needed
  3. Types of deep foundation
  4. Driven piles or drilled shafts
  5. How a deep foundation is designed
  6. Design deep foundations in Rischio
  7. Frequently asked questions
  8. References

A deep foundation carries the load of a structure through weak or compressible ground to soil or rock that can take it, some depth below the structure. AASHTO LRFD defines it as “a foundation that derives its support by transferring loads to soil or rock at some depth below the structure by end bearing, adhesion or friction, or both” (Article 10.2). Driven piles, drilled shafts and micropiles are the deep foundations AASHTO’s Section 10 designs, in Articles 10.7, 10.8 and 10.9.

This guide covers how a deep foundation carries its load, the situations that call for one, the types of deep foundation and how to choose between them, and how one is designed.

How a deep foundation carries load

A deep foundation takes its load in two ways, and most use both:

  • Toe bearing, or end bearing: the base of the element rests on a dense or strong stratum, which carries the load in compression.
  • Shaft resistance, or side resistance: the soil along the embedded length resists by friction or adhesion. AASHTO calls a pile that gets its support mainly this way a friction pile.

The ultimate axial capacity is the sum of the two:

Qu=Qp+QsQ_u = Q_p + Q_s

The names change with the type. FHWA’s manuals speak of shaft resistance and toe resistance for driven piles, and of side resistance and base (or tip) resistance for drilled shafts; they are the same two mechanisms.

When a deep foundation is needed

FHWA’s Soils and Foundations manual (Chapter 9) lists the situations where shallow foundations are the wrong choice:

  • The upper strata are too weak or compressible for the load, the most common case. The deep foundation passes through them to a dense layer and bears at its toe or, with no such layer within a reasonable depth, sheds the load gradually along its shaft.
  • The loads aren’t only vertical. Footings resist inclined, lateral and uplift loads and overturning poorly, while a deep foundation resists uplift along its shaft and lateral load in bending, or as a group of vertical and battered piles.
  • Scour can remove the soil around a footing in a stream, so the foundation has to reach below the scour depth and develop its full capacity there.
  • Soils that can liquefy in an earthquake lose lateral and shaft resistance.
  • An excavation planned next to the structure, in a city, would otherwise mean underpinning it later.
  • Expansive or collapsible soils move with the seasons, and the foundation carries the load below the zone that moves.
  • Bridge piers have to resist vessel impact, through fender systems or the pier’s own foundation.

Shallow vs deep foundations walks through the decision between the two, with a worked example for one column.

Types of deep foundation

FHWA classifies deep foundations by material (concrete, steel, timber, composite), by configuration, and by how they are installed and with what equipment: driven, with or without a mandrel, or drilled. Grouped by installation, the deep foundation systems in use are these.

weak stratadense stratumToe bearingno dense stratumShaft resistanceDriven pileDrilled shaftMicropilesOpen caisson
How a deep foundation carries its load (above) and how four types are installed (below).
TypeHow it’s installedSize or formWhat it’s chosen for
Driven pilesDriven by a hammer or a vibratorPrecast concrete, steel H and pipe, timberWeak soils near the surface over a bearing layer; their capacity can be checked as they are driven
Drilled shaftsDrilled, then filled with concrete and a cageAbout 750 mm and largerLarge loads on one element, no driving vibration
MicropilesDrilled, reinforced and groutedLess than 300 mmTight access, low headroom, underpinning
Continuous flight auger (CFA) pilesDrilled with a hollow auger, concrete pumped as it comes out0.3 to 0.9 mSpeed, low noise and vibration
CaissonsSunk by excavating inside or under themVery largeBridge piers in deep water

Driven piles

Driven piles are preformed and driven into the ground: precast or prestressed concrete, steel H-piles and pipe piles, timber, and composite sections. Precast concrete, closed-end pipe and timber push the soil aside as they go in (displacement piles); H-piles and open-end pipe displace little. Driving gives a check on every pile, since the blows needed to drive it relate to its capacity, but it is noisy and sends vibration into the ground. AASHTO designs them in Article 10.7, and FHWA’s GEC 12 covers their design and construction. Pile foundation goes through the types of piles and works out a driven pile’s capacity by hand.

Drilled shafts

A drilled shaft is cast in place: a hole is drilled, kept open with casing or slurry where the ground needs it, and filled with concrete, usually around a reinforcing cage. The same element is called a bored pile, a drilled pier, a caisson or, in Caltrans’ terms, a cast-in-drilled-hole pile. Das and Sivakugan put its diameter at about 750 mm or more, sometimes as small as 305 mm. Among its advantages they list:

  • one large shaft can replace a group of piles and their cap;
  • it is easier to build in dense sand and gravel than a pile is to drive;
  • no hammer noise or ground vibration reaches nearby structures, and there is no heave of clay around piles already in;
  • the base can be enlarged for uplift, and the soil under it can be inspected;
  • it resists lateral load well.

AASHTO designs drilled shafts in Article 10.8, following FHWA’s GEC 10 (Brown, Turner and Castelli, 2010).

Micropiles

A micropile is “a small-diameter drilled and grouted non-displacement pile (normally less than 12.0 in.) that is typically reinforced”, in AASHTO’s definition: under 300 mm. It is built by drilling a hole, placing a steel bar or tube, and grouting. FHWA’s micropile manual notes that micropiles can carry significant axial loads and moderate lateral loads, disturb the ground and the structures around them very little, go in at any angle, and can be installed where access is restricted and in any soil. They are designed in AASHTO’s Article 10.9.

CFA piles

A continuous flight auger pile is drilled to full depth in one pass. The soil on the auger’s flights holds the hole open, and as the auger comes out, concrete or grout is pumped through its hollow stem to the base, so the hole is never left unsupported. The cage goes into the fresh concrete afterwards. FHWA’s GEC 8 gives diameters of 0.3 to 0.9 m and lengths up to about 30 m. CFA piles avoid driving noise and vibration, splices and cutoffs; the drawbacks it names are spoil to dispose of and quality checks less reliable than a driven pile’s.

Caissons

In the American usage, “caisson” often means a drilled shaft. FHWA’s GEC 10 notes that the term more accurately names very large footings sunk into position by excavating through or under them: the pneumatic caissons of the 19th-century bridges, which are rare today, and the open-well caissons still occasionally used for bridges in deep water. An open-well caisson is a box, open at the top and bottom, with dredge wells through which the soil is dug out to sink it.

Driven piles or drilled shafts

FHWA’s manual says the subsurface conditions are the first thing to consider when choosing the pile type, and its Table 9-1 sets driven piles against drilled shafts for common problems:

Ground conditionDriven pilesDrilled shafts
Boulders over the bearing stratumHeavy nondisplacement pile with a reinforced tip, and predrilling in the contractA large diameter may be feasible, depending on the boulders
Loose sandTapered pile, for more shaft frictionNeeds casing or slurry, which makes it costlier
Deep soft clayRough concrete pile, for adhesionPossible, but casing or slurry makes it costlier
Artesian pressureNo mandrel-driven thin shells; closed-end pipe may heaveNeeds slurry drilling
ScourCapacity only from the soil below the scour depthA large shaft is likely better than a group of piles
Coarse gravelPrecast concrete where hard driving is expected; no H-piles or open-end pipeLikely the better option

How a deep foundation is designed

A deep foundation is checked for its geotechnical capacity and for the strength of its own section. The geotechnical side covers the shaft and toe resistance of a single element, the capacity of the group as its piles and as a block, settlement, lateral load, uplift and, where a soft stratum settles around the piles, the drag load of negative skin friction.

In allowable stress design the ultimate capacity is divided by a factor of safety. FHWA notes that static methods have mostly recommended 3, and it ties the factor to how the piles are controlled on site: from 2.00 with a static load test and wave equation analysis to 3.50 with the Gates dynamic formula (Table 9-5). AASHTO LRFD replaces it with resistance factors for each method. The pile guide shows the alpha and beta methods, the group and the load tests in detail.

Design deep foundations in Rischio

Rischio’s pile foundation tool designs single piles and rectangular groups, driven (precast concrete, closed-end steel pipe, timber, steel H) or bored, through layered clays and sands with rock below and the water table at any depth. It calculates the shaft resistance stratum by stratum and the toe resistance by the methods AASHTO gives for each type, the group as its piles and, with the toe in clay, as one block, the settlement, lateral load on p–y curves, downdrag and scour, and the section of a steel pile or a drilled shaft by AASHTO LRFD. Every result shows its equation with your numbers.

Below is the studio’s editor with a group of driven piles. Change the length, the diameter or the strata and calculate.

For one pile or a group without an account, the free pile capacity calculator uses the same engine: Tomlinson’s α in clay and Nordlund’s method in sand for a driven pile, AASHTO’s α and β methods for a bored one, and block failure for a group with its toe in clay. The docs explain shaft resistance, toe resistance and pile groups.

Frequently asked questions

What are the types of deep foundation?

Driven piles (concrete, steel or timber), drilled shafts (also called bored piles, drilled piers or caissons), micropiles, continuous flight auger piles and, for some bridge piers in deep water, sunk caissons.

When is a deep foundation required?

When the soil near the surface is too weak or compressible for the load; when the foundation must resist uplift, lateral load or overturning; when scour, liquefaction or expansive and collapsible soils make shallow bearing unreliable; and when excavation next to the structure is planned.

What is the difference between a pile and a drilled shaft?

A pile is a slender element driven, drilled or otherwise installed. In common use the word means a driven pile, made before it goes into the ground. A drilled shaft is cast in place in a drilled hole and is usually larger in diameter. Both carry load by shaft and toe resistance.

Is a caisson a deep foundation?

Yes. In the United States the word is often used for a drilled shaft. Strictly, a caisson is a very large hollow structure sunk into place by excavating inside or under it, used for bridge piers in water.

How deep is a deep foundation?

There’s no fixed depth. A deep foundation is embedded far deeper than its width, and its length is set by the depth of the stratum that carries the load or by the shaft length needed to develop enough resistance.

References

  • AASHTO (2024). AASHTO LRFD Bridge Design Specifications, 10th edition. American Association of State Highway and Transportation Officials. Article 10.2 (definitions), 10.7 (driven piles), 10.8 (drilled shafts) and 10.9 (micropiles).
  • Samtani, N.C. and Nowatzki, E.A. (2006). Soils and Foundations Reference Manual, Volume II, FHWA-NHI-06-089. Federal Highway Administration. Chapter 9, deep foundations. https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06089.pdf
  • Brown, D.A., Turner, J.P. and Castelli, R.J. (2010). Drilled Shafts: Construction Procedures and LRFD Design Methods, FHWA-NHI-10-016 (GEC 10). Federal Highway Administration.
  • Sabatini, P.J., Tanyu, B., Armour, T., Groneck, P. and Keeley, J. (2005). Micropile Design and Construction, FHWA-NHI-05-039. Federal Highway Administration.
  • Brown, D.A., Dapp, S.D., Thompson, W.R. and Lazarte, C.A. (2007). Design and Construction of Continuous Flight Auger (CFA) Piles, GEC 8, FHWA-HIF-07-03. Federal Highway Administration.
  • Hannigan, P.J., Rausche, F., Likins, G.E., Robinson, B.R. and Becker, M.L. (2016). Design and Construction of Driven Pile Foundations, Volume I, FHWA-NHI-16-009 (GEC 12). Federal Highway Administration.
  • Das, B.M. and Sivakugan, N. (2019). Principles of Foundation Engineering, 9th edition, SI. Cengage. Section 13.1 (drilled shafts).