Rischio
Start free

Shallow Foundation: Definition, Types and Design

What a shallow foundation is, the types of shallow foundation (isolated, strip, combined and strap footings, and mats) and how one is designed.

9 min readLéelo en español
299.6 kPaBearing capacityFS 4.44 ≥ 3.0133.3 kPaBearing capacityFS 4.14 ≥ 3.0
In this article
  1. What makes a foundation shallow
  2. Types of shallow foundation
  3. When a shallow foundation works
  4. How a shallow foundation is designed
  5. Design a shallow foundation in Rischio
  6. Frequently asked questions
  7. References

A shallow foundation carries the load of a structure to the soil or rock just below it. AASHTO LRFD defines it as “a foundation that derives its support by transferring load directly to the soil or rock at shallow depth” (Article 10.2). Footings and mats are shallow foundations. Piles, drilled shafts and micropiles, which take the load down through weak ground to firmer strata, are deep foundations.

Where the ground near the surface is strong enough and settles little under the load, a shallow foundation is the usual answer. This guide covers how shallow is defined, the types of shallow foundation and what each one carries, and the checks that size one.

What makes a foundation shallow

The ratio of its depth to its width. Terzaghi called a foundation shallow when its depth DfD_f is no greater than its width BB:

DfB≤1\frac{D_f}{B} \le 1

Later authors have also counted foundations with DfD_f up to 3 or 4 times BB as shallow (Das and Sivakugan, Section 6.3). FHWA’s Soils and Foundations manual describes the difference more loosely: a shallow foundation’s depth is small compared with its width or length, while a driven pile or a drilled shaft is embedded far deeper than its diameter. The manual also warns that the exact boundary matters less than what each design method assumes. A bearing capacity equation derived for a footing near the surface isn’t meant for a pile.

Types of shallow foundation

Shallow foundations differ by how many columns or walls each one carries and how much of the plan it covers.

IsolatedStripproperty lineCombinedproperty lineStrapMat
The types of shallow foundation in plan: concrete in light grey, columns and the wall in dark grey.
TypeWhat it carriesWhere it’s used
Isolated footing (spread or pad footing)One columnColumns well apart, on soil that is competent near the surface
Strip footing (continuous or wall footing)A load-bearing wall or a row of columnsWalls of buildings; FHWA treats a footing with L/B≥10L/B \ge 10 as a strip
Combined footingTwo or more columns on one slabFootings that would overlap, uneven column spacing, a column at a property line
Strap footingTwo footings joined by a stiff beamAn exterior column at a property line with the next column far away
Mat or raft foundationEvery column and wall, or most of themFootings that would cover more than about half the plan, weak or variable soil
Wall and abutment footingsA retaining wall’s stem or a bridge abutmentWalls and abutments on competent soil, with lateral load and moment

Isolated footing

An isolated footing spreads the load of a single column over enough soil to keep it from failing in shear. FHWA counts any footing with a length less than 10 times its width as isolated. Its size follows the column’s loads and the strength and compressibility of the soil under it, and it grows when the load is eccentric. Under bridge columns, isolated footings are typically larger than 3 m by 3 m. The structural design checks bending at the face of the column and shear, including punching shear around it. Isolated, spread and combined footings works through the design of one with a moment, step by step.

Strip footing

FHWA calls the continuous strip footing the most common foundation for buildings. It runs under a bearing wall or a single row of columns and is designed per metre of length, in plane strain. Because it is long, the stress it adds reaches deeper: FHWA gives a depth of significant influence of 2 to 4 times the width for an isolated footing and at least 4 times the width for a strip. Its structural design is usually governed by beam shear and bending across the width.

Combined footing

A combined footing carries two or more columns on one rectangular or trapezoidal slab. FHWA lists two reasons to use one: column spacing that isn’t uniform, and isolated footings so close together that one slab is simpler to form and build. The third common case is a column on a property line, where a footing centred on it would cross into the next lot. The slab is placed so that its centroid falls under the resultant of the column loads.

Strap footing

A strap footing joins the footing of an exterior column to an interior one with a beam. The exterior footing sits off centre under its column at the property line, and the strap carries the moment of that eccentricity to the interior footing, so both bear with a nearly uniform pressure. Das and Sivakugan group it with the combined footings (Section 10.1).

Mat or raft foundation

A mat, or raft, is a single heavily reinforced slab under the whole structure or a large part of it. FHWA notes that a mat is often economical when spread footings would cover more than about 50 percent of the plan area, and Das and Sivakugan add two more reasons: differential settlement that must stay very small, and soil with weak pockets or conditions that change across the site. The slab bridges local soft spots and reduces the differential movement between columns. Its total settlement can be larger, because a wide slab loads the soil to a greater depth. Raft foundation covers its types and design.

Wall and abutment footings

The base of a cantilever retaining wall is a spread footing. It resists the overturning moment and the eccentric vertical load that the earth pressure behind the stem puts on it, and it has to hold against sliding. Bridge abutments on spread footings do the same while also carrying the superstructure. Step-by-step retaining wall design checks such a footing, and Rischio’s retaining wall tool runs those checks.

When a shallow foundation works

FHWA defines the allowable bearing capacity of a spread footing as the lesser of two pressures:

  • the pressure that causes a shear failure of the soil, divided by a factor of safety;
  • the pressure that causes a specified settlement.

The manual adds that experience shows settlement usually decides whether a spread footing can be used. A narrow footing is limited by shear. As the footing gets wider, the stress it adds reaches deeper soil, and settlement takes over: on compressible ground, a wider footing has to be designed for a lower pressure. On soft clay a footing can grow past any practical size this way, and the load then goes down to a deep foundation. Shallow vs deep foundations sets out that decision with a worked example.

A shallow foundation also has to sit below the depth where the ground freezes and, for a bridge, below the depth the stream can scour. Where those depths are large, or the soil near the surface is soft, expansive or liquefiable, FHWA’s list of situations that call for a deep foundation applies.

How a shallow foundation is designed

The geotechnical design of a spread footing has two parts, in FHWA’s words: first an allowable bearing capacity that keeps the foundation stable at a reasonable size, then the settlement under the actual loads and when it happens. FHWA’s design flow for a bridge footing (Figure 8-11 of its manual) runs these steps:

  1. Lay out the bridge, review the existing geologic and subsurface data, and visit the site.
  2. Set the footing’s depth for scour and frost.
  3. Determine the loads on the footing.
  4. Explore the subsurface and test the soil in the laboratory. How to read a geotechnical report covers what comes back.
  5. Calculate the allowable bearing capacity from shear and from settlement.
  6. Calculate the sliding resistance and the passive resistance in front of the footing.
  7. Check overall (global) stability, with service loads.
  8. Size the footing with service loads, then check it for overturning and sliding.
  9. Design the concrete with factored loads.

Bearing capacity

Terzaghi’s equation gives the ultimate bearing capacity quq_u of a strip footing from the soil’s cohesion c′c', the overburden at the base q=γDfq = \gamma D_f, the unit weight γ\gamma and the width BB:

qu=c′Nc+qNq+12γBNγq_u = c' N_c + q N_q + \tfrac{1}{2} \gamma B N_\gamma

For a square footing it becomes qu=1.3c′Nc+qNq+0.4γBNγq_u = 1.3 c' N_c + q N_q + 0.4 \gamma B N_\gamma. The bearing capacity factors NcN_c, NqN_q and NγN_\gamma depend on the friction angle. The general bearing capacity equation adds shape, depth and inclination factors to each term. FHWA recommends a minimum factor of safety of 3.0 against bearing failure for most bridge foundations. Bearing capacity of soil works through both equations, the water table and eccentric loads.

Settlement

The settlement of a footing has an immediate part, which dominates in sand, and the consolidation of any clay under it, which develops over time. Terzaghi and Peck suggested 25 mm as the limit for isolated footings and 50 mm for rafts (Das and Sivakugan, Section 9.16), and the differential settlement between neighbouring footings matters as much as the total. Foundation settlement covers both kinds.

Eccentricity and sliding

A moment or a horizontal load moves the resultant off the centre of the base. While it stays within the middle third (e≤B/6e \le B/6), the whole base presses on the soil. A horizontal load must also be resisted by friction or adhesion on the base, with a factor of safety, usually 1.5. The isolated footing guide shows both checks with numbers.

Design a shallow foundation in Rischio

Rischio’s footing tool checks square, rectangular, strip and circular footings under vertical and horizontal loads and moments in both directions, on layered soil with the water table at any depth. It works out the bearing capacity by the general equation, the eccentricity, sliding, the elastic settlement and the consolidation of each clay, against your factors of safety or by AASHTO LRFD, and shows every equation with your numbers. It checks the ground under the footing; the concrete’s punching shear and reinforcement are outside it.

Below is the studio’s editor with an isolated footing. Change its size, its load or the soil and calculate.

For a single footing’s bearing capacity without an account, the free bearing capacity calculator uses the same engine. How it calculates is in the docs: bearing capacity and settlement.

Frequently asked questions

What are the types of shallow foundation?

Isolated (spread or pad) footings under single columns, strip footings under walls or rows of columns, combined footings under two or more columns, strap footings joined by a beam, and mat or raft foundations under the whole structure. The footings of retaining walls and bridge abutments are spread footings too.

What is the depth of a shallow foundation?

By Terzaghi’s definition, no more than its width; some authors accept up to 3 or 4 times the width. The founding depth itself comes from the geotechnical report: below topsoil and uncontrolled fill, below the frost depth, and below the scour depth where a stream can reach it.

What is the difference between a shallow and a deep foundation?

A shallow foundation transfers its load directly to the soil just under its base. A deep foundation carries it through weak layers to soil or rock deeper down, by bearing at its toe, friction along its shaft, or both. Shallow vs deep foundations compares the two in detail.

Is a raft foundation a shallow foundation?

Yes. A raft bears on the soil right under it, like a footing, and is checked with the same bearing capacity and settlement methods. It joins all the columns into one slab.

What factor of safety is used for a shallow foundation?

FHWA recommends at least 3.0 against bearing failure for most bridge foundations, and 3 is the usual value in allowable stress design. Sliding is commonly held to 1.5. Under AASHTO LRFD, load and resistance factors take the place of a single factor of safety.

References

  • AASHTO (2024). AASHTO LRFD Bridge Design Specifications, 10th edition. American Association of State Highway and Transportation Officials. Article 10.2 (definitions) and Article 10.6 (spread footings).
  • Samtani, N.C. and Nowatzki, E.A. (2006). Soils and Foundations Reference Manual, Volume II, FHWA-NHI-06-089. Federal Highway Administration. Chapter 8, shallow foundations. https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06089.pdf
  • Das, B.M. and Sivakugan, N. (2019). Principles of Foundation Engineering, 9th edition, SI. Cengage. Sections 6.3 (Terzaghi’s bearing capacity theory), 9.16 (tolerable settlement) and 10.1 (combined footings and mats).