Rischio
Start free

Bearing Capacity of Soil: Equations, Values and Examples

How to calculate the bearing capacity of soil: Terzaghi's and the general equation, the water table, eccentric loads, typical values and a worked example.

18 min readLéelo en español
50.7 kPa50.7 kPaBearing capacityFS 21.31 ≥ 3.0
In this article
  1. Ultimate, allowable and net bearing capacity
  2. How soil fails under a footing
  3. Terzaghi’s bearing capacity equation
  4. The general bearing capacity equation
  5. How the water table changes the bearing capacity
  6. Eccentric and inclined loads
  7. Worked example: a square footing over the water table
  8. Settlement often governs before bearing capacity
  9. How the bearing capacity is found on a real project
  10. Typical values: the IBC’s presumptive load-bearing values
  11. Which soils have the best bearing capacity
  12. Frequently asked questions

The bearing capacity of soil is the largest pressure a foundation can put on the ground before the soil under it fails in shear. Its ultimate value, quq_u, is calculated from the soil’s strength (c′c' and ϕ′\phi'), its unit weight and the footing’s width and depth, with Terzaghi’s equation or the general bearing capacity equation. Divided by a factor of safety, usually 3, it gives the allowable bearing capacity that footings are sized with. Settlement then decides how much of that pressure a design can use.

Every equation below is applied to one footing: a 2.00 m square base, 1.50 m deep in silty sand, with the water table 0.50 m under it. The worked example solves it by hand and compares the result with Rischio’s engine and with Terzaghi’s equation.

Ultimate, allowable and net bearing capacity

  • The ultimate bearing capacity, quq_u, is the average pressure under the base at which the soil fails in shear.
  • The allowable bearing capacity is qall=qu/FSq_{all} = q_u/FS. For foundations the factor of safety FSFS is usually 3: it covers the uncertainty in the soil’s strength and keeps the footing far from the large movements that come before failure.
  • The net bearing capacity, qu−qq_u - q, takes off the effective overburden at the base, qq (γDf\gamma D_f in dry soil), which the ground already carried before the excavation. The net allowable bearing capacity is (qu−q)/FS(q_u - q)/FS.

A geotechnical report can give its allowable pressure on either basis, and checking a footing against the wrong one is a common mistake; gross and net bearing pressure works through a check on each. Rischio compares gross values: quq_u against the largest pressure the load puts under the base, qmaxq_{max}, and asks for FS=qu/qmax≥3FS = q_u/q_{max} \ge 3. Its vertical load VV is everything that reaches the soil at the base, so it should include the footing’s own weight and the backfill over it.

How soil fails under a footing

Vesić described three ways the ground gives way under a footing. Which one happens depends on how dense or stiff the soil is and on how deep the footing sits:

  • General shear failure is typical of dense sand and stiff clay. A continuous slip surface runs from under the footing up to the ground surface, the soil beside the footing heaves, and the load reaches a clear peak before the footing sinks and tilts.
  • Local shear failure shows up in medium-dense sand and firm clay. The slip surfaces form under the footing without clearly reaching the surface, and the load keeps rising with large settlement, with no clear peak.
  • Punching shear failure belongs to loose sand and soft clay, and to deep footings. The footing pushes straight down, shearing the soil along its edges, and the ground around it doesn’t heave.

The bearing capacity equations describe general shear. For local shear, Terzaghi reduced the soil’s strength to two thirds before applying them, cˉ′=23c′\bar{c}' = \tfrac{2}{3}c' and tan⁡ϕˉ′=23tan⁡ϕ′\tan\bar{\phi}' = \tfrac{2}{3}\tan\phi', so a ϕ′\phi' of 30° becomes 21.1°. In soil loose or soft enough to punch, settlement usually limits the footing long before its bearing capacity does.

q = γ Dfq = γ Dfqu · BIIIIIIIIIII60°30°I · active wedgeII · radial shearIII · passive zone
General shear under a strip footing 2.00 m wide and 1.50 m deep in the example's silty sand, φ' = 30°: the wedge's sides at 45° + φ'/2 = 60°, the passive zones' at 45° − φ'/2 = 30°.

Under a strip footing, general shear forms three zones on each side. Zone I is a wedge under the base that moves down with the footing as if it were part of it. Zones II shear radially and are bounded below by a logarithmic spiral. Zones III are passive Rankine zones, pushed up and out by zones II. In Prandtl’s solution, where the NcN_c and NqN_q factors below come from, the wedge’s sides rise at 45°+ϕ′/245° + \phi'/2 and the passive zones’ lower sides at 45°−ϕ′/245° - \phi'/2. For ϕ′=30°\phi' = 30° the mechanism reaches about 1.6B1.6B under the base and spreads 4.8B4.8B to each side of the centre. The soil above the base doesn’t shear in this model: all it contributes is its weight, the overburden q=γDfq = \gamma D_f at the level of the base.

Terzaghi’s bearing capacity equation

Terzaghi (1943) wrote the first complete bearing capacity equation, for a strip footing under a vertical, centred load failing in general shear:

qu=c′Nc+qNq+12γBNγq_u = c' N_c + q N_q + \tfrac{1}{2} \gamma B N_\gamma

Each term is one source of resistance: the cohesion c′c' along the slip surfaces, the overburden qq that the passive zones have to lift, and the weight of the soil inside the failure zone, with γ\gamma the unit weight under the base and BB the footing’s width. For square and circular footings he raised the cohesion term and lowered the weight term:

qu=1.3 c′Nc+qNq+0.4 γBNγ(square)q_u = 1.3\,c' N_c + q N_q + 0.4\,\gamma B N_\gamma \quad \text{(square)} qu=1.3 c′Nc+qNq+0.3 γBNγ(circular, B its diameter)q_u = 1.3\,c' N_c + q N_q + 0.3\,\gamma B N_\gamma \quad \text{(circular, } B \text{ its diameter)}

His factors NqN_q and NcN_c have a closed form:

Nq=e2(3π/4−ϕ′/2)tan⁡ϕ′2cos⁡2(45∘+ϕ′/2),Nc=Nq−1tan⁡ϕ′N_q = \frac{e^{2(3\pi/4 - \phi'/2)\tan\phi'}}{2\cos^2(45^\circ + \phi'/2)}, \qquad N_c = \frac{N_q - 1}{\tan\phi'}

NγN_\gamma is read from tables, which differ a little. With ϕ′=0\phi' = 0, Nc=5.7N_c = 5.7, Nq=1N_q = 1 and Nγ=0N_\gamma = 0; with ϕ′=30°\phi' = 30°, Nc=37.16N_c = 37.16, Nq=22.46N_q = 22.46 and the tables give NγN_\gamma between 19 and 20.

Terzaghi’s equation is still the quickest hand check. It has no depth factor, so the soil above the base counts only as weight, and no inclination factor, so it doesn’t cover a footing pushed sideways. For the embedded footing of the example it gives 26% less than the general equation.

The general bearing capacity equation

Meyerhof (1963) extended Terzaghi’s three terms with factors for the footing’s shape, its depth and the inclination of the load. This general equation is the one Rischio’s engine applies, in the studio and in the free bearing capacity calculator:

qu=c′NcFcsFcdFci+qNqFqsFqdFqi+12γ′B′NγFγsFγdFγiq_u = c' N_c F_{cs} F_{cd} F_{ci} + q N_q F_{qs} F_{qd} F_{qi} + \tfrac{1}{2} \gamma' B' N_\gamma F_{\gamma s} F_{\gamma d} F_{\gamma i}

The bearing capacity factors are Reissner’s, Prandtl’s and Vesić’s:

Nq=tan⁡2(45∘+ϕ′2)eπtan⁡ϕ′,Nc=Nq−1tan⁡ϕ′,Nγ=2 (Nq+1)tan⁡ϕ′N_q = \tan^2\left(45^\circ + \frac{\phi'}{2}\right) e^{\pi \tan\phi'}, \qquad N_c = \frac{N_q - 1}{\tan\phi'}, \qquad N_\gamma = 2\,(N_q + 1)\tan\phi'
ϕ′\phi'NcN_cNqN_qNγN_\gamma
0°5.141.000.00
5°6.491.570.45
10°8.342.471.22
15°10.983.942.65
20°14.836.405.39
25°20.7210.6610.88
30°30.1418.4022.40
35°46.1233.3048.03
40°75.3164.20109.41

De Beer’s shape factors use the effective dimensions B′B' and L′L', and are all 1 for a strip:

Fcs=1+B′L′ NqNc,Fqs=1+B′L′tan⁡ϕ′,Fγs=1−0.4 B′L′F_{cs} = 1 + \frac{B'}{L'}\,\frac{N_q}{N_c}, \qquad F_{qs} = 1 + \frac{B'}{L'}\tan\phi', \qquad F_{\gamma s} = 1 - 0.4\,\frac{B'}{L'}

Hansen’s depth factors use the full width BB, for Df/B≤1D_f/B \le 1:

Fqd=1+2tan⁡ϕ′ (1−sin⁡ϕ′)2 DfB,Fcd=Fqd−1−FqdNctan⁡ϕ′,Fγd=1F_{qd} = 1 + 2\tan\phi'\,(1 - \sin\phi')^2\,\frac{D_f}{B}, \qquad F_{cd} = F_{qd} - \frac{1 - F_{qd}}{N_c \tan\phi'}, \qquad F_{\gamma d} = 1

For a deeper base, tan⁡−1(Df/B)\tan^{-1}(D_f/B), in radians, takes the place of Df/BD_f/B. The inclination factors, Meyerhof’s and Hanna and Meyerhof’s, depend on the inclination of the load, β=tan⁡−1(H/V)\beta = \tan^{-1}(H/V), and FγiF_{\gamma i} drops to 0 once β≥ϕ′\beta \ge \phi':

Fci=Fqi=(1−β90∘)2,Fγi=(1−βϕ′)2F_{ci} = F_{qi} = \left(1 - \frac{\beta}{90^\circ}\right)^2, \qquad F_{\gamma i} = \left(1 - \frac{\beta}{\phi'}\right)^2

With ϕ′=0\phi' = 0, the undrained case of a saturated clay loaded faster than it can drain, the strength is the undrained shear strength sus_u, Nc=5.14N_c = 5.14, Nq=1N_q = 1, Nγ=0N_\gamma = 0 and Fcd=1+0.4 Df/BF_{cd} = 1 + 0.4\,D_f/B, so qu=5.14 suFcsFcd+qq_u = 5.14\,s_u F_{cs} F_{cd} + q. For a footing on clay, the end of construction is usually the critical moment: the clay gains strength as it drains afterwards.

The strength parameters c′c' and ϕ′\phi' are those of the stratum the base rests on, so a weaker layer within the failure zone, which reaches about 1.6B1.6B under the base for ϕ′=30°\phi' = 30°, makes the result unsafe and calls for a layered analysis. The overburden qq and the unit weight γ′\gamma' are effective values, which is where the water table comes in. The bearing capacity theory in the docs has every factor with its conditions.

How the water table changes the bearing capacity

Terzaghi’s principle of effective stress, σ′=σ−u\sigma' = \sigma - u, says that the soil’s strength depends on the stress its grains carry, the total stress less the pore water pressure. Below the water table each metre of soil adds γsat−γw\gamma_{sat} - \gamma_w of effective stress instead of γ\gamma, roughly half as much. The equation uses two of these stresses, and where the water table sits decides how much it lowers them:

  • Water above the base, at a depth Dw<DfD_w < D_f: q=γDw+(γsat−γw)(Df−Dw)q = \gamma D_w + (\gamma_{sat} - \gamma_w)(D_f - D_w), and the soil under the base weighs γ′=γsat−γw\gamma' = \gamma_{sat} - \gamma_w.
  • Water within BB under the base: q=γDfq = \gamma D_f, and γ′\gamma' is the average of γ\gamma above the water and γsat−γw\gamma_{sat} - \gamma_w below it over the depth BB under the base, each weighted by its thickness.
  • Water deeper than Df+BD_f + B: no effect.

Rischio’s engine works the same way with any number of strata: qq is the effective vertical stress at the base, and γ′\gamma' the thickness-weighted average between DfD_f and Df+BD_f + B. This is what it gives for the example’s footing with the water table at different depths:

Water table depthqq (kPa)γ′\gamma' (kN/m³)quq_u (kPa)FSFS
Below 3.50 m27.018.001,493.63.98
2.00 m, 0.50 m under the base27.012.141,414.83.77
1.50 m, at the base27.010.191,388.63.70
1.00 m23.110.191,250.73.34
At the ground surface15.310.19974.92.60

From dry to flooded, quq_u drops by 35% and the factor of safety falls from 3.98 to 2.60. The level to design for is the highest the water can reach during the structure’s life, often above the one measured while drilling.

Eccentric and inclined loads

A moment MM moves the resultant of the load off centre by e=M/Ve = M/V. Meyerhof’s approach keeps only the part of the base centred on the load: the effective width is B′=B−2eB' = B - 2e, and L′=L−2eLL' = L - 2e_L when the load is also off centre along the length. The general equation uses B′B' in its third term and B′/L′B'/L' in the shape factors, while the depth factors keep the full BB.

The pressure under the base stays linear over the whole footing, from qminq_{min} to qmax=VBL(1±6eB)q_{max} = \frac{V}{BL}\left(1 \pm \frac{6e}{B}\right). While e≤B/6e \le B/6, inside the middle third, the whole base presses on the soil; past it, qminq_{min} turns negative and an edge lifts off. Rischio checks quq_u, worked out on B′B', against qmaxq_{max}.

Put a moment M=150M = 150 kN·m along the width of the example’s footing: e=150/1,500=0.10e = 150/1{,}500 = 0.10 m and B′=1.80B' = 1.80 m, so quq_u drops to 1,362.1 kPa while qmaxq_{max} rises to 375.0×1.3=487.5375.0 \times 1.3 = 487.5 kPa (qmin=262.5q_{min} = 262.5 kPa). The factor of safety falls from 3.77 to 2.79, a quarter less and below 3, for a load moved 10 cm.

A horizontal load HH inclines the resultant by β=tan⁡−1(H/V)\beta = \tan^{-1}(H/V). With HH a tenth of VV, β=5.7°\beta = 5.7°, and for ϕ′=30°\phi' = 30° the inclination factors are Fci=Fqi=0.88F_{ci} = F_{qi} = 0.88 and Fγi=0.66F_{\gamma i} = 0.66.

Worked example: a square footing over the water table

A column brings 1,500 kN to the base of a square footing 2.00 m wide, founded 1.50 m deep in a silty sand. The water table is 2.00 m deep, 0.50 m under the base. Take γw=9.81\gamma_w = 9.81 kN/m³.

DataValue
FootingB=L=2.00B = L = 2.00 m, Df=1.50D_f = 1.50 m
Load at the baseV=1,500V = 1{,}500 kN, vertical and centred
Silty sandγ=18\gamma = 18 kN/m³, γsat=20\gamma_{sat} = 20 kN/m³, c′=5c' = 5 kPa, ϕ′=30°\phi' = 30°
Water table2.00 m deep
V = 1,500 kNγ = 18γsat − γw= 10.19γ' = 12.14 kN/m³q = 27.0 kPaWater tableSilty sandγ = 18 kN/m³γsat = 20 kN/m³c' = 5 kPaφ' = 30°Df = 1.50 m2.00 m0.50 m1.50 mB = L = 2.00 m
The example's footing. Over the 2.00 m under the base, 0.50 m of soil weighs γ = 18 kN/m³ and 1.50 m weighs γsat − γw = 10.19 kN/m³: γ' = 12.14 kN/m³.

Step 1: bearing capacity factors

Nq=tan⁡260∘ eπtan⁡30∘=3×6.134=18.40N_q = \tan^2 60^\circ \, e^{\pi \tan 30^\circ} = 3 \times 6.134 = 18.40 Nc=18.40−1tan⁡30∘=30.14,Nγ=2 (18.40+1)tan⁡30∘=22.40N_c = \frac{18.40 - 1}{\tan 30^\circ} = 30.14, \qquad N_\gamma = 2\,(18.40 + 1)\tan 30^\circ = 22.40

Step 2: overburden and unit weight under the base

The water table is under the base, so the overburden is that of the dry soil, q=γDf=18×1.50=27.0q = \gamma D_f = 18 \times 1.50 = 27.0 kPa. The 2.00 m under the base, from 1.50 to 3.50 m deep, hold 0.50 m above the water table and 1.50 m below it, where the soil weighs 20−9.81=10.1920 - 9.81 = 10.19 kN/m³:

γ′=0.50×18+1.50×10.192.00=12.14 kN/m3\gamma' = \frac{0.50 \times 18 + 1.50 \times 10.19}{2.00} = 12.14 \text{ kN/m}^3

Step 3: shape, depth and inclination factors

The load is centred, so B′=L′=2.00B' = L' = 2.00 m and B′/L′=1B'/L' = 1:

Fcs=1+18.4030.14=1.611,Fqs=1+tan⁡30∘=1.577,Fγs=1−0.4=0.60F_{cs} = 1 + \frac{18.40}{30.14} = 1.611, \qquad F_{qs} = 1 + \tan 30^\circ = 1.577, \qquad F_{\gamma s} = 1 - 0.4 = 0.60

With Df/B=1.50/2.00=0.75D_f/B = 1.50/2.00 = 0.75:

Fqd=1+2tan⁡30∘(1−sin⁡30∘)2×0.75=1.217,Fcd=1.217−1−1.21730.14tan⁡30∘=1.229,Fγd=1F_{qd} = 1 + 2 \tan 30^\circ (1 - \sin 30^\circ)^2 \times 0.75 = 1.217, \qquad F_{cd} = 1.217 - \frac{1 - 1.217}{30.14 \tan 30^\circ} = 1.229, \qquad F_{\gamma d} = 1

The load is vertical, so the three inclination factors are 1.

Step 4: ultimate bearing capacity

Term by term, carrying every decimal:

c′NcFcsFcd=5×30.14×1.611×1.229=298.3 kPaqNqFqsFqd=27.0×18.40×1.577×1.217=953.3 kPa12γ′B′NγFγsFγd=0.5×12.14×2.00×22.40×0.60=163.2 kPaqu=298.3+953.3+163.2=1,414.8 kPa\begin{aligned} c' N_c F_{cs} F_{cd} &= 5 \times 30.14 \times 1.611 \times 1.229 = 298.3 \text{ kPa} \\ q N_q F_{qs} F_{qd} &= 27.0 \times 18.40 \times 1.577 \times 1.217 = 953.3 \text{ kPa} \\ \tfrac{1}{2} \gamma' B' N_\gamma F_{\gamma s} F_{\gamma d} &= 0.5 \times 12.14 \times 2.00 \times 22.40 \times 0.60 = 163.2 \text{ kPa} \\ q_u &= 298.3 + 953.3 + 163.2 = 1{,}414.8 \text{ kPa} \end{aligned}

Step 5: allowable bearing capacity and factor of safety

qall=1,414.83=471.6 kPa,qmax=VBL=1,5002.00×2.00=375.0 kPaq_{all} = \frac{1{,}414.8}{3} = 471.6 \text{ kPa}, \qquad q_{max} = \frac{V}{BL} = \frac{1{,}500}{2.00 \times 2.00} = 375.0 \text{ kPa} FS=quqmax=1,414.8375.0=3.77≥3FS = \frac{q_u}{q_{max}} = \frac{1{,}414.8}{375.0} = 3.77 \ge 3

The footing passes, with an allowable bearing capacity of 471.6 kPa (about 9,850 psf). Rischio’s engine gives the same: qu=1,414.8q_u = 1{,}414.8 kPa and FS=3.77FS = 3.77, with q=27.0q = 27.0 kPa, γ′=12.14\gamma' = 12.14 kN/m³ and every factor above in its calculation report.

Terzaghi’s value beside it

Terzaghi’s equation for a square footing, with his factors at 30° and the same qq and γ′\gamma', gives a lower value. Its Nγ=20.12N_\gamma = 20.12 comes from the closed-form fit to his tabulated values that the calculator uses:

qu=1.3×5×37.16+27.0×22.46+0.4×12.14×2.00×20.12=241.6+606.3+195.4=1,043.3 kPa\begin{aligned} q_u &= 1.3 \times 5 \times 37.16 + 27.0 \times 22.46 + 0.4 \times 12.14 \times 2.00 \times 20.12 \\ &= 241.6 + 606.3 + 195.4 = 1{,}043.3 \text{ kPa} \end{aligned}

That is 26% less than the general equation, and a factor of safety of 1,043.3/375.0=2.781{,}043.3/375.0 = 2.78, so by Terzaghi alone the footing would have to grow. Most of the gap is the overburden term, 606.3 against 953.3 kPa. Terzaghi’s equation has no depth factor and no shape factor on that term, while the general equation credits the 1.50 m of soil over the base with shear resistance (Fqd=1.217F_{qd} = 1.217) and raises the term for a square base (Fqs=1.577F_{qs} = 1.577).

The calculator below opens on this same footing without the water. Switch the water table on, at 2 m, and it gives the quq_u, the factor of safety and Terzaghi’s value worked out above.

Calculator · Rischio's engine · general bearing capacity equation

Footing
Geometry
m
m
Load
kN
kN
kN·m
Soil
kN/m³
kPa
°
Water
Water table

These data give no result: check the values.

Rischio's engine calculated this. In the studio you keep the model, change it on the drawing and get the calculation report, every step shown.

Start free

This calculator is offered for information and technical support. It doesn't replace professional judgment or the reviews due, and its use is the user's responsibility.

To keep the model, try other strata and loads or get a calculation report with every step, build the footing in Rischio’s footing tool.

Settlement often governs before bearing capacity

Give the example’s silty sand an elastic modulus of 15 MPa and a Poisson’s ratio of 0.3, and Rischio’s footing tool estimates an elastic settlement of 32.3 mm at the centre of the base, more than the 25 mm it allows by default. The footing that carries its load with FS=3.77FS = 3.77 fails on settlement. A 3.00 m square footing brings the settlement down to 23.9 mm, with a factor of safety of 8.45 on bearing. On sand, and under wide footings, settlement often governs like this.

The two checks change differently with the footing’s size. Under the same pressure, a wider footing has more bearing capacity, through the 12γ′B′Nγ\tfrac{1}{2}\gamma' B' N_\gamma term, and also settles more, because the elastic settlement grows in proportion to the width. Past a certain width, settlement sets the allowable pressure.

In clays the settlement that matters is usually consolidation, which is slow and often larger than the elastic part. Rischio’s elastic estimate leaves it out, and a warning says so with every settlement result. How foundation settlement is calculated covers both, and the settlement theory in the docs has the method the footing tool uses.

How the bearing capacity is found on a real project

Every number in the equations comes from the geotechnical investigation: borings, field tests and laboratory tests on the samples, with the water level read in the boreholes. How to read a geotechnical report follows that chain from a boring log to an allowable pressure.

Laboratory strength tests

The direct shear test (ASTM D3080) gives the drained strength parameters c′c' and ϕ′\phi', mostly of sands, and the consolidated-undrained triaxial test with pore pressure readings (ASTM D4767) gives them for clays. The unconsolidated-undrained triaxial test (ASTM D2850) and the unconfined compression test (ASTM D2166) give the undrained strength sus_u for the short-term case. The Academy’s direct shear lesson and the direct shear calculator go from a test’s readings to c′c' and ϕ′\phi'.

SPT and CPT correlations

The standard penetration test (ASTM D1586) counts the hammer blows that drive a split-spoon sampler 300 mm into the soil, after the first 150 mm of seating. Corrected to 60% of the hammer’s energy, the blow count N60N_{60} correlates with ϕ′\phi' in sands, and Meyerhof’s correlations turn it straight into the allowable pressure for 25 mm of settlement. The cone penetration test (ASTM D5778) gives a continuous profile of cone resistance, which correlates with ϕ′\phi' in sands and gives the undrained strength of clays as su=(qt−σv0)/Nkts_u = (q_t - \sigma_{v0})/N_{kt}, with NktN_{kt} usually between 10 and 20.

Plate load tests

A rigid steel plate, typically 0.3 to 0.76 m across, is loaded in steps at the level of the future base while its settlement is measured. In clay, the footing’s ultimate bearing capacity is taken as the plate’s; in sand, it grows in proportion to the width. The plate only stresses the soil to a depth of about twice its width, so a soft layer at the depth a real footing reaches goes unseen.

Typical values: the IBC’s presumptive load-bearing values

Without a geotechnical study, the International Building Code allows the presumptive load-bearing values of its Table 1806.2, allowable pressures by class of material:

Class of materialpsfkPa
Crystalline bedrock12,000575
Sedimentary and foliated rock4,000192
Sandy gravel and gravel (GW, GP)3,000144
Sand, silty sand, clayey sand, silty gravel and clayey gravel (SW, SP, SM, SC, GM, GC)2,00096
Clay, sandy clay, silty clay, clayey silt, silt and sandy silt (CL, ML, MH, CH)1,50072

Higher values need data to back them, and mud, organic silt, organic clay, peat and unprepared fill get no presumptive value at all. The soil classes use the symbols of the Unified Soil Classification System; the USCS classification calculator puts a soil in its group from its gradation and its Atterberg limits.

These are conservative values for a soil nobody has tested, so use them as an order of magnitude. The example’s silty sand, an SM, would get 2,000 psf (96 kPa), against the 471.6 kPa its calculation allows, and the settlement check still has the last word on that.

Which soils have the best bearing capacity

Rock carries the most, then dense gravel, dense sand and stiff clay. Loose sand, soft clay and silt carry little, and organic soils, peat and uncontrolled fill aren’t fit to found on without treatment. The IBC’s table follows the same order, from 12,000 psf for crystalline bedrock down to 1,500 psf for clays and silts.

The ideal soil for a foundation carries the load on a small footing and settles little and evenly: dense, well-graded sand and gravel or stiff clay, uniform across the site and above the water table. Expansive clays, collapsible soils and loose saturated sands, which can liquefy in an earthquake, need more than a bearing check. When the good stratum lies too deep for a footing, piles take the load down to it, as in pile foundation design; when only the top few metres are poor, ground improvement can treat them in place.

Frequently asked questions

How do you know the bearing capacity of soil?

From a geotechnical investigation. Borings with SPT or CPT soundings and laboratory strength tests give c′c' and ϕ′\phi', or sus_u for clays, and a bearing capacity equation turns them into quq_u; a plate load test measures it at one spot. Where no study is required, the IBC’s presumptive values give a conservative allowable pressure by soil class.

Which soil has the best bearing capacity?

Rock, followed by dense gravel and sand and then stiff clay. In the IBC’s presumptive values, crystalline bedrock takes 12,000 psf (575 kPa), gravel 3,000 psf (144 kPa), sand 2,000 psf (96 kPa), and clay and silt 1,500 psf (72 kPa).

What is a good soil bearing capacity?

There’s no single figure: a soil is good for a foundation when its allowable pressure keeps the footings a practical size and the settlement within limits. As an order of magnitude, the IBC’s presumptive values for soils run from 1,500 psf (72 kPa) for clays and silts to 3,000 psf (144 kPa) for gravels, and a geotechnical study can justify higher values for the actual soil and footing.

Which soil is ideal for a foundation?

Dense, well-graded gravel and sand or stiff clay, uniform across the site and above the water table. Organic soils, peat, uncontrolled fill, expansive clays and loose saturated sands are the ones to avoid or treat.

What units is bearing capacity measured in?

It’s a pressure: kPa (kN/m²) in SI units, psf, ksf or tsf in US units, and kg/cm² or t/m² in much of Latin America. 1 ksf is 47.9 kPa and 1 kg/cm² is 98.1 kPa.

Does the water table reduce bearing capacity?

Yes, once it rises to within a footing’s width under the base. Submerged soil weighs about half as much, which lowers the weight term, and a water table above the base lowers the overburden term too. For the example’s footing, a water table rising from deep down to the ground surface cuts quq_u by 35%.