Inputs
Every field a model of a pile or a pile group takes, as the engine's schema gives it: what it is, its unit and convention, and its limits.
A model is a JSON document, the same one the studio’s forms build, its AI writes and an agent sends with create_model. Every element has an id, stable and unique in the model (the results name by it the elements each check depends on), and a name, shown on the canvas and in the report; strata can also carry a color. Every model states its contract_version, today 15. Units are SI: kN, m, kPa, kN/m³ and degrees.
These are its fields, from the engine’s own schema: what the studio’s forms are built from, and what get_tool_schema gives an agent.
pileone of · required
bored
pile_typetext · required · = "bored"
Bored, cast in place: a round drilled shaft.
sectiongroup · required
shapetext · required · = "circular"
diameternumber · required · > 0
Outside diameter (m).
lengthnumber · required · > 0 · ≤ 300
Length of the pile, from its head to its toe (m).
head_depthnumber · optional · ≥ 0 · default 0
Depth of the pile's head below the ground (m): 0 with the heads at the surface, deeper under a buried cap.
head_fixitytext · optional · one of: free_head, fixed_head · default "free_head"
Under a lateral load: free_head, the head turns; or fixed_head, held by a cap that doesn't let it turn (Das & Sivakugan's restrained head, section 12.19).
yield_momentnumber · optional · > 0
Optional, under a design code: the pile's yield moment M_y (kN·m), from its section and its reinforcement, for a lateral load: with it, the bending check. Refused in free mode, which has no load or resistance factors to design a section by.
pile_modulusnumber · optional · > 0
Optional: modulus of elasticity Ep of the pile (kPa), for a drilled shaft's settlement (AASHTO 10.8.2.2.2), a pile's elastic compression and a lateral load. Empty, AASHTO's for its material: steel 199,947,962 kPa (6.4.1); concrete Ec by Eq. 5.4.2.4-1 from f′c, a drilled shaft's own or 27,579 kPa, a precast pile's 34,474 kPa (5.12.9.4.2); timber 10,342,136 kPa, Southern Pine's and Douglas Fir's (Table 8.4.1.4-1).
concrete_strengthnumber · optional · > 0
Compressive strength f′c of the shaft's concrete (kPa). Required where the shaft enters rock: its side takes the rock's qu no higher than f′c (AASHTO 10.8.3.5.4b), and in a cohesive intermediate geomaterial the fluid concrete's weight by it (AASHTO Table 3.5.1-1); under a design code, with the reinforcement, its structural resistance (AASHTO 10.8.3.9).
reinforcementgroup · optional
Optional, under a design code: a round shaft's reinforcing cage, for its structural resistance in axial compression, axial load and flexure, and shear (AASHTO 10.8.3.9, Section 5); with the concrete's f′c. Refused in free mode, which has no load or resistance factors to design a section by.
bar_countinteger · required · ≥ 1 · ≤ 200
Number of longitudinal bars, equally spaced on one circle; as many as fit it without touching at most.
bar_diameternumber · required · > 0
Diameter of the longitudinal bars (m): a bar of ASTM A615 or A706, #3 to #11, by its nominal diameter.
yield_strengthnumber · optional · > 0 · default 413685.43759
Yield strength fy of the longitudinal bars (kPa): 413,685 by default, ASTM A615 or A706 Grade 60 (AASHTO 5.4.3.1).
covernumber · required · > 0
Clear cover from the shaft's surface to the longitudinal bars (m), the transverse bars within it (AASHTO 5.10.1, cover to the main bars; FHWA GEC 10 recommends 0.0762 m to a shaft up to 0.9144 m wide, 0.1016 m up to 1.524 m and 0.1524 m above, §12.4).
transverse_reinforcementtext · optional · one of: spiral, hoops, ties · default "spiral"
The transverse steel: a spiral, or hoops closed by a weld, a mechanical coupler or hooks (Pn = 0.85 Po), or ties and lap-spliced hoops (0.80 Po) (AASHTO 5.6.4.4).
transverse_bar_diameternumber · required · > 0
Diameter of the spiral's, the hoops' or the ties' bar (m): a bar of ASTM A615 or A706, #3 to #11, by its nominal diameter.
transverse_bar_spacingnumber · required · > 0
The spiral's pitch, or the hoops' or ties' spacing (m).
transverse_yield_strengthnumber · optional · > 0 · default 413685.43759
Yield strength of the transverse bars (kPa): 413,685 by default, Grade 60; in shear, one above that counts up to 517,107 (AASHTO 5.7.2.7).
closed_end_steel_pipe
pile_typetext · required · = "closed_end_steel_pipe"
Driven closed-end steel pipe: a high-displacement pile.
sectiongroup · required
shapetext · required · = "circular"
diameternumber · required · > 0
Outside diameter (m).
lengthnumber · required · > 0 · ≤ 300
Length of the pile, from its head to its toe (m).
head_depthnumber · optional · ≥ 0 · default 0
Depth of the pile's head below the ground (m): 0 with the heads at the surface, deeper under a buried cap.
head_fixitytext · optional · one of: free_head, fixed_head · default "free_head"
Under a lateral load: free_head, the head turns; or fixed_head, held by a cap that doesn't let it turn (Das & Sivakugan's restrained head, section 12.19).
wall_thicknessnumber · optional · > 0
The pipe's wall thickness t (m): its stiffness under a lateral load (Das & Sivakugan, Table 12.2a: 3.17 to 12.7 mm). Required under a lateral load.
yield_strengthnumber · optional · > 0 · default 310000
Yield strength of the steel F_y (kPa): 310 MPa for ASTM A252 Grade 3 (FHWA NHI-16-009, Table 8-1). M_y = F_y S, at first yield (Das & Sivakugan, Eq. 12.116).
pile_modulusnumber · optional · > 0
Optional: modulus of elasticity Ep of the pile (kPa), for a drilled shaft's settlement (AASHTO 10.8.2.2.2), a pile's elastic compression and a lateral load. Empty, AASHTO's for its material: steel 199,947,962 kPa (6.4.1); concrete Ec by Eq. 5.4.2.4-1 from f′c, a drilled shaft's own or 27,579 kPa, a precast pile's 34,474 kPa (5.12.9.4.2); timber 10,342,136 kPa, Southern Pine's and Douglas Fir's (Table 8.4.1.4-1).
driving_conditionstext · optional · one of: severe, good · default "severe"
How the steel pile is driven, for its structural resistance in axial compression under AASHTO (6.5.4.2): severe, where driving may damage it and a pile tip (a shoe) is used, φc 0.50 for an H-pile and 0.60 for a pipe; good, where no tip is needed, 0.60 and 0.70. Refused in free mode, which takes no φ.
depth_to_fixitynumber · optional · ≥ 0
Optional, under a design code: the depth to fixity below the scour line after a flood's scour (m), from the designer's soil–structure analysis: with the length the scour leaves without soil, the length the pile may buckle over (AASHTO 10.7.3.13.4). Empty, Davisson and Robinson's for preliminary design (C10.7.3.13.4), by the soil at the scour line: a clay's Su, a sand's k; on rock, the designer's, or the axial resistance after the scour isn't computed. Refused in free mode, which designs no section.
h_pile
pile_typetext · required · = "h_pile"
Driven steel H-pile: a low-displacement pile.
sectiongroup · required
A steel H section, from Das & Sivakugan's Table 12.1a checked against FHWA GEC 12's Fig. 8-2 (h_pile_sections). Its toe bears with the soil plug between the flanges (area d · bf) and its shaft is the box around it, 2 (d + bf) (Figure 12.16).
shapetext · required · = "h"
designationtext · required · one of: HP200x53, HP250x85, HP250x62, HP310x125, HP310x110, HP310x93, HP310x79, HP330x149, HP330x129, HP330x109, HP330x89, HP360x174, HP360x152, HP360x132, HP360x108
The H-pile section, HP depth (mm) × weight (kg/m) (Das & Sivakugan, Table 12.1a, checked against FHWA GEC 12, Fig. 8-2): its depth, flange width and moments of inertia. In US units it's called by its US designation, HP depth (in.) × weight (lb/ft), each section's us_designation in x-catalog: the HP 12x74 is HP310x110.
bending_axistext · optional · one of: strong, weak · default "strong"
The axis a lateral load bends it about: the strong one (x), the load against the flanges, or the weak one (y).
lengthnumber · required · > 0 · ≤ 300
Length of the pile, from its head to its toe (m).
head_depthnumber · optional · ≥ 0 · default 0
Depth of the pile's head below the ground (m): 0 with the heads at the surface, deeper under a buried cap.
head_fixitytext · optional · one of: free_head, fixed_head · default "free_head"
Under a lateral load: free_head, the head turns; or fixed_head, held by a cap that doesn't let it turn (Das & Sivakugan's restrained head, section 12.19).
yield_strengthnumber · optional · > 0 · default 345000
Yield strength of the steel F_y (kPa): 345 MPa, ASTM A572 Grade 50, as H-piles are made today (FHWA NHI-16-009, section 6.3 and Table 8-2). M_y = F_y S, at first yield (Das & Sivakugan, Eq. 12.116).
pile_modulusnumber · optional · > 0
Optional: modulus of elasticity Ep of the pile (kPa), for a drilled shaft's settlement (AASHTO 10.8.2.2.2), a pile's elastic compression and a lateral load. Empty, AASHTO's for its material: steel 199,947,962 kPa (6.4.1); concrete Ec by Eq. 5.4.2.4-1 from f′c, a drilled shaft's own or 27,579 kPa, a precast pile's 34,474 kPa (5.12.9.4.2); timber 10,342,136 kPa, Southern Pine's and Douglas Fir's (Table 8.4.1.4-1).
driving_conditionstext · optional · one of: severe, good · default "severe"
How the steel pile is driven, for its structural resistance in axial compression under AASHTO (6.5.4.2): severe, where driving may damage it and a pile tip (a shoe) is used, φc 0.50 for an H-pile and 0.60 for a pipe; good, where no tip is needed, 0.60 and 0.70. Refused in free mode, which takes no φ.
depth_to_fixitynumber · optional · ≥ 0
Optional, under a design code: the depth to fixity below the scour line after a flood's scour (m), from the designer's soil–structure analysis: with the length the scour leaves without soil, the length the pile may buckle over (AASHTO 10.7.3.13.4). Empty, Davisson and Robinson's for preliminary design (C10.7.3.13.4), by the soil at the scour line: a clay's Su, a sand's k; on rock, the designer's, or the axial resistance after the scour isn't computed. Refused in free mode, which designs no section.
precast_concrete
pile_typetext · required · = "precast_concrete"
Driven precast concrete: a high-displacement pile.
sectionone of · required
circular
shapetext · required · = "circular"
diameternumber · required · > 0
Outside diameter (m).
square
shapetext · required · = "square"
sidenumber · required · > 0
Side of the square section (m).
lengthnumber · required · > 0 · ≤ 300
Length of the pile, from its head to its toe (m).
head_depthnumber · optional · ≥ 0 · default 0
Depth of the pile's head below the ground (m): 0 with the heads at the surface, deeper under a buried cap.
head_fixitytext · optional · one of: free_head, fixed_head · default "free_head"
Under a lateral load: free_head, the head turns; or fixed_head, held by a cap that doesn't let it turn (Das & Sivakugan's restrained head, section 12.19).
yield_momentnumber · optional · > 0
Optional, under a design code: the pile's yield moment M_y (kN·m), from its section and its reinforcement, for a lateral load: with it, the bending check. Refused in free mode, which has no load or resistance factors to design a section by.
pile_modulusnumber · optional · > 0
Optional: modulus of elasticity Ep of the pile (kPa), for a drilled shaft's settlement (AASHTO 10.8.2.2.2), a pile's elastic compression and a lateral load. Empty, AASHTO's for its material: steel 199,947,962 kPa (6.4.1); concrete Ec by Eq. 5.4.2.4-1 from f′c, a drilled shaft's own or 27,579 kPa, a precast pile's 34,474 kPa (5.12.9.4.2); timber 10,342,136 kPa, Southern Pine's and Douglas Fir's (Table 8.4.1.4-1).
timber
pile_typetext · required · = "timber"
Driven timber: a high-displacement pile.
sectiongroup · required
shapetext · required · = "circular"
diameternumber · required · > 0
Outside diameter (m).
lengthnumber · required · > 0 · ≤ 300
Length of the pile, from its head to its toe (m).
head_depthnumber · optional · ≥ 0 · default 0
Depth of the pile's head below the ground (m): 0 with the heads at the surface, deeper under a buried cap.
head_fixitytext · optional · one of: free_head, fixed_head · default "free_head"
Under a lateral load: free_head, the head turns; or fixed_head, held by a cap that doesn't let it turn (Das & Sivakugan's restrained head, section 12.19).
yield_momentnumber · optional · > 0
Optional, under a design code: the pile's yield moment M_y (kN·m), from its section and its reinforcement, for a lateral load: with it, the bending check. Refused in free mode, which has no load or resistance factors to design a section by.
pile_modulusnumber · optional · > 0
Optional: modulus of elasticity Ep of the pile (kPa), for a drilled shaft's settlement (AASHTO 10.8.2.2.2), a pile's elastic compression and a lateral load. Empty, AASHTO's for its material: steel 199,947,962 kPa (6.4.1); concrete Ec by Eq. 5.4.2.4-1 from f′c, a drilled shaft's own or 27,579 kPa, a precast pile's 34,474 kPa (5.12.9.4.2); timber 10,342,136 kPa, Southern Pine's and Douglas Fir's (Table 8.4.1.4-1).
groupgroup · optional
Piles in a rectangular grid; 1 × 1 is a single pile.
count_xinteger · optional · ≥ 1 · ≤ 50 · default 1
Piles along x.
count_yinteger · optional · ≥ 1 · ≤ 50 · default 1
Piles along y.
spacingnumber · optional · > 0 · default 1
Centre-to-centre spacing (m), along x, and along y too unless spacing_y says otherwise.
spacing_ynumber · optional · > 0
Centre-to-centre spacing along y (m), when it differs.
loadgroup · required
deadgroup · required
The permanent part: the structure's own weight and what stays on it.
verticalnumber · optional · default 0
Total vertical load on the pile, or on the whole group at its piles' heads (kN), the cap's own weight in the dead part: positive down, negative up (an uplift); 0 for a pile under a lateral load only.
horizontalnumber · optional · ≥ 0 · default 0
Lateral load H (kN): at a single pile's head, or the whole group's total at its cap, along x, the rows sharing it by their p-multipliers. Its deflection and its moments, the pile a beam-column on p–y curves under its axial load too (AASHTO 10.7.3.12, 10.7.2.4; FHWA GEC 9).
head_momentnumber · optional · default 0
A single pile's moment M_g at its head (kN·m), positive when it bends the pile the way the lateral load does: H a height e above the head is M_g = H e. Refused for a fixed head, whose cap takes the moment it needs, and for a group, whose moment is its cap's (cap_moment_x).
cap_moment_xnumber · optional · default 0
A group's moment at its piles' heads that moves its load off centre along x (kN·m): positive loads the piles at +x more, M = V e_x. Each pile then takes V/n + M x / Σx² (AASHTO C10.7.3.10, the rigid cap; FHWA GEC 12, Eq. 8-79). Refused for a single pile, whose moment is its head moment.
cap_moment_ynumber · optional · default 0
A group's moment at its piles' heads that moves its load off centre along y (kN·m): positive loads the piles at +y more, M = V e_y. Refused for a single pile, and for a group with one pile across y.
livegroup · optional
Optional: the part that comes and goes (occupancy, traffic, storage). Free mode adds it to the dead part; a code with load factors factors each its own way.
verticalnumber · optional · default 0
Total vertical load on the pile, or on the whole group at its piles' heads (kN), the cap's own weight in the dead part: positive down, negative up (an uplift); 0 for a pile under a lateral load only.
horizontalnumber · optional · ≥ 0 · default 0
Lateral load H (kN): at a single pile's head, or the whole group's total at its cap, along x, the rows sharing it by their p-multipliers. Its deflection and its moments, the pile a beam-column on p–y curves under its axial load too (AASHTO 10.7.3.12, 10.7.2.4; FHWA GEC 9).
head_momentnumber · optional · default 0
A single pile's moment M_g at its head (kN·m), positive when it bends the pile the way the lateral load does: H a height e above the head is M_g = H e. Refused for a fixed head, whose cap takes the moment it needs, and for a group, whose moment is its cap's (cap_moment_x).
cap_moment_xnumber · optional · default 0
A group's moment at its piles' heads that moves its load off centre along x (kN·m): positive loads the piles at +x more, M = V e_x. Each pile then takes V/n + M x / Σx² (AASHTO C10.7.3.10, the rigid cap; FHWA GEC 12, Eq. 8-79). Refused for a single pile, whose moment is its head moment.
cap_moment_ynumber · optional · default 0
A group's moment at its piles' heads that moves its load off centre along y (kN·m): positive loads the piles at +y more, M = V e_y. Refused for a single pile, and for a group with one pile across y.
earthquakegroup · optional
Optional: the earthquake's force effects at the heads (EQ), for Extreme Event I (AASHTO 10.7.4, 10.8.4; Table 3.4.1-1): what the bridge's seismic analysis gives the foundation, on top of the dead and the live parts.
verticalnumber · optional · default 0
Total vertical load on the pile, or on the whole group at its piles' heads (kN), the cap's own weight in the dead part: positive down, negative up (an uplift); 0 for a pile under a lateral load only.
horizontalnumber · optional · ≥ 0 · default 0
Lateral load H (kN): at a single pile's head, or the whole group's total at its cap, along x, the rows sharing it by their p-multipliers. Its deflection and its moments, the pile a beam-column on p–y curves under its axial load too (AASHTO 10.7.3.12, 10.7.2.4; FHWA GEC 9).
head_momentnumber · optional · default 0
A single pile's moment M_g at its head (kN·m), positive when it bends the pile the way the lateral load does: H a height e above the head is M_g = H e. Refused for a fixed head, whose cap takes the moment it needs, and for a group, whose moment is its cap's (cap_moment_x).
cap_moment_xnumber · optional · default 0
A group's moment at its piles' heads that moves its load off centre along x (kN·m): positive loads the piles at +x more, M = V e_x. Each pile then takes V/n + M x / Σx² (AASHTO C10.7.3.10, the rigid cap; FHWA GEC 12, Eq. 8-79). Refused for a single pile, whose moment is its head moment.
cap_moment_ynumber · optional · default 0
A group's moment at its piles' heads that moves its load off centre along y (kN·m): positive loads the piles at +y more, M = V e_y. Refused for a single pile, and for a group with one pile across y.
live_load_factornumber · optional · ≥ 0 · ≤ 1 · default 0.5
γEQ, the live load's factor at Extreme Event I, by AASHTO only (Table 3.4.1-1): the share of the traffic on the bridge during the earthquake, project-specific; 0.5 by Turkstra's rule (C3.4.1). Free mode takes the live load whole.
lateral_loadingtext · optional · one of: static, cyclic · default "static"
The lateral load once, or repeated (waves, wind, traffic): cyclic loading softens the p–y curves (FHWA GEC 9, App. A).
load_cyclesinteger · optional · ≥ 1
Optional: how many times a cyclic lateral load comes, for a stiff clay without free water (Welch and Reese, FHWA GEC 9, App. A.3).
soilgroup · required
stratalist · required · 1–50 items
Top down from the ground surface; the last stratum may leave its thickness out (it extends down); given, the profile ends at its bottom, the piles' toe inside it. A rock ends the profile: the pile may rest on it or enter it.
Each item is one of:
drainedSand, or clay in the long term, by its friction angle.
thicknessnumber · optional · > 0 · ≤ 1000
Thickness (m), at most 1000 (app.application.bounds).
unit_weightnumber · optional · > 0
Unit weight γ (kN/m³). Required where the pile's methods take the stresses (the methods from the strata's strength, the drilled shaft, the settlement). Without a measurement, AASHTO's traditional values (Table 3.5.1-1): a compacted sand, silt or clay 18.9; a loose sand, silt or gravel 15.7; a soft clay 15.7; a rolled gravel 22.0.
saturated_unit_weightnumber · optional · > 0
Saturated unit weight γsat (kN/m³), at least γ and more than water's 9.81. Required where the stratum reaches below the water table.
soil_typetext · required · one of: gravel, sand, silty_sand, clayey_sand, silt, clay, rockfill
What the soil is: gravel, sand (clean, fine to coarse, or slightly silty), silty sand, clayey sand, silt or clay; or a quarried rock fill. Each method reads it to know whether it's for this soil (a sand's methods, a clay's), and nothing is assumed without it. A drained stratum may be any type (a clay in the long term, by c' and φ'); an undrained one is a clay or a silt.
preconsolidation_pressurenumber · optional · > 0
Optional: preconsolidation pressure σ'c (kPa), the stratum's stress history: a drilled shaft's β takes a sand's (AASHTO 10.8.3.5.2b), and its consolidation takes it. Empty, a drilled shaft takes it from the stratum's N60 (AASHTO Eqs. 10.8.3.5.2b-4 and -5), or without one takes the sand normally consolidated, as everything else does.
behaviortext · required · = "drained"
friction_anglenumber · optional · > 0 · < 90
Friction angle φ' (deg). Required where the pile's method takes it (the shaft and the toe in sand, the p–y curves). Under AASHTO a drilled shaft's side takes a sand's φ′ from its N60 where it gives one (Eq. 10.8.3.5.2b-3), not this one.
spt_n60number · optional · > 0
Optional: the stratum's SPT blow count N60 (blows/ft), corrected for the hammer's energy only (N60 = N ER/60): the average of the readings in the stratum, never across strata (AASHTO 10.4.6.1). A drilled shaft reads it: its tip in sand takes qp = 57.46 N60 kPa, N60 at most 50 (AASHTO 10.8.3.5.2c), N60 the mean of the sand from the tip down 2D, each stratum's by its thickness there (Brown et al. 2010, Eq. 13-14), so where a thick stratum's N60 changes with depth, split it at the tip; the sand's σ′p comes from it where σ′p isn't given (AASHTO Eqs. 10.8.3.5.2b-4 and -5); and under AASHTO the side's φ′ comes from it, φ′ = 27.5 + 9.2 log (N1)60 (Eq. 10.8.3.5.2b-3), (N1)60 = N60 (101.3 kPa/σ′v)^0.5, at most 2 N60, at the stratum's middle along the shaft (Brown et al. 2010, Eq. 3-2). Required where a drilled shaft's tip rests in the stratum, where the stratum lies within 2D below a tip in sand, or where it starts less than 1.5B below a tip (10.8.3.5.3). A pile group reads it too: a gravel, sand, silty sand or silt below its equivalent footing, where the footing's load reaches, settles by Hough's method (AASHTO 10.7.2.3.2, 10.6.2.4.2b), its N60 corrected for the overburden at each layer, (N1)60 = CN N60 (Eq. 10.4.6.2.4-3); without it, the group has no settlement of its own.
subgrade_gradientnumber · optional · > 0
Optional: k (kN/m³), the sand's subgrade modulus rising with depth, k z the initial slope of its p–y curve under a lateral load (Reese et al. 1974, FHWA GEC 9, App. A), and the nh of Davisson and Robinson's depth to fixity at a flood's scour line (AASHTO C10.7.3.13.4). Empty, AASHTO's nh by the sand's consistency from its φ′, dry or moist above the water table and submerged below it (Table C10.4.6.3-2).
consolidationgroup · optional
Optional, for a group, in a silt or a clay: with these, the stratum's consolidation under the group is computed, below its equivalent footing at 2L/3 (AASHTO 10.7.2.3.1).
compression_indexnumber · required · > 0
Compression index Cc, from one-dimensional consolidation tests (AASHTO 10.4.6.3).
swelling_indexnumber · optional · > 0
Swelling index Cs. Required with a preconsolidation pressure above the stratum's σ'o.
initial_void_rationumber · required · > 0
Initial void ratio eo, at the stratum's initial vertical effective stress (AASHTO 10.6.2.4.3), from the consolidation test.
coefficient_of_consolidationnumber · optional · > 0
Optional: coefficient of consolidation cv (m²/year), for how long the stratum takes; from 1 for a low permeability clay to 100 for an overconsolidated sandy one (Das & Sivakugan, section 2.16). It drains through the faces it shares with a drained soil or the ground surface.
rockRock below the soil: a pile may rest on it or enter it (AASHTO
10.7.3.2, 10.8.3.5.4), and a rock whose qu is 10 to 100 ksf is a
cohesive intermediate geomaterial (10.8.3.5.5; Brown et al. 2010,
§13.2). Each field is asked for where the pile's method takes it
(deep_foundation_rock).
thicknessnumber · optional · > 0 · ≤ 1000
Thickness (m), at most 1000 (app.application.bounds).
behaviortext · required · = "rock"
unit_weightnumber · optional · > 0
Unit weight γ (kN/m³). Required where a drilled shaft's tip in jointed rock takes σ′v at its base (AASHTO Eq. 10.8.3.5.4c-3) and the shaft enters the rock.
saturated_unit_weightnumber · optional · > 0
Saturated unit weight γsat (kN/m³), at least γ and more than water's 9.81. Required where that σ′v reaches below the water table.
uniaxial_compressive_strengthnumber · optional · > 0
Uniaxial compressive strength qu of the intact rock (kPa), from unconfined compression tests on cores (AASHTO 10.4.6.4). Required where the pile reaches the rock. From 479 to 4,788 kPa the rock is a cohesive intermediate geomaterial, a clay shale or a mudstone (AASHTO C10.8.2.2.3): a drilled shaft's tip on it is the rock's, and its side in it isn't counted.
joint_conditiontext · optional · one of: closed, open_or_gouge_filled
The rock's joints: closed (intact or tightly jointed, no compressible or gouge-filled seams), or open or filled with gouge. Required where a drilled shaft's tip takes it (AASHTO 10.8.3.5.4c).
geological_strength_indexnumber · optional · ≥ 0 · ≤ 100
GSI of the rock mass (AASHTO Figs. 10.4.6.4-1 and -2). Required where a drilled shaft's tip is on jointed rock (Hoek–Brown, AASHTO Eq. 10.8.3.5.4c-2).
intact_rock_constantnumber · optional · > 0
mi, the Hoek–Brown constant of the intact rock, by its lithology (AASHTO Table 10.4.6.4-1: sandstone 17, shale 6, limestone 8 to 12, granite 32). Required with the GSI.
disturbance_factornumber · optional · ≥ 0 · ≤ 1 · default 0
Hoek–Brown's disturbance factor D, from 0 (undisturbed) to 1 (highly disturbed), for the disturbance the rock's removal causes (AASHTO 10.4.6.4, Eqs. 10.4.6.4-2 to -4): toward 0 where a shaft is cored, toward 1 where it's blasted, between them with a down-the-hole hammer (C10.4.6.4). 0 by default.
hard_rockyes or no · optional · default false
Hard rock, which a driven pile can't penetrate: it's driven to it and stops on it, and its nominal resistance is the pile's structural one, with φ for severe driving (AASHTO 10.7.3.2.3). Off, a rock the pile can be driven into, which AASHTO treats as soil (10.7.3.2.2): a driven pile's toe on it isn't computed, the stratum given as a soil instead. AASHTO draws no line by strength (GEC 12 §7.2.1.4: the classifications put it between 9,576 and 47,880 kPa of qu); the designer says, from the driving. Driven piles only.
undrainedClay in the short term, by its undrained strength.
thicknessnumber · optional · > 0 · ≤ 1000
Thickness (m), at most 1000 (app.application.bounds).
unit_weightnumber · optional · > 0
Unit weight γ (kN/m³). Required where the pile's methods take the stresses (the methods from the strata's strength, the drilled shaft, the settlement). Without a measurement, AASHTO's traditional values (Table 3.5.1-1): a compacted sand, silt or clay 18.9; a loose sand, silt or gravel 15.7; a soft clay 15.7; a rolled gravel 22.0.
saturated_unit_weightnumber · optional · > 0
Saturated unit weight γsat (kN/m³), at least γ and more than water's 9.81. Required where the stratum reaches below the water table.
soil_typetext · required · one of: clay, silt
What the soil is: a clay or a silt, the soils taken undrained in the short term (a granular soil is always drained, Das & Sivakugan, section 2.22: make the stratum drained).
preconsolidation_pressurenumber · optional · > 0
Optional: preconsolidation pressure σ'c (kPa), the stratum's stress history: its consolidation takes it, and a clay's OCR for a pile's shaft. Empty, normally consolidated.
behaviortext · required · = "undrained"
undrained_shear_strengthnumber · optional · > 0
Undrained shear strength cu (kPa). Required where the pile's method takes it (the shaft and the toe in clay).
strain_at_half_strengthnumber · optional · > 0 · < 0.2
Optional: ε50, the axial strain at half the peak deviator stress of a triaxial test, for the clay's p–y curve; by default by c_u, 0.02 for a soft clay to 0.004 for a hard one (FHWA GEC 12, Table 7-21).
consolidationgroup · optional
Optional, for a group, in a silt or a clay: with these, the stratum's consolidation under the group is computed, below its equivalent footing at 2L/3 (AASHTO 10.7.2.3.1).
compression_indexnumber · required · > 0
Compression index Cc, from one-dimensional consolidation tests (AASHTO 10.4.6.3).
swelling_indexnumber · optional · > 0
Swelling index Cs. Required with a preconsolidation pressure above the stratum's σ'o.
initial_void_rationumber · required · > 0
Initial void ratio eo, at the stratum's initial vertical effective stress (AASHTO 10.6.2.4.3), from the consolidation test.
coefficient_of_consolidationnumber · optional · > 0
Optional: coefficient of consolidation cv (m²/year), for how long the stratum takes; from 1 for a low permeability clay to 100 for an overconsolidated sandy one (Das & Sivakugan, section 2.16). It drains through the faces it shares with a drained soil or the ground surface.
water_tablegroup · optional
null when there is none.
depthnumber · required
Depth below the ground surface on its side (m); negative when the water stands above it.
downdraggroup · optional
Optional: the ground settles around the piles down to a depth, and drags them down (negative skin friction). Empty, it doesn't.
depthnumber · required · > 0
How deep the ground settles around the piles (m below the ground): the bottom of the deepest stratum that settles.
scourgroup · optional
Optional: what the floods take from the ground at the pile, the scour design flood's and the check flood's (AASHTO 2.6.4.4.4, 10.7.3.6). The strata stay what was there before.
design_floodgroup · required
The scour design flood's scour: the strength and service limit states take all of it, Extreme Event I half (AASHTO Table 2.6.4.4.4-1), each also without scour.
degradation_scournumber · optional · ≥ 0 · default 0
Long-term degradation of the streambed (m): the ground lowered across the channel, its weight gone from the effective stress below.
contraction_scournumber · optional · ≥ 0 · default 0
Contraction scour (m), below the degradation: across all or most of the channel, like the degradation, its weight gone from the effective stress below.
local_scournumber · optional · ≥ 0 · default 0
Local scour at the foundation (m), below the other two: the hole around the pile; its side resistance and lateral support are gone, the effective stress below it as before (FHWA GEC 12, §7.2.9).
check_floodgroup · optional
Optional: the scour check flood's scour, for Extreme Event II (AASHTO Table 2.6.4.4.4-1; 10.7.4).
degradation_scournumber · optional · ≥ 0 · default 0
Long-term degradation of the streambed (m): the ground lowered across the channel, its weight gone from the effective stress below.
contraction_scournumber · optional · ≥ 0 · default 0
Contraction scour (m), below the degradation: across all or most of the channel, like the degradation, its weight gone from the effective stress below.
local_scournumber · optional · ≥ 0 · default 0
Local scour at the foundation (m), below the other two: the hole around the pile; its side resistance and lateral support are gone, the effective stress below it as before (FHWA GEC 12, §7.2.9).
designgroup · optional
The mode its checks are judged in, free or a design code, and the designer's limits. Empty, free mode.
codetext · optional · one of: free_mode, aashto_lrfd_10 · default "free_mode"
The mode the checks are judged in. free_mode: no design code; the methods are the designer's (each left by the data, or chosen), each check gives its unfactored factor of safety or its quantity, and only the checks the designer set a limit for (limits) have a verdict; the limits the codes and manuals ask come beside each check as references. aashto_lrfd_10: AASHTO LRFD Bridge Design Specifications, 10th edition (2024), load and resistance factor design, each check φRn/ΣγQ ≥ 1, with the methods the code admits.
limitsnumber · optional
Optional: the designer's limits, by the check's id (its factor of safety, or its settlement, deflection or eccentricity in m). In free mode, the only checks with a verdict; under a code, in place of the code's, and the answer says what the code asks.
resistance_factorsnumber · optional
Optional, with a code of load and resistance factors: the resistance factors φ the designer edited, by the check's id, in place of the code's.
load_modifiergroup · optional
With a code of load and resistance factors: the load modifier η = ηD ηR ηI on the strength limit state's factors (AASHTO 1.3.2.1 to 1.3.5), 1.00 each by default.
ductilitynumber · optional · ≥ 0.95 · default 1
ηD (AASHTO 1.3.3): 1.00 for conventional designs and details; 1.05 or more for nonductile components and connections; 0.95 or more where ductility-enhancing measures beyond the code's are specified.
redundancynumber · optional · ≥ 0.95 · default 1
ηR (AASHTO 1.3.4): 1.00 for conventional redundancy, and always for a footing or a pile, whose φ already accounts for it (10.5; another value is refused there, and a pile's φ for few elements under its support is redundancy_factor's); 1.05 or more for nonredundant members; 0.95 or more for exceptional redundancy.
importancenumber · optional · ≥ 0.95 · default 1
ηI (AASHTO 1.3.5): 1.00 for typical bridges; 1.05 or more for critical or essential bridges; 0.95 or more for relatively less important ones, as the Owner classifies them.
redundancy_factornumber · optional · > 0 · ≤ 1
Optional, with a code of load and resistance factors: r, the factor on the pile's φ at the strength limit state for few elements to share the load. Empty, AASHTO's: 0.8 for a single drilled shaft (10.5.5.2.4, "a single shaft supporting a bridge pier") and for a driven pile alone or in a group of fewer than five (C10.5.5.2.3, "small pile groups"), 1.0 otherwise. Set 1.0 where the modeled pile or shaft is one of several under its support (a pier on three shafts, a larger group of piles), as FHWA's examples take it. A φ edited for the whole pile (resistance_factors) takes no r.