The structural design stage
Rischio's structural design stage: each part's forces by limit state, its bars proposed and checked by AASHTO LRFD, its cross-section and its report chapter.
The structural design comes after the geotechnics. Once the model is calculated, the forces in the structure are known, and this stage designs the parts that carry them: a cantilever wall’s stem, toe and heel, and a pile’s section. It’s optional: a model without it still has its calculation report, with the geotechnics alone. The theory is in Structural design of a cantilever wall and in a pile’s Structural resistance.
Where it is
In the list of elements on the left, Structural design comes after the groups of the geotechnics, in a retaining wall and in piles. Before the model is calculated it shows dimmed, with Calculate to see the forces in each part. Once it’s calculated it’s live, even where a geotechnical check fails.
Its rows are the structure’s parts, each with its bars and its mark, or without bars:
- a cantilever wall’s Stem, Toe and Heel, those it has (an L wall has no toe), then Materials: the concrete’s f′c, the bars’ fy, their standard (A615, or A706) and the exposure crack control holds them to;
- a pile’s Pile, its section, which takes bars as a drilled shaft (30 #10).
A row opens its page where Properties is, and the drawing then shows the structural stage: the forces along each part, and its bars.
The forces
A part’s page opens with its forces under the limit state the diagrams are drawn under, where its checks read them: Forces · Strength I · Mu 149.1 kN·m/m · Vu 90.3 kN/m, at the stem’s base. A pile gives its largest moment, shear and axial load, each with its depth (Mu at 1.90 m deep · Vu at 6.30 m deep · Pu at the head).
Under Diagrams, in Results or with a part open, the drawing has the moment and the shear along the stem, the toe and the heel, or the moment, the shear and the axial load down a pile, one set of loads at a time, chosen beside the group’s title: a wall’s at Strength I, Service I and, with an earthquake, Extreme Event I; a pile’s at Strength I and, where the model has them, Extreme Event I and II. In free mode they’re unfactored, with every load at 1.00. Where a wall’s part has bars, its factored flexural resistance φMn is drawn beside its moment.
Design the reinforcement
In a cantilever wall, Design the reinforcement, on the group’s title, proposes each part’s bars from its forces. Of the standard bars and spacings that pass the part’s checks and detailing rules, it takes the fewest bars per metre whose steel stays within 15 % of the lightest layout’s: fewer bars, more widely spaced, are easier to place and to concrete around. It writes them as one step, calculates again, and says so with Undo. A part without bars offers its own Design, or says why no standard bar passes, such as a section too thin for its forces. Remove the reinforcement takes every part’s bars away and keeps the materials.
The proposal is a start: change any bar, and the checks are on yours. Design the reinforcement is on every plan; How to fix it, which brings a failing part’s bars closer, is part of Professional.
A drilled shaft’s cage is yours to give: on its page, switch on Reinforcement and give the number and size of its longitudinal bars, its spiral or hoops, and its cover.
A part’s page
A part’s page holds what you set, and its checks are in Results. Under its title, its own verdict (1 of 7 checks fail) leads to them with Results →. After its forces, the page has:
- its cross-section, to scale, as the report prints it: a wall’s part as a 1 m strip (1 ft in US units) at its critical section, with its thickness h, its bars at their spacing, their cover c and the depth d; a drilled shaft’s circle with its cage, its spiral or hoops, its cover and D; a steel H-pile by its catalog shape, a pipe pile’s ring;
- its bars: each chosen by its designation, #3 to #11 (ASTM A615 and A706), with its diameter in the model’s units, then its spacing and its clear cover. Each limit shows under the field it limits, red while it fails: ≤ 343.1 mm, crack control under a spacing, ρl ≥ 0.914 %, minimum steel under a shaft’s bars.
On the drawing, the selected part’s bars sit at their cover, and the cover’s handle drags it.
In Results
Where the model has a structure, Results lists its checks by stage: Geotechnics, then Structural design, each with the check that Governs design. A part reads as one line: its strength check closest to its limit, its value against its limit and its bar, named under it (Least steel in the heel), and the part’s mark. A rule of detailing never governs: when one fails beside passing strength checks, the line says so in red under the bar (1 of 3 detailing rules fail). Before a part has bars the line says Without bars, and in free mode Unfactored forces; those open the part’s page in Properties.
A click on a part with checks opens them, still in Results: How to fix it where one fails, its strength checks, each with its bar, and apart its detailing rules, met or not, with no bar (a wall’s bar spacing and cover; a shaft’s steel ratio, the number and size of its bars, its spiral’s volume ratio and the clear spacing between its bars). Edit its bars goes back to the part’s page in Properties. A check opens its page under the part’s, with every step; the arrows go through that part’s checks, and Esc goes back to the part, then to every check.
In free mode
Free mode designs no structure: reinforced concrete and steel are designed by strength, with factored loads and resistance factors φ, and free mode has neither. The stage gives each part’s forces, unfactored (M 94.6 kN·m/m), and their diagrams. The reinforcement, or a steel pile’s structural resistance, shows dimmed, Under a design code, with Change the design code. What only the structural checks read stays in the model, set aside, and comes back under a code.
In the report
The calculation report gives the stage its chapters after the geotechnics, numbered as theirs. The first gives the forces (Forces in the stem, the toe and the heel, Forces in the pile): their diagrams under each limit state, Strength I and Service I, and Extreme Event I with an earthquake, and the largest values, with where they act; in free mode, unfactored. Under a design code, Reinforcement follows, with the parts’ bars in a table and their cross-sections, then a chapter for each part (13 Stem, 14 Toe, 15 Heel; 12 Pile), its checks in sections of their own, strength first and then detailing (13.1 Bending, 13.4 Bar spacing), step by step.