Normal and critical flow
Normal depth, where Manning's discharge summed over the parts of the section equals Q; critical depth, Froude number and specific energy.
The section is divided into parts at the main channel’s banks, where the overbanks’ roughness changes and where dry ground keeps the water apart, and each carries its own share of the discharge.
Normal depth by Manning
At any water level, Manning’s equation in SI units gives each part’s discharge, and the section carries their sum:
The vertical lines between parts are not wetted perimeter. Within a part, the conveyance grows as the water rises. Where the water tops ground that kept two of its areas apart, the two become one part, which carries less than they did apart, and the discharge steps down there. A bench in the bed or a terrace in an overbank isn’t divided either, and there the discharge can drop as the water first spreads over it. Either way more than one depth can carry the same , and Rischio warns of it (see the rating curve).
The normal depth is the depth at which this discharge equals , the lowest one where more than one does: the first the water reaches as it rises. Brent’s method finds it between the bed and the lower bank, inside the first stretch of levels that reaches : it brackets the root and needs no derivative, so kinks in the section don’t stall it. The tolerance is about m.
Critical depth and the Froude number
In a section that flows as one part, the Froude number, , uses the hydraulic depth , not the flow depth, and the energy coefficient (Chow’s criterion for critical flow). Depth and hydraulic depth are equal in a rectangle; in other shapes, is smaller. Where the flow spreads over the main channel and its overbanks, changes with the depth, and the Froude number is Blalock and Sturm’s (1981), from the specific energy below, 1 where is least:
is subcritical flow, supercritical and critical. raises a near-critical warning (USACE EM 1110-2-1601, paragraph 2-2d(1)(b)).
weighs the velocity head of a section whose parts flow at different velocities, over the left overbank, the main channel and the right overbank (HEC-RAS, “Evaluation of the Mean Kinetic Energy Head”; Chow, Eq. 2-3), with each one’s conveyance; it is 1 in a section that flows as one part:
The critical depth is the minimum of the specific energy, , between the bed and the lower bank, with at each level. Rischio finds every minimum (the energy at 200 levels and at every vertex’s elevation, each minimum refined) and takes the one with the least energy, as HEC-RAS does (“Critical Depth Determination”). Where the water tops a levee, or ground that kept two of its areas apart, steps; a minimum at that step is the step’s, not the flow’s, since still falls as the water reaches it (). HEC-RAS passes over a minimum at a levee’s or an ineffective area’s break for the next one, and Rischio does the same with a step’s, taking one only if every minimum is at a step. The others are beside it in the Results tab, and a note says so. With the critical depth come its flow’s velocity, , and hydraulic depth, . With no minimum below the bank, there is no critical depth to report.
Specific energy
The specific energy is measured from the bed: its is the normal depth, not an elevation, so is not the total head. The velocity head is , with the mean velocity and the section’s at the normal depth.