Bank-full capacity and the rating curve
Bank-full capacity, the limit of the capacity check; the freeboard the water leaves below the lower bank; and the rating curve, from the bed to that bank.
Both use Manning’s equation, with the section divided into parts at the main channel’s banks and where the overbanks’ roughness changes.
Bank-full capacity
The water can rise only to the lower bank, each bank the highest point between the bed and that end of the section; above it, it leaves the section. is Manning’s discharge with the water at that level. The check compares discharges because a depth above the banks has no meaning: the section ends there. When , nothing above the banks is reported, not even the normal depth or the regime.
Freeboard
The freeboard is how far the water, at its normal depth, stays below the lower bank:
with the lower bank’s height above the bed. It’s checked against the freeboard the designer requires, , a depth in metres. Without one it has no verdict of its own and the bank-full capacity judges alone; no usual value stands beside it. When the discharge overtops the section, there is no normal depth to measure it from.
Rating curve
The rating curve is Manning’s discharge at 21 water levels, equally spaced from m above the bed to the lower bank; the last one gives . With the section divided at the main channel’s banks, the discharge grows with the water level. A bench in the bed or a terrace in an overbank isn’t divided, and there the discharge can still drop as the water first spreads over it, its wetted perimeter growing much faster than its area: Rischio warns of it.