The limits every check is held to by default, tool by tool: factors of safety, the middle third, settlement and bank-full capacity.

Every check compares a value with a limit. These are Rischio’s defaults. Each result shows its margin to the limit, and the check with the smallest margin governs the model.

Retaining walls

CheckLimit

Overturning

The wall rotating about its toe

FS=ΣMRΣMOFS = \frac{\Sigma M_R}{\Sigma M_O}

≥2.0\ge 2.0

Sliding

The wall pushed along its base

FS=RΣHFS = \frac{R}{\Sigma H}

≥1.5\ge 1.5

Bearing capacity

The ground under the base giving way

FS=quqmaxFS = \frac{q_u}{q_{max}}

≥3.0\ge 3.0

Eccentricity

The resultant inside the middle third of the base

ee

≤B6\le \frac{B}{6}

Gabion levels

Each level overturning or sliding on the one below

FS=ΣMRΣMO,  RΣHFS = \frac{\Sigma M_R}{\Sigma M_O},\; \frac{R}{\Sigma H}

≥2.0,  ≥1.5\ge 2.0,\; \ge 1.5

Footings

CheckLimit

Bearing capacity

The ground under the footing giving way

FS=quqmaxFS = \frac{q_u}{q_{max}}

≥3.0\ge 3.0

Eccentricity along the width

The load inside the middle third, across the width

eBe_B

≤B6\le \frac{B}{6}

Eccentricity along the length

The load inside the middle third, along the length

eLe_L

≤L6\le \frac{L}{6}

Settlement

The footing's elastic settlement, at its centre

SeS_e

≤25 mm\le 25 \text{ mm}

Piles

CheckLimit

Pile group

The group's axial capacity, as piles or as one block

FS=QgQFS = \frac{Q_g}{Q}

≥3.0\ge 3.0

Single pile

One pile's axial capacity against its load, when there's only one

FS=QuQFS = \frac{Q_u}{Q}

≥3.0\ge 3.0

Open channels

CheckLimit

Bank-full capacity

The discharge fits below the lower bank

QQ

≤Qbank\le Q_{bank}