FHWA GEC 10 (2010), Example 13-4 · Shaft in sand and gravel
Shaft in sand and gravel, Example 13-4 of Brown et al. (2010), solved in Rischio. Factored axial resistance, ΣφR: 1 408 kips (source: 1 403 kips).
SourceManual
Brown, D. A., Turner, J. P., & Castelli, R. J. (2010). Drilled Shafts: Construction Procedures and LRFD Design Methods (FHWA-NHI-10-016). Federal Highway Administration. Example 13-4, p. 13-32 to 13-37.
ID fhwa-nhi-10-016-13-4
Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.
The problem
What the source calculates: shaft resistance, RSN, toe resistance, RBN and factored axial resistance, ΣφR. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):
Source vs Rischio
| Source | Rischio | Difference | |
|---|---|---|---|
| Shaft resistance, RSN | 1 523 kips | 1 533 kips | +0.6 % |
| Toe resistance, RBN | 1 131 kips | 1 131 kips | 0.0 % |
| Factored axial resistance, ΣφR | 1 403 kips | 1 408 kips | +0.4 % |
Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.
As the manual does, the model takes the resistance factors without the 20 % cut AASHTO asks for when a single shaft supports a bridge pier.
How it's calculated
- Shaft resistance →How Rischio adds up a pile's shaft, stratum by stratum: a driven pile by Tomlinson's α in clay and Nordlund's method in sand, a drilled shaft by FHWA GEC 10.
- Equations →Every step of the calculation, in order.
- Piles in Rischio →The tool: what it checks, and its calculation report.
Nearest examples
- FHWA GEC 10 (2018), Example 10-1 and 10-3 · Drilled shaftFederal Highway Administration (2018): toe resistance, RBN
- FHWA-NHI-06-089, Example 9-2 · Precast pile in silty sandSamtani & Nowatzki (2006): ultimate capacity, Qu
- FHWA-NHI-16-064, Example D.10.1, 30 ft · H-pile in sandFederal Highway Administration (2016): nominal resistance, Rn