Rischio
Start free

DocsVerified examples

FHWA-NHI-16-064, Example D.21 · H-pile column after scour

H-pile column after scour, Example D.21 of Federal Highway Administration (2016), solved in Rischio and compared with the source's answers.

SourceManual

Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.21, p. 93–94.

ID fhwa-nhi-16-064-d21

Open in the studioA copy, in your accountOpen the PDF

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.

The problem

What the source calculates: nominal axial resistance at the design flood (Strength V), Pn, nominal axial resistance at the check flood (Extreme Event II), Pn and factored axial resistance at the design flood (Strength V), Pr. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure D-39, p. 98.

Source vs Rischio

SourceRischioDifference
Nominal axial resistance at the design flood (Strength V), Pn1 043 kips1 045 kips+0.2 %
Nominal axial resistance at the check flood (Extreme Event II), Pn999 kips1 001 kips+0.3 %
Factored axial resistance at the design flood (Strength V), Pr521 kips523 kips+0.3 %

Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.

The model carries the load on the most loaded pile (Tables D-58 to D-61): its permanent part as dead load, and the rest of its Service I load, the traffic and the cap's moments, which the manual doesn't separate, as live load. Rischio factors it at Strength I to 305 kips, on the safe side of the manual's Strength V, 257 kips, which takes the traffic at 1.35 and adds the wind.

How it's calculated

Nearest examples

Type to search: a method, a warning, a field…

↑↓ to move · ↵ to open · esc to close