FHWA-NHI-16-064, Example D.9 · H-pile structural resistance
H-pile structural resistance, Example D.9 of FHWA-NHI-16-064, solved in Rischio. Factored axial resistance, Pr: 546 kips (source: 544 kips).
SourceManual
Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.9, p. 21–22.
ID fhwa-nhi-16-064-d9
Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.
The problem
What the source calculates: nominal axial resistance, Pn and factored axial resistance, Pr. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):
Source vs Rischio
| Source | Rischio | Difference | |
|---|---|---|---|
| Nominal axial resistance, Pn | 1 088 kips | 1 093 kips | +0.4 % |
| Factored axial resistance, Pr | 544 kips | 546 kips | +0.4 % |
Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.
How it's calculated
- Structural resistance →How Rischio checks a pile as a structural member: steel by AASHTO Section 6, a drilled shaft with its cage by Section 5, in axial load, bending and shear.
- Equations →Every step of the calculation, in order.
- Piles in Rischio →The tool: what it checks, and its calculation report.
Nearest examples
- FHWA-NHI-16-064, Example D.10.1, 30 ft · H-pile in sandFederal Highway Administration (2016): nominal resistance, Rn
- FHWA-NHI-16-064, Example D.10.1, 45 ft · H-pile to gravelFederal Highway Administration (2016): shaft resistance, Rs
- FHWA-NHI-06-089, Example 9-2 · Precast pile in silty sandSamtani & Nowatzki (2006): ultimate capacity, Qu