FHWA-NHI-16-064, Example D.9 · H-pile structural resistance

H-pile structural resistance, Example D.9 of FHWA-NHI-16-064, solved in Rischio. Factored axial resistance, Pr: 546 kips (source: 544 kips).

SourceManual

Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.9, p. 21–22.

ID fhwa-nhi-16-064-d9

Open in the studioA copy, in your accountOpen the PDF

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.

The problem

What the source calculates: nominal axial resistance, Pn and factored axial resistance, Pr. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure D-7, p. 26.

Source vs Rischio

SourceRischioDifference
Nominal axial resistance, Pn1 088 kips1 093 kips+0.4 %
Factored axial resistance, Pr544 kips546 kips+0.4 %

Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.

How it's calculated