Das, Example 6.13 · Strip footing, eccentric inclined load

Strip footing, eccentric inclined load, Example 6.13 of Das, solved in Rischio. Inclined ultimate load per metre, Qu(ei): 589.56 kN/m (source: 589.95 kN/m).

SourceBook

Das, B. M., & Sivakugan, N. (2019). Principles of Foundation Engineering, SI edition, 9th ed. Cengage Learning. Example 6.13, p. 252.

ISBN 978-1-337-70503-5ID das-pfe9-6-13

Open in the studioA copy, in your accountBuy the book

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.

The problem

What the source calculates: inclined ultimate load per metre, Qu(ei). Its problem, as Rischio's editor opens it in free mode:

The model, as the editor draws it. In the source: Figure 6.34, p. 252.

Source vs Rischio

SourceRischioDifference
Inclined ultimate load per metre, Qu(ei)589.95 kN/m589.56 kN/m−0.1 %

Opened in the studio in free mode, with no limits set, the model gives each value without a verdict.

The book asks for the ultimate load, so it puts none on the footing; the model carries one with the book's eccentricity and inclination only so the tool runs, and its size doesn't move the ultimate load.

How it's calculated