FHWA GEC 11 (2023), Example C1 · MSE wall with geogrids
MSE wall with geogrids, Example C1 of Federal Highway Administration (2023), solved in Rischio. Largest reinforcement strain, εrein: 0.017 (source: 0.017).
SourceManual
Taylor, Collin, Boyle, Fishman & Han (2023). Design and Construction of Mechanically Stabilized Earth (MSE) Walls (FHWA-HIF-24-002). Federal Highway Administration. Example C1, p. C-37.
ID fhwa-hif-24-002-c1-geogrid
Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.
The problem
What the source calculates: rupture capacity/demand ratio at layers 9 to 12, CDR and largest reinforcement strain, εrein. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):
Source vs Rischio
| Source | Rischio | Difference | |
|---|---|---|---|
| Rupture capacity/demand ratio at layers 9 to 12, CDR | 2.18 | 2.18 | +0.2 % |
| Largest reinforcement strain, εrein | 0.017 | 0.017 | +0.6 % |
Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.
How it's calculated
- MSE walls →How Rischio checks an MSE wall: each layer's load by AASHTO's method for its reinforcement, its rupture and pullout, and the block outside.
- Equations →Every step of the calculation, in order.
- Retaining walls in Rischio →The tool: what it checks, and its calculation report.
Nearest examples
- FHWA GEC 11 (2023), Example C1 · MSE wall with steel stripsFederal Highway Administration (2023): pullout capacity/demand ratio at layer 8 (z = 18.75 ft) by the Simplified Method, CDR
- FHWA-HIF-17-004, Example 10.2.1 · Geosynthetic MSE wallLeshchinsky et al. (2016): allowable strength of the geosynthetic, Tal (the report's LTDS)
- FHWA-NHI-00-043, Example 4.6 · Steel strip wall, ASDElias et al. (2001): eccentricity, e