FHWA GEC 11 (2023), Example C1 · MSE wall with steel strips
MSE wall with steel strips, Example C1 of Federal Highway Administration (2023), solved in Rischio and compared with the source's answers.
SourceManual
Taylor, Collin, Boyle, Fishman & Han (2023). Design and Construction of Mechanically Stabilized Earth (MSE) Walls (FHWA-HIF-24-002). Federal Highway Administration. Example C1, p. C-2.
ID fhwa-hif-24-002-c1
Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.
The problem
What the source calculates: sliding capacity/demand ratio at Strength I (critical), CDR, factored pressure under the base at Strength I (maximum), σv, eccentricity at Strength I (critical), e and pullout capacity/demand ratio at layer 8 (z = 18.75 ft) by the Simplified Method, CDR. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):
Source vs Rischio
| Source | Rischio | Difference | |
|---|---|---|---|
| Sliding capacity/demand ratio at Strength I (critical), CDR | 1.94 | 1.94 | +0.1 % |
| Factored pressure under the base at Strength I (maximum), σv | 6.91 ksf | 6.90 ksf | −0.1 % |
| Eccentricity at Strength I (critical), e | 2.05 ft | 2.04 ft | −0.6 % |
| Pullout capacity/demand ratio at layer 8 (z = 18.75 ft) by the Simplified Method, CDR | 1.10 | 1.10 | +0.2 % |
Opened in the studio under AASHTO LRFD 10th (2024), the model fails at least one check.
The example's Simplified Method analysis, the one the model follows, puts a third strip per panel in its three lowest layers; the model can't hold it and keeps two in every layer, so those three fail Rischio's rupture check.
How it's calculated
- MSE walls →How Rischio checks an MSE wall: each layer's load by AASHTO's method for its reinforcement, its rupture and pullout, and the block outside.
- Equations →Every step of the calculation, in order.
- Retaining walls in Rischio →The tool: what it checks, and its calculation report.
Nearest examples
- FHWA GEC 11 (2023), Example C1 · MSE wall with geogridsFederal Highway Administration (2023): largest reinforcement strain, εrein
- FHWA-NHI-00-043, Example 4.6 · Steel strip wall, ASDElias et al. (2001): eccentricity, e