Rischio
Start free

DocsVerified examples

FHWA-NHI-16-064, Example D.10.2, D.13 · H-pile in uplift

H-pile in uplift, Example D.10.2, D.13 of FHWA-NHI-16-064, solved in Rischio. Nominal uplift resistance, Rs: 95.3 kips (source: 94.0 kips).

SourceManual

Hannigan, Rausche, Likins, Robinson & Becker (2016). Design and Construction of Driven Pile Foundations: Comprehensive Design Example (FHWA-NHI-16-064). Federal Highway Administration. Example D.10.2, D.13, p. 28, 51-52.

ID fhwa-nhi-16-064-north-abutment-uplift-28ft

Open in the studioA copy, in your accountOpen the PDF

Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.

The problem

What the source calculates: nominal uplift resistance, Rs. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):

The model, as the editor draws it. In the source: Figure D-7, p. 26.

Source vs Rischio

SourceRischioDifference
Nominal uplift resistance, Rs94.0 kips95.3 kips+1.3 %

Opened in the studio under AASHTO LRFD 10th (2024), the model passes every check.

The manual's shaft resistance comes from the DrivenPiles program, and Rischio reads Nordlund's coefficients off AASHTO's charts, so the two can differ by up to 2 %. The model carries the pull on a pile of the back row (Tables D-13 and D-14), which Rischio factors to 37.6 kips, where the manual's Strength I gives 46: the 28 ft pile holds either, as in the manual (Table D-16).

How it's calculated

Nearest examples

Type to search: a method, a warning, a field…

↑↓ to move · ↵ to open · esc to close