FHWA-NHI-07-071, Example 7.9 · Precast panel MSE wall
Precast panel MSE wall, Example 7.9 of Tanyu et al. (2008), solved in Rischio. Factored rupture resistance, φ Tal Rc: 3 403 lb/ft (source: 3 385 lb/ft).
SourceManual
Tanyu, B. F., Sabatini, P. J., & Berg, R. R. (2008). Earth Retaining Structures (FHWA-NHI-07-071). Federal Highway Administration. Example 7.9, p. 7-76.
ID fhwa-nhi-07-071-7-9
Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.
The problem
What the source calculates: factored rupture resistance, φ Tal Rc. Its problem, as Rischio's editor opens it under AASHTO LRFD 10th (2024):
Source vs Rischio
| Source | Rischio | Difference | |
|---|---|---|---|
| Factored rupture resistance, φ Tal Rc | 3 385 lb/ft | 3 403 lb/ft | +0.5 % |
Opened in the studio under AASHTO LRFD 10th (2024), the model fails at least one check.
The example checks only the top layer, and finds the strips too short there because it counts the traffic in the pullout demand, which its own text and AASHTO leave out; without it, that layer passes, as in Rischio. Rischio checks every layer: all the others fail pullout, and one also fails rupture.
How it's calculated
- MSE walls →How Rischio checks an MSE wall: each layer's load by AASHTO's method for its reinforcement, its rupture and pullout, and the block outside.
- Equations →Every step of the calculation, in order.
- Retaining walls in Rischio →The tool: what it checks, and its calculation report.
Nearest examples
- FHWA GEC 11 (2009), Example E1 · MSE wall, broken backfillBerg et al. (2009): pullout capacity/demand ratio at layer 2, CDR
- FHWA-NHI-00-043, Example 4.7 · Modular block geogrid wallElias et al. (2001): factor of safety for bearing capacity
- FHWA GEC 11 (2009), Example E3 · MSE wall, sloping backfillBerg et al. (2009): pressure under the base at Service I, σv