FHWA GEC 11 (2009), Example E3 · MSE wall, sloping backfill
MSE wall, sloping backfill, Example E3 of Berg et al. (2009), solved in Rischio. Pressure under the base at Service I, σv: 7.16 ksf (source: 7.16 ksf).
SourceManual
Berg, R. R., Christopher, B. R., & Samtani, N. C. (2009). Design and Construction of Mechanically Stabilized Earth Walls and Reinforced Soil Slopes, Volume II (FHWA-NHI-10-025). Federal Highway Administration. Example E3, p. E3-11.
ID fhwa-nhi-10-025-e3-backslope
Rischio isn't affiliated with the source's authors or publishers. If you hold its rights and want this example removed, write to hello@rischio.io.
The problem
What the source calculates: eccentricity at Service I, eL and pressure under the base at Service I, σv. Its problem, as Rischio's editor opens it in free mode:
Source vs Rischio
| Source | Rischio | Difference | |
|---|---|---|---|
| Eccentricity at Service I, eL | 2.61 ft | 2.61 ft | +0.1 % |
| Pressure under the base at Service I, σv | 7.16 ksf | 7.16 ksf | 0.0 % |
Opened in the studio in free mode, with no limits set, the model gives each value without a verdict.
The model opens without limits, so Rischio gives no verdict where the example finds its sliding, eccentricity and bearing checks within their limits.
How it's calculated
- MSE walls →How Rischio checks an MSE wall: each layer's load by AASHTO's method for its reinforcement, its rupture and pullout, and the block outside.
- Equations →Every step of the calculation, in order.
- Retaining walls in Rischio →The tool: what it checks, and its calculation report.
Nearest examples
- FHWA GEC 11 (2009), Example E1 · MSE wall, broken backfillBerg et al. (2009): pullout capacity/demand ratio at layer 2, CDR
- FHWA-NHI-07-071, Example 7.9 · Precast panel MSE wallTanyu et al. (2008): factored rupture resistance, φ Tal Rc
- FHWA-NHI-00-043, Example 4.7 · Modular block geogrid wallElias et al. (2001): factor of safety for bearing capacity